HomeMy WebLinkAbout9/26/14 ENERGY LETTER 3076 Lower West Branch Rd Lot 2 Rochester Ridge
RES check Software Version 4.3.1
Compliance Certificate
Project Title: LOT 2 ROCHESTER RIDGE, 3076 Lower West Branch Rd
2009 IECC
Energy Code:
Iowa City, Iowa
Location:
Single Family
Construction Type:
Bldg. faces 180 deg. from North
Building Orientation:
12%
Glazing Area Percentage:
6227
Heating Degree Days:
5
Climate Zone:
Construction Site:Owner/Agent:Designer/Contractor:
3076 Lower West Branch RdJesse AllenMichael Untrauer
Iow City, IAAllen HomesUntrauer Drafting Service, Inc.
Permit Date: Sept 2014530-82382260 Shropshire
Coralville, IA 52241
319 430-0760
untrauer@gmail.com
Passes using UA trade-off
Compliance:
0.0% Better Than Code452452
Compliance: Maximum UA: Your UA:
The % Better or Worse Than Code index reflects how close to comp
It DOES NOT provide an estimate of energy use or cost relative t
GrossCavityCont.GlazingUA
AssemblyArea orR-ValueR-Valueor Door
PerimeterU-Factor
Basement Wall 4: Solid Concrete or Masonry40013.00.026
Orientation: Back
Wall height: 8.0'
Depth below grade: 6.0'
Insulation depth: 8.0'
Window 4: Vinyl Frame:Double Pane with Low-E600.30018
SHGC: 0.22
Orientation: Left Side
Ceiling: Flat Ceiling or Scissor Truss166538.00.050
Exterior Wall 1: Wood Frame, 16" o.c.87819.00.042
Orientation: Front
Window 1: Vinyl Frame:Double Pane with Low-E1350.30041
SHGC: 0.22
Orientation: Front
Door 1: Solid400.1506
Orientation: Front
Wall 2: Wood Frame, 16" o.c.87819.00.042
Orientation: Back
Window 2: Vinyl Frame:Double Pane with Low-E1720.30052
SHGC: 0.22
Orientation: Back
Wall 3: Wood Frame, 16" o.c.70319.00.039
Orientation: Left Side
Wall 4: Wood Frame, 16" o.c.70319.00.041
Orientation: Right Side
Window 3: Vinyl Frame:Double Pane with Low-E120.3004
SHGC: 0.22
Orientation: Right Side
Basement Wall 1: Solid Concrete or Masonry40013.00.022
Orientation: Front
Wall height: 8.0'
Depth below grade: 7.5'
Project Title: LOT 2 ROCHESTER RIDGE, 3076 Lower West Branch RdReport date: 09/19/14
Data filename: C:\Users\Mike\Documents\drawings\REScheck\Jesse Allen lot 12 RocPage 1 of 2
Insulation depth: 8.0'
Basement Wall 2: Solid Concrete or Masonry29613.00.022
Orientation: Left Side
Wall height: 8.0'
Depth below grade: 4.0'
Insulation depth: 8.0'
Basement Wall 3: Solid Concrete or Masonry29613.00.022
Orientation: Right Side
Wall height: 8.0'
Depth below grade: 4.0'
Insulation depth: 8.0'
Floor 1: All-Wood Joist/Truss:Over Unconditioned Space53119.00.025
Compliance Statement: The proposed building design described here is consistent with
calculations submitted with the permit application. The proposed
RES check Version 4.3.1 and to comply with the mandatory requirements lis check Inspection Checklist.
Name - TitleSignatureDate
Project Title: LOT 2 ROCHESTER RIDGE, 3076 Lower West Branch RdReport date: 09/19/14
Data filename: C:\Users\Mike\Documents\drawings\REScheck\Jesse Allen lot 12 RocPage 2 of 2