Loading...
HomeMy WebLinkAbout6/18/14 lightingspecs2014 Catalog Number Notes FEATURES & SPECIFICATIONS INTENDED USE — Provides a minimum of 90 minutes illumination for the rated w Type CONSTRUCTION - ® ® U.S. Patent No. D468,046. Die-Cast Architectural Emergency Light OPTICS AFN improve photometrics. Forward throw (FWD) option optics provided with two high-brightn projecting an NFPA-101 compliant path 3' wide and 28' forward, w life of the LED lamp is 10 years. All light sources meet requirements for NEC 700.16. Brushed Dual-voltage input capability (120/277V). Nickel Edge connectors on printed circuit board ensure long-term durabi Universal J-box mounting pattern. Easily visible green status indicator. Rigid conduit entry provision on top of the unit. Battery: Sealed, maintenance-free lead-calcium battery provides battery with Premium and Exterior option packages. Automatic 48-hour recharge after a 90-minute discharge. Low-voltage disconnect prevents excessively deep discharge that Single-circuit battery connection. ELECTRICAL — Current-limiting charger maximizes battery life and minimizes Provides low operating costs. Short-circuit protection — current-limiting charger circuitry pr Single multi-chromatic LED indicator to display two-state chargi Thermal protection senses circuitry temperature and adjusts chardiagnostic status. and charger failure. Test switch provides manual activation of 30-second diagnostic t Thermal compensation adjusts charger output to provide optimum c temperature. Diagnostic evaluation of lamp, AC to DC transfer, charging and b Regulated charge voltage maintains constant-charge voltage over AC functionality. over/undercharging that shortens battery life and reduces capaci Postpone automatic test initiates eight hour delay of an automat Filtered charger input minimizes charge voltage ripple and exten switch. AC/LVD reset allows battery connection before AC power is applie LISTINGS — UL Listed. Wet locations and cold temperature (EXT) listed. D deep discharge. Wet location (WL) option available with PREM package. Meets UL 9 Brownout protection is automatically switched to emergency mode illumination standards. UL labeled. 80 percent of nominal. WARRANTYWARRANTY — 3-year limited warranty. Complete warranty terms located at EXT option package includes 20-minute time delay for supplementawww.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Self-diagnostics (PREM and EXT option packages) Patented Electronics - U.S. Patent No. D468,046 and 6,502,044. Example AFN W EXT ORDERING INFORMATION bolded options. : AFN SeriesFinishOptions AFN AFFINITY Series die-cast architectural W White(blank)Features lead calcium battery emergency lighting C to 50°C) BBlackPREMFeatures ni-cad battery, self-diagnostics and damp location 32°F to 122°F (0° BNBrushed nickel EXT Features high-temperature ni-cad battery listed from 0°F to 122°F (-18°C to 50°C), self-diagnostics, time delay; listed for cold weather, damp and wet location DB Dark bronze FWDForward throw optics with LED light source, 10.8W 1 WLWet location listed from 32°F to 122°F (0°C to 50°C) 2 Accessories: Order as separate catalog number. ELA AFNR DB Notes equipment as part of an emergency lighting system (listed from - 1WL only available with PREM option package. 2See spec sheet ELA-OMC-ELA-AFNR . EMERGENCY AFN AFN MOUNTING SPECIFICATIONS All dimensions are inches (centimeters). ELECTRICAL: Primary Circuit Shipping weight: 3.5 lbs. (1.59 kgs.) AC InputOutputWatts output volts 2-3/44-3/84-3/8 Type VoltsAmpsWatts1-1/2 hrs. (6.9)(18.6)(18.6) 120.111.1 AFN612 277.121.3 120.151.4 AFN PREM612 277.141.4 1 120.2321 9-1/29-1/29-1/2 AFN EXT612 (24.1)(24.1)(24.1) 1 277.2535 BATTERY: Sealed Lead-Calcium 6-1/26-1/2 ShelfTypicalOptimum (16.5)(16.5) 2243 VoltagelifelifeMaintenancetemperature Test switch status 60°– 90°F 612 months 5 - 7 yearsnone indicator (16°– 32°C) FIXTURE PERFORMANCE Center-to-Center Spacing on a 3-foot BATTERY: Nickel-Cadmium Path of Egress ShelfTypicalOptimum 2243 VoltagelifelifeMaintenancetemperature 32°– 122°F 63 years7 - 9 yearsnone (0°– 50°C) 1 FC average Notes 1 EXT provided with battery heater. 0.1 FC min. 2 At 77°F (25°C). 3 Optimum ambient temperature range where unit will provide capaci for detailed information. 3 ft. 4 All life safety equipment, including emergency lighting for path tested in accordance with all National Fire Protection Associati Center-to-Center Spacing on a 6-foot the required maintenance, service, or testing could jeopardize t Path of Egress 21 ft. 1 FC average 0.1 FC min. 6 ft. ® AFFINITY FWD SPACING GUIDE XenonPath of EgressPath of Egress 1 FC average Lamp3'-wide 6'-wide 0.1 FC min. 8.5' Center-to-Center 26'21' Spacing 20' 3' 28' NOTE: Meets Life Safety Code standard minimum illuminance of 0.1 6' of 1.0 FC. Assumes open space with no obstructions, mounting hei AFN EMERGENCY: One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax: 770-981-8141 www.lithonia.com © 2003-2014 Acuity Brands Lighting, Inc. All rights reserved. Re RDIC Cat.#Approvals RADIUS Type Job COMPACT ARCHITECTURAL WALLPACK APPLICATIONS architecture. Complements larger Geometric wall sconce series – illumination and uniformity. Egress option available on CFL vers SPECIFICATIONS 6.25" (158 mm) 8.25"11.375" (209 mm)(288 mm) LISTINGS ORDERING INFORMATION – – – Series Wattage/Source/Voltage Finish Options SERIESWATTAGE/SOURCE/VOLTAGEFINISHOPTIONS 2,3 RDIC Radius Compact Pulse StartBZ Bronze BOC ® 70P8 70w PS Quad-Tap Wallpack PL Platinum 1 CFL 2,3® 42F8 42 CFL Quad-Tap 2 42F9 LED 13LU-5K Due to our continued efforts to improve our products, product sp T driver operates on any line voltage from voltage option. Single fuse (SF) requires 120, 277 options only when ordering with photocell 277 options only when ordering with photocell T driver operates on any line voltage from WST LED Catalog Number Architectural Wall Sconce Notes Type Hit the Tab key or mouse over the page to see all interactive el Introduction The classic Architectural Wall Sconce is now Inverted available with available with the latest in LED technology. The WLU option only. result is a long-life, maintenance-free product with typical energy savings of 75% compared to metal Luminaire Optional Back Box (BBW) halide versions. The integral battery backup option 7-1/4” 4” Height: Height: provides emergency egress lighting, without the (18.4 cm) (10.2 cm) use of a back-box or remote gear, so installations 16-1/4” 5-1/2” Width: Width: (41.3 cm) (14.0 cm) maintain their aesthetic integrity. 9-1/8” 1-1/2” Depth: Depth: The WST LED is ideal for replacing existing 50 – (23.2 cm) (3.8 cm) 175W metal halide wall-mounted products. The 17 lbs Weight: For 3/4” NPT D W (7.7 kg) 1-1/2 5-1/2 side-entry expected service life is 20+ years of nighttime use. conduit H H 4 D W Ordering Information WST LED 2 10A700/40K SR3 MVOLT DDBTXD EXAMPLE: WST LED Performance 3 Series Light EnginesDistributionVoltageMountingOptionsFinish Package 1 WSTLED One engine 700 mA options:SR2 Type II MVOLT Shipped includedShipped installed DDBXD Dark bronze 1 (10 LEDs) 4, 5 10A700/40K 4000K PE Photoelectric cell, button type DBLXD Black 1 SR3 Type III(blank)Surface mount 120 Two engines 4 2SF Single fuse (120, 277, 347V) DNAXD Natural aluminum 1 208 2 SR4 Type IV Shipped separately 4 (20 LEDs) DF Double fuse (208, 240, 480V) DWHXD White 1 240 BBW Surface-mounted DMG 0-10V dimming driver (no controls)DSSXD Sandstone back box 1 277 6 ELCW Emergency battery backup DDBTXD Textured dark bronze UT5 Uptilt 5 degrees 347 7 WLU Wet location door for up orientation DBLBXD Textured black 480 8 PIR Motion/ambient light sensor DNATXD Textured natural aluminum Shipped separately DWHGXD Textured white VG Vandal guard DSSTXD Textured sandstone WG Wire guard Emergency Battery Operation T driver operates on any line voltage from 1MVOLMVOL MVOL 120-277V (50/60 Hz). Specify 120, 208, 240 or 277 options only when ordering with photocell The emergency battery backup (ELCW option) is integral to the lu (PE option) or fusing (SF, DF options). emergency operation while maintaining the aesthetics of the prod 2May also be ordered separately as an accessory. May also be ordered separately as an accessory. 3Must be or engines are wired in parallel so both engines operate in emergen installed. features meet various interpretations of NFPA 70/NEC 2008 - 700.16 Not available with MVOL 4Not available with MVOLT option. Button Not available with MVOL The emergency battery will power the luminaire for a minimum dur photocell (PE) can be ordered with a dedicated supply power is lost, per International Building Code Section 1006 and NFPA 101 Life Safety Code Section 7.9, provided luminaires are voltage option. Single fuse (SF) requires 120, mounted at an appropriate height and illuminate an open space wi voltage option. Single fuse (SF) requires 120, 277 or 347 voltage option. Double fuse (DF) requires 208, 240 or 480 voltage option. The examples at right show illuminance Not available with 480V option. Not available 5 of 1 fc average and 0.1 fc minimum of with motion/ambient light sensor (PIR). the single-engine Type IV product in Integral battery pack is rated for -20° to 60°C 6 emergency mode. ELCW warranty is 3-year operating temperature. period. Not available with 347V or 480V. Not available with WLU. WLU not available with PIR or ELCW 7 . SensorSwitch SFD-7-ODP control 8 (photocell included); see Motion Sensor Guide for details. Not available with “PE” option (button type photocell). Dimming driver standard. Not available with WLU, VG or WG. One Lithonia Way  Conyers, Georgia 30012  Phone: 800.279.8www.lithonia.com © 2011-2013 Acuity Brands Lighting, Inc. All rights reserved. Performance Data 40K System Drive Dist. Light Performance (4000K, 70 CRI) Watts Current EnginesPackage Type Nominal (mA) 1 (MVOLT) BUGLPW Lumens SR2 2,00510184 10A700/--K24WSR3 700 2,02910184 (10 LEDs) SR4 1,959082 11 SR2 3,944084 11 2 70010A700/--K47WSR3 4,02810186 (20 LEDs) SR4 3,85110182 1See electrical load chart for 347/480V system watts. 0.240.140.120.1 -- 0.090.07 ---- 0.440.270.230.20 -- 0.170.12 ---- Higher wattage is due to electrical losses from step-down transformer. 1 Photometric Diagrams I Distribution overlay comparison to 175W metal halide. WST HID:WST LED: 213W47W SR2SR2SR2SR3SR3SR3SR4SR4SR4 WST LED 2 10A700 40K SR4, WST 175M FT Probe, 12’ Mounting Ht FEATURES & SPECIFICATIONS ELECTRICAL INTENDED USE The classic architectural shape of the WST LED was designed for integral aluminum heat sinks to maximize heat dissipation and pr schools, malls, restaurants, and commercial buildings. The long hrs at 25°C, L77). Class 2 electronic driver has a power factor luminaire nearly maintenance-free. serviceable surge protection device meets a minimum Category B ( CONSTRUCTION INSTALLATION The single-piece die-cast aluminum housing integrates secondary transfer from the internal light engine heat sinks and promote l down for easy access while making wiring connections. The integ direct contact with the casting for a low operating temperature mounting plate provides assistance for level placement on every frame is fully gasketed with a one-piece solid silicone gasket t providing an IP65 rating for the luminaire. LISTINGS FINISH rated and suitable for wet locations when mounted with the lense wet location listing in “up”orientation. Rated for -30°C minimum that provides superior resistance to corrosion and weathering. oduct. Not all versions of this product may changes without cracking or peeling. Standard Super Durable col www.designlights.org to OPTICS WARRANTY Precision-molded acrylic lenses are engineered for superior dist Five year limited warranty. Full warranty terms located at www.acuitybrands.com/ in wall-mount applications. Light engines are 4000K (70 CRI). CustomerResources/Terms_and_conditions.aspx . Globes™ criteria for eliminating wasteful uplight. Note: One Lithonia Way  Conyers, Georgia 30012  Phone: 800.279.8www.lithonia.com Rev. 12/09/13 © 2011-2013 Acuity Brands Lighting, Inc. All rights reserved.