Loading...
HomeMy WebLinkAbout9/26/14 ENERGY LETTER 3076 Lower West Branch Rd Lot 2 Rochester Ridge RES check Software Version 4.3.1 Compliance Certificate Project Title: LOT 2 ROCHESTER RIDGE, 3076 Lower West Branch Rd 2009 IECC Energy Code: Iowa City, Iowa Location: Single Family Construction Type: Bldg. faces 180 deg. from North Building Orientation: 12% Glazing Area Percentage: 6227 Heating Degree Days: 5 Climate Zone: Construction Site:Owner/Agent:Designer/Contractor: 3076 Lower West Branch RdJesse AllenMichael Untrauer Iow City, IAAllen HomesUntrauer Drafting Service, Inc. Permit Date: Sept 2014530-82382260 Shropshire Coralville, IA 52241 319 430-0760 untrauer@gmail.com Passes using UA trade-off Compliance: 0.0% Better Than Code452452 Compliance: Maximum UA: Your UA: The % Better or Worse Than Code index reflects how close to comp It DOES NOT provide an estimate of energy use or cost relative t GrossCavityCont.GlazingUA AssemblyArea orR-ValueR-Valueor Door PerimeterU-Factor Basement Wall 4: Solid Concrete or Masonry40013.00.026 Orientation: Back Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Window 4: Vinyl Frame:Double Pane with Low-E600.30018 SHGC: 0.22 Orientation: Left Side Ceiling: Flat Ceiling or Scissor Truss166538.00.050 Exterior Wall 1: Wood Frame, 16" o.c.87819.00.042 Orientation: Front Window 1: Vinyl Frame:Double Pane with Low-E1350.30041 SHGC: 0.22 Orientation: Front Door 1: Solid400.1506 Orientation: Front Wall 2: Wood Frame, 16" o.c.87819.00.042 Orientation: Back Window 2: Vinyl Frame:Double Pane with Low-E1720.30052 SHGC: 0.22 Orientation: Back Wall 3: Wood Frame, 16" o.c.70319.00.039 Orientation: Left Side Wall 4: Wood Frame, 16" o.c.70319.00.041 Orientation: Right Side Window 3: Vinyl Frame:Double Pane with Low-E120.3004 SHGC: 0.22 Orientation: Right Side Basement Wall 1: Solid Concrete or Masonry40013.00.022 Orientation: Front Wall height: 8.0' Depth below grade: 7.5' Project Title: LOT 2 ROCHESTER RIDGE, 3076 Lower West Branch RdReport date: 09/19/14 Data filename: C:\Users\Mike\Documents\drawings\REScheck\Jesse Allen lot 12 RocPage 1 of 2 Insulation depth: 8.0' Basement Wall 2: Solid Concrete or Masonry29613.00.022 Orientation: Left Side Wall height: 8.0' Depth below grade: 4.0' Insulation depth: 8.0' Basement Wall 3: Solid Concrete or Masonry29613.00.022 Orientation: Right Side Wall height: 8.0' Depth below grade: 4.0' Insulation depth: 8.0' Floor 1: All-Wood Joist/Truss:Over Unconditioned Space53119.00.025 Compliance Statement: The proposed building design described here is consistent with calculations submitted with the permit application. The proposed RES check Version 4.3.1 and to comply with the mandatory requirements lis check Inspection Checklist. Name - TitleSignatureDate Project Title: LOT 2 ROCHESTER RIDGE, 3076 Lower West Branch RdReport date: 09/19/14 Data filename: C:\Users\Mike\Documents\drawings\REScheck\Jesse Allen lot 12 RocPage 2 of 2