Loading...
HomeMy WebLinkAbout4/4/14 energyreview RES check Software Version 4.3.1 Compliance Certificate Project Title: KEN SCHULZ 2009 IECC Energy Code: Iowa City, Iowa Location: Single Family Construction Type: Bldg. faces 90 deg. from North Building Orientation: 11% Glazing Area Percentage: 6227 Heating Degree Days: 5 Climate Zone: Construction Site:Owner/Agent:Designer/Contractor: 465 Teton CircleJesse AllenMichael Untrauer Iowa City, IAAllen HomesUntrauer Drafting Service, Inc. Permit Date: MAR. 2014530-82382260 Shropshire Circle Coralville, IA 52241 319 430-0760 untrauer@gmail.com Passes using UA trade-off Compliance: 3.3% Better Than Code360348 Compliance: Maximum UA: Your UA: The % Better or Worse Than Code index reflects how close to comp It DOES NOT provide an estimate of energy use or cost relative t GrossCavityCont.GlazingUA AssemblyArea orR-ValueR-Valueor Door PerimeterU-Factor Ceiling: Flat Ceiling or Scissor Truss180938.00.054 Exterior Wall 1: Wood Frame, 16" o.c.52019.00.027 Orientation: Front Window 1: Vinyl Frame:Double Pane with Low-E300.3009 SHGC: 0.22 Orientation: Front Door 1: Solid390.1506 Orientation: Front Wall 2: Wood Frame, 16" o.c.52019.00.027 Orientation: Back Window 2: Vinyl Frame:Double Pane with Low-E670.30020 SHGC: 0.22 Orientation: Back Wall 3: Wood Frame, 16" o.c.58019.00.032 Orientation: Left Side Window 3: Vinyl Frame:Double Pane with Low-E450.30014 SHGC: 0.22 Orientation: Left Side Wall 4: Wood Frame, 16" o.c.58028.00.026 Orientation: Right Side Window 4: Vinyl Frame:Double Pane with Low-E350.30011 SHGC: 0.22 Orientation: Right Side Door 2: Glass200.1503 SHGC: 0.22 Orientation: Right Side Basement Wall 1: Solid Concrete or Masonry41613.00.023 Orientation: Front Wall height: 8.0' Depth below grade: 7.5' Insulation depth: 8.0' Basement Wall 2: Solid Concrete or Masonry40013.00.030 Project Title: KEN SCHULZReport date: 03/25/14 Data filename: C:\Users\Mike\Documents\drawings\REScheck\Jesse Allen 465 Teton ranch.rckPage 1 of 2 Orientation: Left Side Wall height: 8.0' Depth below grade: 4.0' Insulation depth: 8.0' Basement Wall 3: Solid Concrete or Masonry40013.00.030 Orientation: Right Side Wall height: 8.0' Depth below grade: 4.0' Insulation depth: 8.0' Basement Wall 4: Solid Concrete or Masonry41613.00.022 Orientation: Back Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Window 5: Vinyl Frame:Double Pane with Low-E460.30014 SHGC: 0.22 Orientation: Back Compliance Statement: The proposed building design described here is consistent with calculations submitted with the permit application. The proposed RES check Version 4.3.1 and to comply with the mandatory requirements lis check Inspection Checklist. Name - TitleSignatureDate Project Title: KEN SCHULZReport date: 03/25/14 Data filename: C:\Users\Mike\Documents\drawings\REScheck\Jesse Allen 465 Teton ranch.rckPage 2 of 2