Loading...
HomeMy WebLinkAbout9/22/14 plans2014 Building Details for 227 Magowan 1.Foundation a.Slab on grade floor, 4 thick with 2 rigid foam insulation underneath typical, footings to below frost see engineering for additional footing details b.Concrete walls 10 thick typical x approximately 12 tall, see engineering plans for additional details i.Closed cell sprayed foam in 2 x 4 framed wall to the interior R21 ii. sheetrock covering framed walls iii.Note: deadmen were able to be eliminated with additional steel and t a precast floor to create structural diaphragm c.Walkout walls 2 x 6 walls typical i. drywall inside ii.2 x 6 walls 16 o.c. iii.R21 closed cell foam insulation iv. osb sheathing v.1 rigid foam continuous insulation vi.Tyvek drainage plane vii.Fiber cement lap siding to the exterior painted d.Floor Assemblies i.Garage floor precast concrete see engineering for additional detail drawings ii.2-3 iii.Closed cell foam sprayed to bottom side iv.Underside is also framed and drywalled with 5/8 drywall to create chase space for ductwork and can lights e.Framed floor assembly under the mudroom i.Tile floor ii.T & G subfloor iii.2 x 12 floor framing iv.5/8 drywall below f.Upper level walls i. drywall to the interior ii.R21 Closed cell foam insulation iii.2 x 6 wall framing iv. osb sheathing v.1 rigid foam continuous insulation vi.Tyvek vii.Fiber cement lap siding to the exterior painted g.Roof Assembly i.Asphalt shingles ii.Ice/water shield iii. plywood sheathing iv.Manufactured trusses with energy heels v.R40 open cell foam insulation sprayed to lid vi.5/8 drywall to the interior vii.Aluminum Soffit viii.Aluminum Fascia ix.Aluminum 5 gutters match existing house