HomeMy WebLinkAbout11/3/14 wendyspecs2014 Wendy's Remodel 1480 South 1st Avenue Iowa City, IA 52240 2009 International Building Code 2009 Uniform Plumbing Code Start of 2009 International Building Code Chapter 3 - Use and Occupancy Classifications A-22,694sq.ft. Total2,694 sq.ft. Chapter 5 - General Building Heights and Areas Type V-B Table 503 A-2 = 6,000 allowable square feet Section 506 - Allowable Area Increases A = A + [A I/100] + [A I/100] attfts If = 100[F/P – 0.25]W/30 F = 248' P = 248' W = 30’ If = 75 Is = 0 No areas will be fully sprinkled in acoordance with Section 903.3.1.1. A = 2,694 + [2,694* 75/100] a A = 4,715 allowable square feet a Chapter 6 - Types of Construction Table 601 - Type V-B Building ElementFire-Rating Structural Frame0 Bearing Walls Ext.2 Int.0 Nonbearing Ext. WallsTable 602 Nonbearing Int. Walls0 Floor Construction0 Roof Construction0 Table 602 - B Occupancy Fire Separtion DistanceFire-Rating x < 30'0 Chapter 9 Fire Protection Systems Section 903 Automatic Sprinkler Sytems No fire automatic fire sprinkler system is required as none of the condiitons area met (1-3). Section 906 Portable Fire Extinguishers One (1) portable fire extinguisher shall be provided in each Dining Area and Commercial Kitchen. Section 907 Fire Alarm and Detection Systems 907.2.1 Group A Fire alarm and detection system is NOT required in A occupancy groups with less than 300 occupants. Chapter 10 - Means of Egress Section 1004 Occupant Load - Table 1004.1.2 Floor area per sq.ft. per Occupancy occupantOccupant LoadArea SF Dining/Waiting area83persons Comm. Kitchen200gross813sq.ft.4persons Other Employees10persons 97persons Total building occupant load Section 1005 Egress Width - Table 1005.1 97 persons x 0.2 = 20" required egress width Dining Area 66" provided at (2) two exits 66"iddt(2)tit Commercial Kitchen 33" provided at (1) one exit Section 1014.3 Common Path of Egress Travel Longest Common path of egress travel is 30'-0", not exceeding max 75'-0". Section 1016 Exit Acess Travel Distance - Table 1016.1 Max. allowableLongest traveltravel distancedistance A-220083'-4" Chapter 29 - Plumbing Systems Table 2902.1 Minumum Number of Required Plumbing Fixtures A-297 occupants MaleFemale ToiletsLavatoriesToiletsLavatories 1:751:2001:751:200 Occupants48484949 Req'd Fixture Count 0.640.240.650.25 Provided fixtures MaleFemale ToiletsLavatoriesToiletsvatories a 1111 - (1) Service sink to be provided End of 2009 International Building Code