HomeMy WebLinkAbout8/13/14 613 N. 1st Ave Retaining Engineering Memo 102513 CD IVILESIGN P ROFESSIONALS October 25, 2013 Joe Whitter Joe Whitters Landscaping, Inc. RE:The Piedmonte Retaining Wall (13 - 237) Iowa City, Iowa Design Assumptions: NCMA Safety Factors: Keystone Compac Units, Wall Batter Sliding 1.501.50 NCMA Design Overturning - Reinforced 2.00 Live Load:50 PSF Bearing 2.00 Dead Load:400 PSF Toe Slope:2.5H:1V Back Slope:2.5H:1V Seismic:N/A Soil Design Properties: c Reinforced Soil (Sandy Lean Clay) Reinforced Soil Retained Soil Retained Soil Foundation Soil Notes: Soils information obtained from Geotechnical Engineering Report prepared by Terracon Consultants, Inc. . dated July 12, 2013 Onsite material is predominately sandy lean clay. An internal friction angle of was assumed for the onsite material. Where unsuitable soils are found, a subcut may be required and structural fill shall be placed and compacted to provide an adequate bearing foundation. The above minimum soil strength parameters shall be verified prior to final design. CDP shall be contacted if the above soil strength parameters cannot be met and a redesign may be required. Wall layouts and elevations obtained from Site Grading Plans prepared by MMS Consultants last revised 09-13-13. Crushed Stone shall be required in the reinforced and retained zones of Walls 2, 3 and 5 in the stairway location and shall be constructed simultaneously with the stairw During wall construction, excavation shall remain within the construction limits shown on the plans. All available means and methods used to keep excavation within the construction limits shall be incidental. The contractor shall coordinate relocation of all existing conduits We appreciate the opportunity of providing services to you. If you have any questions or comments regarding this project, please feel free to contact us. Steve Schilling Civil Design Professionals 8609 Lyndale Ave. S., Suite 200 Bloomington, MN 55420 Civil Design Professionals Office (952) 303-5312 www.cdp-us.com Joe Whitters Landscaping, Inc. The Piedmonte Project # 13 - 237 The final quantities are as follows: Wall Length4" Cap Area8" Cap AreaGrid Length Block AreaSG200 Wall (FT)(SF)(SF)(SY)(SY)(FT) 2,1501,003 335.251505-11 1N/A 269.001601556665-8 372.0036515531795-9 486.2529540N/A896 540.50851035325-6 627.0030010N/A18912 3,3551,558 Totals: 630.00240N/A 144 The unit area and volume quantities are neat quantities. Contractor shall confirm the quantities and add in any additional necessary factors (i.e., waste, compaction, etc.) The grid quantity includes a 5% waste factor. The total wall area of the walls is 3,739 SF (3,355 SF Blocks + 8609 Lyndale Ave. S., Suite 200 Bloomington, MN 55420 8609 Lyndale Ave. S., Suite 200 Bloomington, MN 55420 Civil Design Professionals Civil Design Professionals Office (952) 303-5312 Office (952) 303-5312 www.cdp-us.com www.cdp-us.com