HomeMy WebLinkAbout12/1/14 plansasbuiltdesignset2014
FAMILY & GRADUATE HOUSING
Issued for Permit & Construction
A0.10
Sheet Number:
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
Dallas, TX 75201
Project Number:
2012042
Checked By:
06.07.201305.03.2013
10th Floor
Drawn By:
DATE
MS / JP
NO.
Index of Drawings
1
New Site Spot Elevation
New Curb/Gutter Elev.
Revision Bubble & Tag
Floor Finish Transition
"A"
Elevator/Stair Target
Change in Elevation
Equipment NumberGutter Datum Elev.
Elevation NumberElevation NumberPoint of BeginningCurb Datum Elev.
Interior Elevations
Exterior Elevation
Keynote NumberSite Datum Elev.
for Dimensioning
Circulation Type
Equipment Tag
Sheet NumberSheet Number
Height of Step
Keynote Tag
Match Line
Workpoint
Number
3
Architectural Symbols
2B
A7.1
A6STAIR2
12
3
NO.
4
"A"
Section NumberSection Number
Building Section
Sheet NumberSheet NumberSheet Number
Detail Number
Detail Section
Wall Section
Detail Reference Bubble
Exist. Curb/Gutter Elev.
Building Spot Elevation
Building Datum Elev.Building Datum Elev.
Column Grid & Bubbles
Gutter Datum Elev.
Curb Datum Elev.
Room Reference
Ceiling Elevation
Sheet NumberRoom NumberFloor Elevation
Detail Number
Door Number
Partition Type
Window Type
Partition Tag
Room NameWindow Tag
Floor Name
Door Tag
A3.3A4.1A4.1
322
CEILING HT.
10'-0" A.F.F.
CONFERENCE
A9.1
FIRST FLOOR
5
2 HR
ROOMROOM
+0'-0"
MAIN
54
101101
201
EL:
A3.3
3
Particle Board-Large Scale
Particle Board-Small Scale
Metal Lath and Plaster
Gypsum Wallboard
Steel/Other Metals
Plaster/Cut Stone
Concrete Block
Sand/Mortar/
Granular Fill
Spray/Foam
Terrazzo
Rough
Material Designations
Plywood-Large ScalePlywood-Small Scale
Common/Face Brick
Glass - Large Scale
Earth/Compact Fill
Resilent Flooring/
Plastic Laminate
Carpet and Pad
Batt/Loose Fill
Cast-in-Place
Ceramic Tile
Aluminum
Precast
Project Data
Finish
Rigid
Insulation/Fireproofing
Large Scale Finishes
Earthworks
Concrete
Masonry
Metal
WoodGlass
Vinyl Composition Tile
Welded Wire Fabric
Tongue & Groove
Water Repellent
Revision(s),(ed)
Rough OpeningSpecification(s)
Stainless SteelSymmetry(ical)
Textured Paint
Working Point
Waterproofing
Vapor Barrier
Water Closet
Right of Way
RefrigeratorWall to Wall
Storm Drain
Width, Wide
Vinyl Fabric
Right Hand
Quarry Tile
Roof Drain
Return AirSolid CoreTelephoneTowel BarUnfinished
ReferenceStructuralTemperedVinyl Base
TelevisionWall Hung
Undercut
Wainscot
Schedule
Standard
Rail(ing)RegisterTerrazzo
VerticalWithout
RoofingStorageTypical
SectionShingle
SimilarSquareWindow
RadiusTop of
System
RiserSouthSteelTread
ThickWestWood
RoomVinyl
WSCT
SHNG
REFRSECTSPECSTORVERT
WWF
SIMR
WTWWPT
ROWUNF
RADREFREGREVRFGSCHSSTSYMSYSTHKVCT
STDSTLSTRTELT>YPWIN
VINWHWCWPWRWOWD
QT
RLRARHRDRMROSCSQSDUCVBVBVF
TVTZTPT/TB
RSTTWWW
Portland Cement Concrete
Pounds per Square Foot
Pounds per Square Inch
Pounds per Lineal Foot
Pounds per Cubic Foot
Non Freezing Sill Cock
General Contract(or)Lightweight Concrete
Heating/Ventilating/
Outside Diameter
Hot Water HeaterMasonry OpeningPolyvinyl Chloride
Opposite SurfacePrecast Concrete
Gypsum DrywallModular, Module
Plastic Laminate
Inside DiameterInsulate(d),(ion)
Mount(ed),(ing)
Air ConditioningNot in Contract
Include(d),(ing)Manufacture(r)Prefabricate(d)
Janitor's closetOpposite Hand
Glass, GlazingMiscellaneous
Particle Board
Machine BoltOn Center(s)
Gage, GaugeHollow MetalMechanic(al)Property Line
Millimeter(s)
Perforate(d)
Laminate(d)Not to Scale
Hollow Core
Heavy Duty
Prefinished
Galvanized
High PointMembranePavement
HorizontalPreformed
HardboardLow PointPerimeter
Limestone
KnockoutOverhead
HardwareLeft HandLive LoadPaint(ed)
Grab Bar
MaximumNominalOpposite
Hose BibMasonry
LavatoryManholeMinimumOpeningPlywood
Partition
SITE Natural
Overall
HeaderHeatingPlaster
InteriorKitchen
GraniteGravelLouverMullion
D HeightMarble
LengthPanel
Metal
GroutInvertLabel
R LintelPoint
North
Light
HourJointPlate
A
V
E
L
U
O
B
K
E
PVMNT
R
MEMB
T MECH
GPDWMULL
GALVHVACNFSCPERFPERI
PLASPLAM
MISC
N HWHINCL
MRBMODPWD
GRNGVLHDWHDRHORLWCMFRMASMAXMTLNOMOPGOPPOPHOPS
HBDHTGLMSNATNTSPNTPNLPBDPVCPCCPCFPSFPSIPCCPRF
O LBLLAMLAVLVRPTNPLFPFBPFN
LTLMIN
INSINTINVNIC
KIT
GAGCGLGBGTMBMHMOMMMTOCODOAOH
M HDHTHPHCHMHRHBKOPLPTPL
LHLTLLLP
JCJT
R ID
LN
O
M
Abbreviations
Location Map
Fire Extinguisher Cabinet
Flathead Machine Screw
Concrete Masonry UnitContinuous or Continue
Cast in Place Concrete
Above Finished FloorElectric Water CoolerFlathead Wood Screw
D Electrical Panelboard
A Ceramic Mosaic Tile
Anchor, Anchorage
O
R
Drinking FountainFasten, Fastener
Face of ConcreteFire ExtinguisherFire Hose Station
K Face of Masonry
Expansion Joint
Built Up Roofing
Cement Plaster
R Air Conditioning
Expansion Bolt
A
Access PanelCompartment
P Centimeter(s)Face of FinishFace of StudsFactory Finish
Control Joint
Double Hung
E
Ceramic TileCombinationCompositionConstructionContract(or)
Anchor BoltClear(ance)
Bench MarkCatch Basin
Y Downspout
Cubic FootEmergency
BituminousFoundation
E AcousticalCubic YardDead LoadElectric(al)Floor Drain
Area DrainCasementEach FaceFace Brick
DimensionFiberglassFinish(ed)
AddendumBottom ofCourse(s)
K AutomaticFloor(ing)
DiagonalDiameterDrain Tile
AdjacentAluminumElevation
AlternateCast IronConcrete
W ElevatorExhaustExposed
BlockingCementDamperFlashing
DrawingExterior
AsphaltBuilding
A BearingColumnCopperDivisionDrawerExistingFlexible
Footing
Carpet
H Ceiling
BottomDetailEqual
Above
TRU BoardDoor
OC E Below
YEKW Flush
AH Drain
BrickEast
Ditto
COMPTCOMPO
CONST
CONTR
COMB
CSMTCONCCONTFHWS
EMERFHMS
ASPHAUTO
BLKGBLDGELEV
EXJT
CIPCDIAGDIAMDWRDWG
CMTCMUEWC
BOTCOLCRS
ABVADDADJANCBRGBELBRKBURCPTCEMCPRCFTCYDDPRDTLEXHEXGEXPEXTFOCFOFFOMFOSFGLFHSFND
AFFALTCLGCLRCJTFASFECFTG
FLGFLXFLR
DIMDIV
A/CBITFIN
APACALABADBMBDB/CICBCPCMCTDLDODRDHDSDTDFEFELEPELEQEB
FBFFFEFDFL
DE
A0.20
Unit Interior Finish Schedule
Interior Finish Schedule
Exterior Finish Schedule
A0.25
GENERAL NOTES
A0.30A
A0.30B
MINIMUM NO. OF REQUIRED EXITS
OCCUPANTS ALLOWEDOCCUPANTS ALLOWED
GROSS OR NET AREA (SQ. FT.)
OCCUPANCY CLASSIFICATION
OCCUPANCY LOAD FACTOR
A0.31
OCCUPANCY CONTENT
STAIR NO.
'B' LABEL DOOR - 1 1/2 HR RATED
ROOM NAME
'C' LABEL DOOR - 3/4 HR RATED
FINAL DISCHARGE TO PUBLIC WAY
'A' LABEL DOOR - 3 HR RATED
20 MINUTE - 1/3 HR RATED
GENERAL NOTES
60 MINUTE - 1 HR RATEDFIRE DEPARTMENT ACCESSFIRE ALARM ANNUNCIATOR
TRAVEL DISTANCE (T.D.)
EXIT DOOR
LEGEND
X FT.
A444A444
A444A444
UPUP
DN
A444
A444
A444A444A444A444
A4444444444444A4444444444444
A4444444444444
A4444444444444
A444A444A444A444
A444A444A444A444
A444A444A444A444
A444
A444444444444
A444
A444A444
A444A444
A444A444
A444A444
A444A444
A444A444
A444A444
A4444444444444A4444444444444
A4444444444444A4444444444444
A444A444A444A444
A444
A444
A444A444
A444
A444
DN
A444 UP A444 UP
A444A444
A444A444A444
A44444A44444A44444
A44444A44444A44444
A444A444A444
MINIMUM NO. OF REQUIRED EXITS
OCCUPANTS ALLOWEDOCCUPANTS ALLOWED
GROSS OR NET AREA (SQ. FT.)
OCCUPANCY CLASSIFICATION
OCCUPANCY LOAD FACTOR
A0.32
OCCUPANCY CONTENT
STAIR NO.
'B' LABEL DOOR - 1 1/2 HR RATED
ROOM NAME
'C' LABEL DOOR - 3/4 HR RATED
FINAL DISCHARGE TO PUBLIC WAY
'A' LABEL DOOR - 3 HR RATED
20 MINUTE - 1/3 HR RATED
GENERAL NOTES
60 MINUTE - 1 HR RATEDFIRE DEPARTMENT ACCESSFIRE ALARM ANNUNCIATOR
TRAVEL DISTANCE (T.D.)
EXIT DOOR
LEGEND
X FT.
A444
A444
A444
A44444
A44444A44444
A44444A44444
A444
A444
UP
A444
A444
A444
A444
A444
A444A444
A444A444
A444A444
A4444444444444
A444A444
A444A444
A4444444444444
A444A444
A444
A444
A444
A444 UP
A444
OCCUPANTS ALLOWEDOCCUPANTS ALLOWEDMINIMUM NO. OF REQUIRED EXITS
GROSS OR NET AREA (SQ. FT.)
OCCUPANCY CLASSIFICATION
OCCUPANCY LOAD FACTOR
A0.33
OCCUPANCY CONTENT
STAIR NO.
'B' LABEL DOOR - 1 1/2 HR RATED
ROOM NAME
'C' LABEL DOOR - 3/4 HR RATED
FINAL DISCHARGE TO PUBLIC WAY
'A' LABEL DOOR - 3 HR RATED
20 MINUTE - 1/3 HR RATED
GENERAL NOTES
60 MINUTE - 1 HR RATEDFIRE DEPARTMENT ACCESS
FIRE ALARM ANNUNCIATOR
TRAVEL DISTANCE (T.D.)
EXIT DOOR
LEGEND
X FT.
A444
A444
A444
A44444A44444A44444
A44444
A444
A444
UP
DN
A444
A444
A444
A444
A444
A444
A444A444
A444A444
A444A444
A4444444444444
A444A444
A444A444
A4444444444444
A444A444
A444
A444
A444
DN
A444 UP
A444
A0.34
UP
DN
UP
DN
DN
DNUP
..
MINIMUM NO. OF REQUIRED EXITS
OCCUPANTS ALLOWEDOCCUPANTS ALLOWED
GROSS OR NET AREA (SQ. FT.)
OCCUPANCY CLASSIFICATION
OCCUPANCY LOAD FACTOR
A0.35
OCCUPANCY CONTENT
STAIR NO.
'B' LABEL DOOR - 1 1/2 HR RATED
ROOM NAME
'C' LABEL DOOR - 3/4 HR RATED
FINAL DISCHARGE TO PUBLIC WAY
'A' LABEL DOOR - 3 HR RATED
20 MINUTE - 1/3 HR RATED
GENERAL NOTES
60 MINUTE - 1 HR RATEDFIRE DEPARTMENT ACCESSFIRE ALARM ANNUNCIATOR
TRAVEL DISTANCE (T.D.)
EXIT DOOR
LEGEND
X FT.
A444
A
4
4
4
A444
A444
A444
A444444444444
A444
A444
A444
A444
A444
A444
A44
4
UNIT FEATURE
ACCESSIBLE (MOBILITY FEATURE) UNIT
UNIT FLOOR & NUMBER
COMPLY WITH STANDARDS OF REACH RANGE
COMPLIANCE INFORMATION FOR TYPE B AND
OUTLETS, SWITCHES AND CONTROLS ABOVE A0.40
HABITABLE ROOMS INCLUDING BATHROOMS.
PROVIDE LEVER HARDWARE ON ALL DOORS.
SEE SHEETS A6.40 SERIES FOR ACCESSIBLE
SEE SHEETS A6.30 SERIES FOR ADAPTABLE
VISUAL ALARM DEVICES AND WIRES IN ALLLAVATORY, SINK & SHOWER CONTROLS IN Issued for Permit & Construction
PROVIDE CONDUIT, JUNCTION BOXES AND
PROVIDE LEVER TYPE HARDWARE AT ALL COMMUNICATION FEATURE UNIT
PROVIDE REINFORCING AT ALL TOILETS,COVERS FOR FUTURE INSTALLATION OFTHE COUNTERS AND ELSEWHERE MUST
SEE SHEETS A6.30 & A6.40 SERIES FOR
BATHTUBS AT INITIAL CONSTRUCTION.
SEE SHEET A0.41 FOR ACCESSIBILITY
UNIT TYPE
Issued for Code Review
University of Iowa
GENERAL NOTES
DIMENSIONED UNIT PLANS.
GENERAL NOTES AT ALL UNITS:
ACCESSIBLE UNIT PLANS DESCRIPTION
ALL BATHS/KITCHENS.
2013 Solomon Cordwell Buenz
ASI-007
LEGEND
10.21.201306.07.201305.03.2013
UNITS.UNITS.
DATE
4.
1.2.3.5.6.7.8.9.NO.
1
SEE SHEETSEE SHEET
A6.42A6.42
SEE SHEET
BUILDING B2 - ACCESSIBLE UNITSBUILDING B1 - ACCESSIBLE UNITS
BUILDING A3 - ACCESSIBLE UNITS
BUILDING A2 - ACCESSIBLE UNITSBUILDING A1 - ACCESSIBLE UNITS
SEE SHEET
A6.42
SEE SHEET
A6.42
SEE SHEET
A6.42
(ROLL-IN SHOWER)
A6.41
SEE SHEET
A6.40
(ROLL-IN SHOWER)
SEE SHEET
SEE SHEET
SEE SHEET
A6.42
A6.40
A6.40
SEE SHEET
1"=40'-0"1"=40'-0"
1"=40'-0"
1"=40'-0"1"=40'-0"
SEE SHEET
A6.42
A6.40
SEE SHEET
SCALE:SCALE:
SCALE:
SCALE:SCALE:
SEE SHEET
A6.41
A6.41
(UNLESS OTHERWISE NOTED)(UNLESS OTHERWISE NOTED)(UNLESS OTHERWISE NOTED)
DIMENSIONS TO FINISHED FLOORDIMENSIONS TO FINISHED FLOORDIMENSIONS TO FINISHED FLOOR
BATH GRAB BAR BLOCKING
PLAN TYPE "A" / FULLY
ACCESSIBLE UNITS
MEDICINE CABINET AND MIRROR
(UNLESS NOTED OTHERWISE)(UNLESS NOTED OTHERWISE)
TYPICAL MOUNTING HEIGHTS
REINFORCING FOR
GRAB BARS, TYP.
SHOWER SEAT
SWING DOWN
GRAB BARS
TYPICAL MEDICINE
CABINET
WALL MOUNT DUAL DRINKING FOUNTAIN
MINIMUM GRAB BAR BLOCKING
REQUIRED FOR 24" GRAB BAR
MINIMUM REINFORCED AREA -
2" EACH SIDE OF CENTERLINE
HOLDER LOCATION
MOUNTING HEIGHT
TOILET PAPER
DISTANCE FROM LIP OF
W.C. TO CENTER OF
MOUNTING PLATE
1 1/2" GRAB BAR
TOILET PAPER
OF BAR
TYPICAL TOWEL RING
TYPICAL TOWEL BAR
TOWEL BAR WHEN
LOCATED ABOVE
AND SHELF MOUNTING HEIGHT
FIRE EXTINQUISHER
TOWEL BAR, TOWEL RING
LOCATIONLOCATION
WATER CLOSET
TOILET
ACCESSIBLE
DISTANCE FROM LIP OF
CABINET
W.C. TO CENTER OF
TOILET PAPER
WALL CABINET
3. IF GRAB BARS ARE MOUNTED ADJACENT TO WALL, THE SPACE BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1-1/2 INCHES.
CLOSE PROXIMITY TO EACH OTHER ON1. GENERAL CONTRACTOR TO PROVIDE REINFORCEMENT FOR THE FUTURE INSTALLATION OF GRAB BARS AT ALL TOILETS.
UNLESS NOTED OTHERWISE, WHEREOUTLETS @ UNIT KITCHEN
SEVERAL DEVICES ARE MOUNTED INWATER SUPPLY
ELECTRICAL AND PHONE
THE WALL, COORDINATE WITH ALL
ELECTRICAL OUTLET
TRADES TO ALIGN DEVICES.
STROBE ALARM
COUNTERTOPS
LIGHT SWITCH
TO 1-1/2 INCHES (32 MM. TO 38 MM.), OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE.
4. LOAD REQUIREMENT FOR GRAB BARS TO MEET 250 POUNDS OF VERTICAL AND HORIZONTAL FORCE.
2. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF GRAB BAR SHALL BE 1-1/4 INCHES
UNIT BATHROOM DOOR
BATH FAUCET LOCATION
PLAN TYPE "A" / FULLY
CL
ACCESSIBLE UNITS
ACCESSIBLE TOILET GRAB BAR BLOCKING
DIMENSIONS ARE TO FINISHED FLOOR
ELECTRICAL DEVICES
ROBE HOOK AT PLAN TYPE
ADDITIONAL ACCESSIBLEADDITIONAL ACCESSIBLE
"A" AND ACCESS. UNITS
DOOR VIEWER AT PLANDOOR LEVER
SHOWER SLIDE
DOOR VIEWER AT ALLW/ HAND HELD
CURTAIN RODSHOWER ANDMIN. 60" HOSE
TYPE "A" AND FULLY
ROBE HOOK AT ALL
ACCESSIBLE UNITSCENTER ON
CONTROLS
OFFSET
DRAIN
5. FLUSH LEVER TO BE ON WIDE SIDE OF STALL, TYP.
UNITSUNITS
ALL BLOCKING TO BE 186A. SHT. METAL.
BATH FAUCET LOCATION
CIRCUIT BREAKER PANEL
TYPICAL UNITS
ELECTRICAL OUTLET @
PHONE/DATA OUTLETUNIT ENTRY DOOR
UNIT BATHROOMS &
LAUNDRY CLOSETS
LIFE SAFETY HORN
THERMOSTATS
Accessibility / Adaptability Features
COVERS FOR FUTURE INSTALLATION OF VISUAL
LAVATORY, SINK & SHOWER CONTROLS IN ALL
ALARM DEVICES AND WIRES IN ALL HABITABLE
PROVIDE LEVER HARDWARE ON ALL DOORS.
FURNITURE SHOWN FOR REFERENCE ONLY.
SEE SHEETS A6.40 SERIES FOR ACCESSIBLE
SEE SHEETS A6.30 SERIES FOR ADAPTABLE
PROVIDE LEVER TYPE HARDWARE AT ALL
PROVIDE CONDUIT, JUNCTION BOXES AND
PROVIDE REINFORCING AT ALL TOILETS,
BATHTUBS AT INITIAL CONSTRUCTION.
SEE SHEETS A6.30 & A6.40 SERIES FOR
A0.41
Issued for Permit & Construction
ACCESSIBLE DOOR
ROOMS INCLUDING BATHROOMS.
PUSH FORWARDWITH PARALLEL
APPROACH
DIMENSIONED UNIT PLANS.
Issued for Code Review
University of Iowa
BATHS/KITCHENS.
DESCRIPTION
2013 Solomon Cordwell Buenz
ASI-007
UNITS.UNITS.
ACCESSIBLE DOORPUSH FORWARD ATACCESSIBLE DOORPUSH FORWARD AT
UNIT INTERIOR
UNIT ENTRY
10.21.201306.07.201305.03.2013
1.2.3.4.5.6.7.8.
DATE
NO.
1
REMOVABLE BASECABINET -FIRST FLOOR ONLYREMOVABLE BASECABINET -FIRST FLOOR ONLYNO BASE CABINET -FIRST FLOOR ONLY
2 BED / 2 BATH - TYPE 'B' UNIT PLAN2 BED / 1 BATH - TYPE 'B' UNIT PLAN1 BED / 1 BATH - TYPE 'B' UNIT PLAN
CABINET -FIRST FLOOR ONLY
REMOVABLE BASE
1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"
SCALE:SCALE:SCALE:
ACCESSIBLE ROUTEACCESSIBLE ROUTEACCESSIBLE ROUTE
FIRST FLOOR ONLY
REMOVABLE BASE
HATCH INDICATESHATCH INDICATESHATCH INDICATES
CABINET -
2 BED / 1 BATH - ACCESSIBLE UNIT PLAN1 BED / 1 BATH - ACCESSIBLE UNIT PLAN
2 BED / 2BATH - ACCESSIBLE UNIT PLAN
1/4" = 1'-0"1/4" = 1'-0"1/4" = 1'-0"
SCALE:SCALE:SCALE:
ACCESSIBLE ROUTE
HATCH INDICATES
ACCESSIBLE ROUTEACCESSIBLE ROUTE
HATCH INDICATESHATCH INDICATES
1 BED / 1 BATH - ACCESSIBLE UNIT PLAN (ROLL-IN SHOWER)
2 BED / 2BATH - ACCESSIBLE UNIT PLAN (ROLL-IN SHOWER)
1/4" = 1'-0"1/4" = 1'-0"
SCALE:SCALE:
ACCESSIBLE ROUTE
HATCH INDICATES
ACCESSIBLE ROUTE
HATCH INDICATES
REFER TO SHEET A2.01 THROUGH A2.03 FOR THE
A0.60
ADDITIONAL GEOMETRY LAYOUT INFORMATION.
WORK POINTS INDICATE CORNER OF EXTERIOR
Issued for Permit & Construction
SHIVE-HATTERY DOCUMENTS FOR CIVIL AND
WALL AND FOUNDATION WALL. REFER TO
FOUNDATION / BRICKLEDGE PLANS FORWORK POINTS TO OUTSIDE CORNER OF
Issued for Code Review
University of Iowa
DESCRIPTION
LANDSCAPE INFORMATION.
2013 Solomon Cordwell Buenz
ASI-004
FOUNDATION WALL.
09.04.201306.07.201305.03.2013
DATE
NO.
1
2.
1.3.
2167584.60, 612691.80
WORK POINT A3.2:
GEOMETRY PLAN
1"=30'
SCALE:
FINISHED FLOOR:
662.0'
2167338.21, 612534.44
WORK POINT A3.1:
2167293.57, 612559.03
WORK POINT A2.2:
FINISHED FLOOR:
662.5'
2167047.46, 612651.01
WORK POINT B1.3:
2166991.07, 612450.83
WORK POINT A1.2:
2166966.99, 612883.30
WORK POINT B2.1:
2167047.17, 612401.66
WORK POINT A2.1:
2167029.17, 612719.24
WORK POINT B2.2:
FINISHED FLOOR:
663.0'
FINISHED FLOOR:
FINISHED FLOOR:
663.0'
FINISHED FLOOR:
E
N 663.0'
I
L
E
S
A
E
2166764.57, 612752.322166782.87, 612684.08
L
-
IWORK POINT B2.3:
WORK POINT B1.2:
E
S
A
H
P
E
N
I
L
N
O
I
T
C
U
R
T
S
2166845.05, 612520.02
N
O
WORK POINT B1.1:
C
F
O
2166721.39, 612718.39
T
I
M
I
L
WORK POINT C.2:
2166672.14, 612790.10
WORK POINT C.1:
FINISHED FLOOR:2166744.68, 612293.472166762.82, 612198.94
PROPERTY CORNER
WORK POINT A1.1:
663.0'BASE POINT #1:
2166680.43, 612667.15
WORK POINT C.3:
A1.01
Issued for Permit & Construction
OPEN-SIDED WALKING SURFACES AND RAMPS
PROVIDE A MIN. OF 12" BETWEEN ALL PLANTS
REFER TO SHIVE-HATTERY DOCUMENTS FOR
GUARDRAILS SHALL BE LOCATED ALONG ALL
UNDERGROUND STORM LINES. DOWNSPOUT
LOCATED BEYOND ALL BUSHES & PLANTING
THAT ARE LOCATED MORE THAN 30 INCHESPROVIDE DOWNSPOUT EXTENSIONS AT ALL
HIGHER VERTICALLY THAN THE FLOOR OREXTENSIONS & SPLASHBLOCK SHOULD BE
LOCATIONS WHICH DO NOT CONNECT TO
GRADE BELOW AND WITHIN 36 INCHES.
Issued for Code Review
CIVIL AND LANDSCAPE INFORMATION.
University of Iowa
SITE ACCESSIBILITY PATHS
AND BUSHES AND HVAC UNITS.
DESCRIPTION
2013 Solomon Cordwell Buenz
06.07.201305.03.2013
DATE
TYPICAL
NO.
2.3.4.
1.
SITE PLAN - PHASE I
1"=50'
SCALE:
.
D
V
L
B
K
E
R
T
N
O
M
R
O
M
E
N
I
L
E
S
A
E
L
E
-
NI
I
L
E
S
N
A
O
I
H
T
P
C
U
R
T
S
N
O
C
F.
O
D
T
I
R
M
I
K
L
R
A
P
E
Y
E
K
W
A
H
PROPERTYBOUNDARY
.T
C E
YE
KW
AH
OPEN-SIDED WALKING SURFACES AND RAMPS
PROVIDE A MIN. OF 12" BETWEEN ALL PLANTS
GUARDRAILS SHALL BE LOCATED ALONG ALL
REFER TO SHIVE-HATTERY DOCUMENTS FOR
UNDERGROUND STORM LINES. DOWNSPOUT
PROVIDE DOWNSPOUT EXTENSIONS AT ALLLOCATED BEYOND ALL BUSHES & PLANTING
THAT ARE LOCATED MORE THAN 30 INCHES
HIGHER VERTICALLY THAN THE FLOOR OREXTENSIONS & SPLASHBLOCK SHOULD BE
LOCATIONS WHICH DO NOT CONNECT TO
GRADE BELOW AND WITHIN 36 INCHES.
A1.02
CIVIL AND LANDSCAPE INFORMATION.
Issued for Permit & Construction
AND BUSHES AND HVAC UNITS.
Issued for Code Review
University of Iowa
SITE ACCESSIBILITY PATHS
DESCRIPTION
2013 Solomon Cordwell Buenz
TYPICAL
06.07.201305.03.2013
DATE
2.3.4.
1.
NO.
ENLARGED SITE PLAN - PHASE I
Y
R
A
D
N
U
O
B
Y
T
R
E
P
O
R
P
1"=30'
SCALE:
"
A
"
130 HAWKEYE COURT130 HAWKEYE COURT
3-STORY BUILDING3-STORY BUILDING
FINISHED FLOOR:
662.0'662.0'662.0'662.0'662.0'
662.0'662.0'
130 HAWKEYE COURT
130 HAWKEYE COURT
130 HAWKEYE COURT130 HAWKEYE COURT
130 HAWKEYE COURT
3-STORY BUILDING
3-STORY BUILDING3-STORY BUILDING
3-STORY BUILDING
3-STORY BUILDING3-STORY BUILDING
3-STORY BUILDING
TRUCK ACCESS LANE
20'-0" MIN. WIDTH
MIN. 7" PCC FIRE
.
REFER TO LANDSCAPE DRAWING
METERS AT END OF BUILDINGS D
V
L
B
FOR SCREENING, TYP.
K
E
R
T
N
O
M
R
O
M
Y
R
A
D
N
U
O
B
Y
T
R
E
P
O
R
P
116 HAWKEYE COURT116 HAWKEYE COURT
3-STORY BUILDING3-STORY BUILDING
FINISHED FLOOR:
662.5'662.5'662.5'662.5'662.5'662.5'662.5'
116 HAWKEYE COURT
116 HAWKEYE COURT116 HAWKEYE COURT
116 HAWKEYE COURT
116 HAWKEYE COURT
3-STORY BUILDING
3-STORY BUILDING3-STORY BUILDING
3-STORY BUILDING3-STORY BUILDING
3-STORY BUILDING3-STORY BUILDING
3-STORY BUILDING
TRASH ENCLOSURE, TYP.
SEE DETAIL 1/A1.30
BIKE RACKS,
TYP.
HANDICAPPEDPARKING SIGN,TYP.
COLLAPSIBLE
BOLLARDS 5'-0" O.C.
172 HAWKEYE COURT172 HAWKEYE COURT172 HAWKEYE COURT172 HAWKEYE COURT
3-STORY BUILDING3-STORY BUILDING3-STORY BUILDING3-STORY BUILDING
FINISHED FLOOR:
663.0'663.0'663.0'663.0'663.0'
663.0'663.0'
102 HAWKEYE COURT102 HAWKEYE COURT102 HAWKEYE COURT102 HAWKEYE COURT
REFER TO LANDSCAPE DRAWING
172 HAWKEYE COURT
172 HAWKEYE COURT
172 HAWKEYE COURT3-STORY BUILDING3-STORY BUILDING
172 HAWKEYE COURTFINISHED FLOOR:FINISHED FLOOR:FINISHED FLOOR:FINISHED FLOOR:FINISHED FLOOR:
FINISHED FLOOR:FINISHED FLOOR:
172 HAWKEYE COURT172 HAWKEYE COURT
172 HAWKEYE COURT
FOR SCREENING, TYPICAL
102 HAWKEYE COURT
102 HAWKEYE COURT102 HAWKEYE COURT
102 HAWKEYE COURT
663.0'
3-STORY BUILDING
102 HAWKEYE COURT
102 HAWKEYE COURT102 HAWKEYE COURT
102 HAWKEYE COURT
3-STORY BUILDING
3-STORY BUILDING3-STORY BUILDING
3-STORY BUILDING
3-STORY BUILDING3-STORY BUILDING
3-STORY BUILDING
CONDENSERS
150'-0" FIRE TRUCK ACCESS LANE
144 HAWKEYE COURT
E
PORTION OF BUILDING BEYOND
3-STORY BUILDING
N
FINISHED FLOOR:
I
L
3-STORY BUILDING
E
S
A
663.0'663.0'663.0'
663.0'
E
L
144 HAWKEYE COURT
-
I
E
S
A
H
3-STORY BUILDING
P
FIRE HYDRANT,TYP.
MIN. 7" PCC FIRETRUCK ACCESS LANE20'-0" MIN. WIDTH(CLOSED TO VEHICULARTRAFFIC)TRAFFIC)
MECH. SCREEN WALL
SEE DETAIL 6/A1.30
BOLLARDS 5'-0" O.C.
COLLAPSIBLE
T
R
U
O
158 HAWKEYE COURT
C
1-STORY BUILDING
FINISHED FLOOR:
E
158 HAWKEYE COURT158 HAWKEYE COURT
158 HAWKEYE COURT158 HAWKEYE COURT
158 HAWKEYE COURT Y
158 HAWKEYE COURT158 HAWKEYE COURT158 HAWKEYE COURT
158 HAWKEYE COURT158 HAWKEYE COURT158 HAWKEYE COURT R
Y
158 HAWKEYE COURT158 HAWKEYE COURT
A
158 HAWKEYE COURT D
158 HAWKEYE COURT
N
158 HAWKEYE COURT158 HAWKEYE COURT158 HAWKEYE COURT
E 663.0'663.0'
158 HAWKEYE COURT158 HAWKEYE COURT158 HAWKEYE COURT U
158 HAWKEYE COURT158 HAWKEYE COURT158 HAWKEYE COURT
158 HAWKEYE COURT158 HAWKEYE COURT
O
B
1-STORY BUILDING
K
Y
T
1-STORY BUILDING
R
FINISHED FLOOR:
E
P
W
O
R
P
FINISHED FLOOR:
A 1-STORY BUILDING1-STORY BUILDINGFINISHED FLOOR:
1-STORY BUILDING1-STORY BUILDING1-STORY BUILDING
H
CONCRETE BENCHPLANTER BEDREFER TO CIVIL DRAWINGS FORSCORED CONCRETE PAVEMENTLAYOUT. MECH. SCREEN WALLSEE DETAIL 6/A1.30
"
A
"
A1.30
FOR 4"X4" STEEL POST.
16" DIA. POURED CONCRETE
5'-6" MIN. EMBEDMENT X
FOR 3"X3" STEEL POST.
12" DIA. POURED CONCRETE
4'-8" MIN. EMBEDMENT X
A2.01
A2.02
A2.03
Issued for Permit & Construction
MAINTAIN 2" MIN. BETWEEN SIDEWALK AND
MAINTAIN 2" MIN. BETWEEN GRADE ANDMAINTAIN 6" MIN. BETWEEN GRADE AND
Issued for Code Review
University of Iowa
DESCRIPTION
2013 Solomon Cordwell Buenz
SIDING PRODUCTS, TYPICAL.SIDING PRODUCTS, TYPICAL.
ASI-004
BRICK LEDGE, TYPICAL.
09.04.201306.07.201305.03.2013
DATE
NO.
1
1.2.3.
ENLARGED FOUNDATION/BRICKLEDGE PLAN AT WORK POINT
FACE OF BRICK / FACE OF FDN.
BUILDING C - FOUNDATION/BRICKLEDGE PLAN
FACE OF SLAB EDGE
FACE OF SIDING
FACE OF FDN.
1/8"=1'-0"
ASI-004
SCALE:
09.04.2013
1"=1'-0"
SCALE:
1
FACE OF FDN.FACE OF SIDINGFACE OF SLAB EDGE
FACE OF BRICK / FACE OF FDN.
ENLARGED FOUNDATION/BRICKLEDGE PLAN AT WORK POINTENLARGED FOUNDATION/BRICKLEDGE PLAN AT WORK POINT
FACE OF SLAB EDGE
ENLARGED FOUNDATION/BRICKLEDGE PLAN AT ENTRY
FACE OF SIDING
FACE OF SLAB EDGE
FACE OF FDN.FACE OF BRICK / FACE OF FDN.FACE OF BRICK / FACE OF FDN.
FACE OF SIDING
FACE OF FDN.
FACE OF SLAB EDGEFACE OF SLAB EDGE
FACE OF SLAB EDGE
FACE OF SIDING
FACE OF FDN.
1"=1'-0"1"=1'-0"1"=1'-0"
SCALE:SCALE:SCALE:
A2.10
UPUP
DN
DN
UP
UP
REFER TO PLUMBING DRAWINGS FOR ALL FLOOREXPANSION JOINT LOCATIONS. REFER TO SHEET
REFER TO SHEET A0.40 FOR FULL ACCESSIBILITY
SEE SHEETS A6.30 THROUGH A6.32 FOR TYPE 'B'
REFER TO MECHANICAL DRAWINGS FOR FLOOR
A2.11
Issued for Permit & Construction
SEE SHEETS A6.40 THROUGH A6.42 FOR FULLY
MATRIX THAT LISTS LOCATIONS OF EACH UNIT
SEE SHEET A8.10 FOR DOOR SCHEDULES AND
SEE A3 SHEETS FOR MORE INFORMATION ON
SEE SHEET A8.01 FOR PARTITION DETAILS.
ACCESSIBLE UNITS PER MATRIX ON A0.40
ADAPTABLE UNITS PER MATRIX ON A0.40
TYPE AND UNITS FOR INSTALLATION OF
Issued for Code Review
University of Iowa
COMMUNICATION FEATURES.DESCRIPTION
2013 Solomon Cordwell Buenz
A4.32 FOR PLAN DETAILS.
ASI-004
DRAIN LOCATIONS.
PAD LOCATIONS.
09.04.201306.07.201305.03.2013
DATE
DETAILS.
NO.
1
4.
1.2.3.5.6.7.8.
CJ
- REFER TO SHEET A0.40
- REFER TO SHEET A6.31- REFER TO SHEET A6.41
FOR ACCESSIBLE UNITFOR ACCESSIBLE UNIT
CJCJ
FOR TYPICAL UNIT
COMMUNICATION
TYP
FEATURED UNIT
FECLOCATIONS &
HEADER
LOCATIONS.
BUILDINGS A1, A2, & A3 - PARTIAL FIRST FLOOR PLAN
EXAMPLE.EXAMPLE.
BATH
CJ
M
O
O
R
D
CLOSET
E
B
LIVING ROOM
CLOSET
CJ
CJCJ
CLOSET
CJ
KITCHEN
LIVING ROOM
TYP
BEDROOM
KITCHENLAUNDRY
CLOSET
LAUNDRYLAUNDRY
CJ
TYP
1/4"=1'-0"
CJ
- REFER TO SHEET A6.30- REFER TO SHEET A0.40- REFER TO SHEET A6.40
FOR ACCESSIBLE UNITFOR ACCESSIBLE UNIT
SCALE:
FOR TYPICAL UNIT
COMMUNICATION
CLOSET
CLOSET
FEATURED UNIT
LOCATIONS &
BEDROOM
LOCATIONS.
BATH
CLOSET
EXAMPLE.EXAMPLE.
BEDROOM
BATH
CJ
CJCJ
LIVING ROOMKITCHENKITCHENLIVING ROOM
CJ
CJ
CLOSETCLOSET
BEDROOMBATHBATHBEDROOM
LAUNDRYLAUNDRY
LAUNDRY
LAUNDRY
LAUNDRY
BATHBATH
BEDROOM
M
O
O
R
D
CLOSETCLOSET
E
TYP
B
CJ
CJ
TYP
CJ
CLOSETCLOSET
CJ
LIVING ROOMLIVING ROOM
KITCHENKITCHEN
LAUNDRYLAUNDRYLAUNDRYCJ
LAUNDRY
CJ
CJ
CJ
CLOSETCLOSET
BEDROOMBEDROOM
BATHBATH
CJ
CJ
- REFER TO SHEET A6.32- REFER TO SHEET A0.40- REFER TO SHEET A6.42
FOR ACCESSIBLE UNITFOR ACCESSIBLE UNIT
FOR TYPICAL UNIT
COMMUNICATION
FEATURED UNIT
LIVING ROOMKITCHENKITCHENLIVING ROOM
LOCATIONS &
LOCATIONS.
EXAMPLE.EXAMPLE.
CJ
CJ
CLOSETCLOSET
BEDROOMBATHBATHBEDROOM
CARPET TRANSITION
QUARTER TURN AT
DOOR OPERATOR
LAUNDRYLAUNDRY
LAUNDRY
LAUNDRY
CARPET TRANSITION
HAND
QUARTER TURN AT
CJCJ
OPP
TYP
SIM.
DOOR OPERATOR
LINE OF CANOPY
CJ
E-BRK-01BELOW, TYP.E-FCB-01,TYP.
ABOVE
HAND
OPP
TYP
REFER TO PLUMBING DRAWINGS FOR ALL FLOOREXPANSION JOINT LOCATIONS. REFER TO SHEET
REFER TO SHEET A0.40 FOR FULL ACCESSIBILITY
A2.12
SEE SHEETS A6.30 THROUGH A6.32 FOR TYPE 'B'
REFER TO MECHANICAL DRAWINGS FOR FLOOR
Issued for Permit & Construction
SEE SHEETS A6.40 THROUGH A6.42 FOR FULLY
MATRIX THAT LISTS LOCATIONS OF EACH UNIT
SEE SHEET A8.10 FOR DOOR SCHEDULES AND
SEE A3 SHEETS FOR MORE INFORMATION ON
SEE SHEET A8.01 FOR PARTITION DETAILS.
ACCESSIBLE UNITS PER MATRIX ON A0.40
ADAPTABLE UNITS PER MATRIX ON A0.40
TYPE AND UNITS FOR INSTALLATION OF
Issued for Code Review
University of Iowa
COMMUNICATION FEATURES.DESCRIPTION
2013 Solomon Cordwell Buenz
A4.32 FOR PLAN DETAILS.
ASI-004
DRAIN LOCATIONS.
PAD LOCATIONS.
09.04.201306.07.201305.03.2013
DATE
DETAILS.
NO.
1
4.
1.2.3.5.6.7.8.
TYPTYP
TYPTYP
CJ
CJ
CJ
CJ
FEC
BUILDINGS A1, A2, & A3 - PARTIAL FIRST FLOOR PLAN
BEDROOMBEDROOM
BATHBATH
CLOSET
CLOSET
CLOSET
CJ
UTILITYCLOSET
UTILITY
TYP
CJ
LAUNDRY
LAUNDRY
CJ
KITCHENKITCHENCJ
LIVING ROOMLIVING ROOM
CJ
CJCLOSETCLOSET
CLOSETCLOSET
CLOSETCLOSET
UTILITYUTILITY
CJ
1/4"=1'-0"
CJ
CLOSETCLOSET
SCALE:
BEDROOMBEDROOM
BATHBATH
BATHBATH
BEDROOMBEDROOM
CLOSETCLOSET
TYP
CLOSETCLOSETCLOSET
UTILITYCLOSET
UTILITY
CJ
CJ
CJ
CLOSETCLOSET
CJ
LIVING ROOMLIVING ROOM
KITCHENKITCHEN
CJ
CJ
LAUNDRYLAUNDRY
CLOSET
UTILITYCLOSET
UTILITY
CJ
CJ
FEC
CLOSETCLOSET
BEDROOMBEDROOM
BATHBATH
LAUNDRYLAUNDRY
LAUNDRY
BEDROOMBEDROOM
BATHBATH
CLOSETCLOSET
CJ
CJ
LIVING ROOMLIVING ROOM
KITCHENKITCHEN
TYP
CLOSET
UTILITY
CLOSET
UTILITY
CJCJ
CJ
BEDROOM
BATH
CLOSETBEDROOM
BATH
CLOSET
CLOSET
CLOSET
UTILITY
CJ
CLOSET
UTILITY
CJ
LAUNDRY
CLOSET
LAUNDRY
KITCHENBEDROOM
LIVING ROOM
KITCHEN
CJ
CLOSET
CJCJ
LIVING ROOM
CLOSET
CLOSET
CJUTILITY
UTILITYCLOSET
CLOSET
CLOSETCLOSET
UTILITY
BEDROOM
BATH
CJ
HEADER
FEC
CJ
CJ
E-BRK-01BELOW, TYP.E-FCB-01,TYP.
CJ
REFER TO PLUMBING DRAWINGS FOR ALL FLOOREXPANSION JOINT LOCATIONS. REFER TO SHEET
REFER TO SHEET A0.40 FOR FULL ACCESSIBILITY
A2.13
SEE SHEETS A6.30 THROUGH A6.32 FOR TYPE 'B'
REFER TO MECHANICAL DRAWINGS FOR FLOOR
Issued for Permit & Construction
SEE SHEETS A6.40 THROUGH A6.42 FOR FULLY
MATRIX THAT LISTS LOCATIONS OF EACH UNIT
SEE SHEET A8.10 FOR DOOR SCHEDULES AND
SEE A3 SHEETS FOR MORE INFORMATION ON
SEE SHEET A8.01 FOR PARTITION DETAILS.
ACCESSIBLE UNITS PER MATRIX ON A0.40
ADAPTABLE UNITS PER MATRIX ON A0.40
TYPE AND UNITS FOR INSTALLATION OF
Issued for Code Review
University of Iowa
COMMUNICATION FEATURES.DESCRIPTION
2013 Solomon Cordwell Buenz
A4.32 FOR PLAN DETAILS.
ASI-002
DRAIN LOCATIONS.
PAD LOCATIONS.
08.01.201306.07.201305.03.2013
DATE
DETAILS.
NO.
1
4.
1.2.3.5.6.7.8.
BUILDINGS A1, A2, & A3 - PARTIAL TYPICAL FLOOR PLAN
FEC
BATH
BEDROOM
CLOSET
UTILITY
CLOSET
LIVING ROOM
CLOSETCLOSET
CLOSET
UTILITY
CLOSET
KITCHEN
LIVING ROOM
TYP
BEDROOM
KITCHEN
LAUNDRY
CLOSET
LAUNDRYLAUNDRY
CLOSET
UTILITY
CLOSET
UTILITY
1/4"=1'-0"
CLOSETSCALE:
T
E
S
BEDROOM
BATH
O
CLOSETL
C
BEDROOM
BATH
CLOSETCLOSET
UTILITYUTILITY
LIVING ROOMKITCHENKITCHENLIVING ROOM
CLOSETCLOSETCLOSETCLOSETCLOSETCLOSET
CLOSET
BEDROOMBATHBATHBEDROOM
LAUNDRYLAUNDRY
LAUNDRY
BATHBATH
BEDROOMBEDROOM
CLOSETCLOSET
FEC
TYP
CLOSETCLOSET
CLOSET
UTILITYCLOSETUTILITY
CLOSETCLOSET
LIVING ROOMLIVING ROOM
KITCHENKITCHEN
LAUNDRYLAUNDRYLAUNDRY
LAUNDRY
CLOSETCLOSET
UTILITYUTILITY
CLOSETCLOSET
BEDROOMBEDROOM
BATHBATH
CLOSETCLOSET
UTILITYUTILITY
LIVING ROOMKITCHENKITCHENLIVING ROOM
CLOSETCLOSETCLOSETCLOSET
CLOSETCLOSETCLOSET
BEDROOMBATHBATHBEDROOM
LAUNDRYLAUNDRY
HAND
TYP.
OPP
LAUNDRY
DS
DS
DS
1/41/4
1/4
12
E-CANOPY-01E-MTL-05
E-FCB-01,TYP.
LINE OF ROOFABOVE, TYP.
REFER TO PLUMBING DRAWINGS FOR ALL FLOOREXPANSION JOINT LOCATIONS. REFER TO SHEET
REFER TO SHEET A0.40 FOR FULL ACCESSIBILITY
A2.14
SEE SHEETS A6.30 THROUGH A6.32 FOR TYPE 'B'
REFER TO MECHANICAL DRAWINGS FOR FLOOR
Issued for Permit & Construction
SEE SHEETS A6.40 THROUGH A6.42 FOR FULLY
MATRIX THAT LISTS LOCATIONS OF EACH UNIT
SEE SHEET A8.10 FOR DOOR SCHEDULES AND
SEE A3 SHEETS FOR MORE INFORMATION ON
SEE SHEET A8.01 FOR PARTITION DETAILS.
ACCESSIBLE UNITS PER MATRIX ON A0.40
ADAPTABLE UNITS PER MATRIX ON A0.40
TYPE AND UNITS FOR INSTALLATION OF
Issued for Code Review
University of Iowa
COMMUNICATION FEATURES.DESCRIPTION
2013 Solomon Cordwell Buenz
A4.32 FOR PLAN DETAILS.
ASI-002
DRAIN LOCATIONS.
PAD LOCATIONS.
08.01.201306.07.201305.03.2013
DATE
DETAILS.
NO.
1
4.
1.2.3.5.6.7.8.
TYP.
TYP.
FECFEC
BUILDINGS A1, A2, & A3 - PARTIAL TYPICAL FLOOR PLAN
BEDROOMBEDROOM
BATHBATH
CLOSETCLOSET
CLOSETCLOSET
UTILITYUTILITY
LAUNDRYLAUNDRY
KITCHENKITCHEN
LAUNDRY
LIVING ROOMLIVING ROOM
CLOSETCLOSET
CLOSET
CLOSETCLOSET
UTILITY
UTILITY
1/4"=1'-0"
UTILITYCLOSETUTILITYCLOSET
CLOSETCLOSET
SCALE:
BEDROOMBEDROOM
BATHBATH
BATHBATH
BEDROOMBEDROOM
CLOSETCLOSET
TYP
CLOSETCLOSETCLOSET
UTILITYCLOSET
UTILITY
CLOSETCLOSET
LIVING ROOMLIVING ROOM
KITCHENKITCHEN
LAUNDRYLAUNDRY
LAUNDRYLAUNDRY
CLOSETCLOSET
UTILITYUTILITY
CLOSETFECCLOSET
BEDROOMBEDROOM
BATHBATH
LAUNDRYLAUNDRY
LAUNDRY
LAUNDRY
LAUNDRY
BEDROOMBEDROOM
CLOSET
BATHBATH
CLOSET
LIVING ROOMLIVING ROOM
KITCHENKITCHEN
CLOSETCLOSET
UTILITYUTILITY
BATH
CLOSETBEDROOM
BEDROOM
BATH
CLOSET
CLOSET
CLOSET
UTILITY
CLOSET
UTILITY
LAUNDRY
CLOSET
LAUNDRY
BEDROOM
LAUNDRY
KITCHEN
LIVING ROOM
KITCHEN
CLOSET
LIVING ROOM
CLOSET
CLOSETCLOSET
UTILITY
UTILITYCLOSET
CLOSET
CLOSET
UTILITY
BEDROOM
BATH
FEC
E-FCB-01,TYP.LINE OF ROOFABOVE, TYP.E-BRK-01BELOW, TYP.
A2.15
SPACE. 50% MUST BE AT EAVE & 50% MUST BE Issued for Permit & Construction
SEE SHEET A4.32 FOR TYPICAL ROOF DETAILS.REFER TO MECHANICAL/PLUMBING DRAWINGSLOCATE ALL ROOF VENTS MINIMUM 18" APART.
BARRIER) @ ALL ROOF PERIMETER (4'-0" MIN.
(COLOR TO BE APPROVED BY ARCHITECT TO
ROOF VENTING TO BE 1/300 AREA OF ATTICSOFFIT VENTS MUST PROVIDE 5 SQ. IN. PER
RIDGE VENT MUST PROVIDE 18 SQ. IN. PER
ATTACHMENT DEVICES AS REQUIRED, ALL
PENETRATIONS THROUGH SHINGLE ROOF
PROVIDE E-WP-04 (SELF-ADHEARING AIRFOR EQUIPMENT INSTALLATION DETAILS
PREFINISHED TO MATCH GUTTERS AND
PROVIDE GUTTER CAPS, SPLICES, AND
Issued for Code Review
LINEAL FOOT MIN. TO MEET VENTING
LINEAL FOOT MIN. TO MEET VENTING
University of Iowa
CONTRACTOR TO PAINT ALL ROOF
MATCH ROOF SHINGLE COLOR).
DESCRIPTION
2013 Solomon Cordwell Buenz
FROM EDGE OF ROOF).ASI-003
REQUIREMENTS.REQUIREMENTS.
AT RIDGE VENT.
DOWNSPOUTS.
08.14.201306.07.201305.03.2013
DATE
NO.
1
2.3.4.5.6.7.8.9.
1.
LINE OF BUILDINGSEE DETAIL 3/A4.30 FOR
TYPICAL GUTTER SIZE
BELOW, TYP.
E-ROOF-01,
TYP.
L.P.
L.P.
DS
TYP.
H.P.
DS
BUILDINGS A1, A2, & A3 - ENLARGED ROOF PLAN
H.P.
DS
L.P.
DS
L.P.
BUILDINGS A1, A2, & A3 - ROOF PLAN
L.P.
L.P.
CRICKET, TYP.
E-ROOF-01,
E-ROOF-01
TYP.
DS
DSDS
H.P.44H.P.
1212
H.P.
CRICKET, TYP.
CRICKET, TYP.
DSDS
E-ROOF-01,
DSE-ROOF-01
H.P.
TYP.
4
12
L.P.L.P.
1/16"=1'-0"
3/32"=1'-0"
SCALE:
L.P.
H.P.
DSDS
DS
H.P.
H.P.
L.P.
4
SCALE:
44
12
1212
L.P.
TYP.DS
DS
DS
DS
L.P.
DS
DSDS
H.P.H.P.
TYP.TYP.
TYP.
TYP.
DSDS
DS
L.P.L.P.
H.P.
H.P.
DSDS
H.P.H.P.
SEE DETAIL 15/A4.32
ROOF VENT, TYP.
DSDS
L.P.
L.P.L.P.
44
1212
DS
L.P.
H.P.
H.P.
DS
H.P.
44
1212DS
TYP.
DS
L.P.
L.P.
CRICKET, TYP.CRICKET, TYP.
E-ROOF-01,E-ROOF-01,
E-ROOF-01E-ROOF-01
TYP.TYP.
DSDS
H.P.H.P.
44
121212
TYP.
TYP.
DSDS
L.P.L.P.
DSDS
TYP.
44
H.P.
L.P.
12
1212
DSDS
A2.20
Issued for Permit & Construction
SEE SHEET A8.10 FOR WINDOW SCHEDULE
Issued for Code Review
University of Iowa
DESCRIPTION
2013 Solomon Cordwell Buenz
TYPE AND SIZE INFORMATION
ASI-001
07.31.201306.07.201305.03.2013
DATE
NO.
1
1.
TYP.TYP.
BLDG. B2
DSDSDSDSDSDS
BLDG. B1
DS
BUILDINGS B1 & B2 - FIRST FLOOR PLAN
DS
DSDS
DS
1/8"=1'-0"
DSDSDSDS
TYP.
TYP.
SCALE:
DS
DS
DS
DS
DS
TYP.TYP.
DS
DS
TYP.TYP.
DS
DS
DS
DSDS
DS
DSDS
DS
DS
DS
DS
DS
DS
DS
DS
SEE SHEET A8.10 FOR WINDOW SCHEDULE TYPE
A2.21
Issued for Permit & Construction
Issued for Code Review
University of Iowa
DESCRIPTION
2013 Solomon Cordwell Buenz
AND SIZE INFORMATION.
ASI-001
07.31.201306.07.201305.03.2013
DATE
NO.
1
1.
TYP.TYP.
TYP.TYP.
BLDG. B2
DSDSDSDSDSDS
BLDG. B1
DS
BUILDINGS B1 & B2 - TYPICAL FLOOR PLAN
DS
DS
DS
DSDSDSDS
DS
1/8"=1'-0"
TYP.
TYP.
SCALE:
DS
DS
DS
DS
TYP.TYP.
SIM.
DS
DS
TYP.TYP.
SIM.
DS
DS
DS
DSDSDS
DS
DS
DS
DS
DS
DS
DS
DS
DS
UP
REFER TO PLUMBING DRAWINGS FOR ALL FLOOREXPANSION JOINT LOCATIONS. REFER TO SHEET
REFER TO SHEET A0.40 FOR FULL ACCESSIBILITY
A2.22
SEE SHEETS A6.30 THROUGH A6.32 FOR TYPE 'B'
REFER TO MECHANICAL DRAWINGS FOR FLOOR
Issued for Permit & Construction
SEE SHEETS A6.40 THROUGH A6.42 FOR FULLY
MATRIX THAT LISTS LOCATIONS OF EACH UNIT
SEE SHEET A8.10 FOR DOOR SCHEDULES AND
SEE A3 SHEETS FOR MORE INFORMATION ON
SEE SHEET A8.01 FOR PARTITION DETAILS.
ACCESSIBLE UNITS PER MATRIX ON A0.40
ADAPTABLE UNITS PER MATRIX ON A0.40
TYPE AND UNITS FOR INSTALLATION OF
Issued for Code Review
University of Iowa
COMMUNICATION FEATURES.DESCRIPTION
2013 Solomon Cordwell Buenz
A4.32 FOR PLAN DETAILS.
ASI-004ASI-002
DRAIN LOCATIONS.
PAD LOCATIONS.
09.04.201308.01.201306.07.201305.03.2013
DATE
DETAILS.
NO.
2
1
4.
1.2.3.5.6.7.8.
- REFER TO SHEET A6.32- REFER TO SHEET A0.40- REFER TO SHEET A6.42
FOR ACCESSIBLE UNITFOR ACCESSIBLE UNIT
FOR TYPICAL UNIT
COMMUNICATION
FEATURED UNIT
LOCATIONS &
LOCATIONS.
"A"
BELOW, TYP.EXAMPLE.EXAMPLE.
E-FCB-01,
E-BRK-01
BLDG. B2
TYP.
BLDG. B1
TYP.
CJCJ
CJCJ
BUILDINGS B1 & B2 - PARTIAL FIRST FLOOR PLAN
CJCJCJ
CJ
CJCJ
CJ
TYP.
SIM.
CLOSETCLOSETCLOSETCLOSET
BEDROOMBEDROOM
CLOSETCLOSET
LIVING ROOMLIVING ROOMLIVING ROOM
BEDROOMBEDROOMBEDROOMBEDROOM
LAUNDRYLAUNDRYLAUNDRY
CLOSETCLOSET
CLOSETCLOSET
KITCHENKITCHEN
BATHBATHBATHBATH
KITCHEN
CJ
BATH
CLOSETCLOSETCLOSETCLOSETCLOSET
UTILITYUTILITYUTILITYUTILITYUTILITY
CLOSET
UTILITY
1/4"=1'-0"
SCALE:
FEC
UTILITYCLOSETUTILITYCLOSET
UTILITYCLOSETUTILITYCLOSETUTILITYCLOSETUTILITYCLOSET
BATH
BATHBATH
BATH
BATH
KITCHENKITCHENKITCHENKITCHEN
KITCHEN
KITCHEN
KITCHEN
KITCHENKITCHENKITCHENKITCHEN
KITCHEN
KITCHEN
KITCHEN
KITCHEN
KITCHEN
KITCHEN
KITCHENKITCHEN
KITCHEN
BATHKITCHENBATH
KITCHEN
KITCHEN
KITCHEN
CLOSET
CLOSETLAUNDRYCLOSETLAUNDRYCLOSETLAUNDRYCLOSET
TYP.
SIM.
LIVING ROOMLIVING ROOM
LIVING ROOMBEDROOM
BEDROOM
LIVING ROOM
CLOSETCLOSET
CLOSETCLOSET
BEDROOMBEDROOMBEDROOMBEDROOM
TYP.
CLOSETCLOSETSIM.
BEDROOM
BEDROOM
CLOSETCLOSET
CJ
CJ
CJ
CJCJCJ
CJ
CJCJ
CJ
- REFER TO SHEET A0.40
- REFER TO SHEET A6.31- REFER TO SHEET A6.41
FOR ACCESSIBLE UNITFOR ACCESSIBLE UNIT
"A"
FOR TYPICAL UNIT
COMMUNICATION
FEATURED UNIT
LOCATIONS &
LOCATIONS.
EXAMPLE.EXAMPLE.
"A"
CJCJ
CJ
BLDG. B2
CJ
BLDG. B1
LIVING ROOM
BEDROOM
- REFER TO SHEET A6.30- REFER TO SHEET A0.40- REFER TO SHEET A6.40
FOR ACCESSIBLE UNITFOR ACCESSIBLE UNIT
CLOSET
FOR TYPICAL UNIT
COMMUNICATION
LAUNDRY
FEATURED UNIT
LOCATIONS &
LOCATIONS.
BUILDINGS B1 & B2 - PARTIAL FIRST FLOOR PLAN
EXAMPLE.EXAMPLE.
CJ
KITCHEN
TYP.
SIM.
BATH
TYP.
SIM.
UTILITY
CJCLOSET
CLOSET
FEC
FECFEC
FEC
FEC
CJ
CARPET TRANSITION
QUARTER TURN AT
FIRE CONTROL PANEL
SEE DETAIL 9/A1.30DOOR OPERATOR
DOOR OPERATOR
LINE OF CANOPY
1/4"=1'-0"
FIRE BELL
ABOVE
SCALE:
CARPET TRANSITION
QUARTER TURN AT
BELOW, TYP.
E-FCB-01,
E-BRK-01
TYP.
TYP.
TYP.
CJCJCJ
CJ
"A"
REFER TO PLUMBING DRAWINGS FOR ALL FLOOREXPANSION JOINT LOCATIONS. REFER TO SHEET
REFER TO SHEET A0.40 FOR FULL ACCESSIBILITY
A2.23
SEE SHEETS A6.30 THROUGH A6.32 FOR TYPE 'B'
REFER TO MECHANICAL DRAWINGS FOR FLOOR
Issued for Permit & Construction
SEE SHEETS A6.40 THROUGH A6.42 FOR FULLY
MATRIX THAT LISTS LOCATIONS OF EACH UNIT
SEE SHEET A8.10 FOR DOOR SCHEDULES AND
SEE A3 SHEETS FOR MORE INFORMATION ON
SEE SHEET A8.01 FOR PARTITION DETAILS.
ACCESSIBLE UNITS PER MATRIX ON A0.40
ADAPTABLE UNITS PER MATRIX ON A0.40
TYPE AND UNITS FOR INSTALLATION OF
Issued for Code Review
University of Iowa
COMMUNICATION FEATURES.DESCRIPTION
2013 Solomon Cordwell Buenz
A4.32 FOR PLAN DETAILS.
ASI-004ASI-002
DRAIN LOCATIONS.
PAD LOCATIONS.
09.04.201308.01.201306.07.201305.03.2013
DATE
DETAILS.
NO.
2
1
4.
1.2.3.5.6.7.8.
BLDG. B2BLDG. B2
CJ
BLDG. B1BLDG. B1
CJ
CLOSETCLOSET
UTILITYUTILITY
LIVING ROOMLIVING ROOM
BUILDINGS B1 & B2 - PARTIAL FIRST FLOOR PLAN
KITCHENKITCHEN
BUILDINGS B1 & B2 - PARTIAL FIRST FLOOR PLAN
CJ
CJ
CLOSETCLOSETCLOSETCLOSETCLOSETCLOSET
BEDROOMBATHBATHBEDROOM
FEC
LAUNDRYLAUNDRY
LAUNDRYLAUNDRY
BEDROOMBEDROOM
BATHBATH
CLOSETCLOSET
1/4"=1'-0"
1/4"=1'-0"
SCALE:
CLOSET
CLOSET
UTILITY
UTILITYCJ
TYP.TYP.
TYP.TYP.
CJ
SCALE:
CJCJ
LAUNDRYLAUNDRYLAUNDRY
CJ
KITCHENKITCHEN
CJ
CJ
CJ
LIVING ROOMLIVING ROOM
CJ
CLOSETCLOSET
CJ
UTILITYUTILITY
LIVING ROOMLIVING ROOM
KITCHENKITCHENCLOSETCLOSET
CJ
CJ
CJ
CLOSET
CLOSET
CLOSETCLOSET
UTILITYUTILITY
CJ
CJ
CJ
CLOSETCLOSET
BEDROOMBEDROOM
CLOSETCLOSET
BATHBATH
BEDROOMBEDROOM
BATHBATH
LAUNDRYLAUNDRY
BATHBATH
BEDROOMBEDROOM
BEDROOMBATHBATHBEDROOM
CLOSETCLOSET
TYP.
E-BRK-01BELOW, TYP.BELOW, TYP.E-BRK-01BELOW, TYP.E-FCB-01,TYP.
TYP.
E-FCB-01,
CLOSETCLOSET
CLOSETCLOSETCLOSETCLOSET
UTILITYUTILITY
CJ
FEC
CJ
CLOSET
CLOSETCJ
UTILITY
UTILITY
CLOSETCLOSET
CJ
CJ
CJ
LAUNDRYLAUNDRY
LIVING ROOMLIVING ROOM
KITCHENKITCHEN
CJ
LAUNDRY
CJ
TYP.
KITCHENKITCHEN
LIVING ROOMLIVING ROOM
LAUNDRYLAUNDRY
CJ
CJ
LAUNDRYLAUNDRY
LAUNDRY
CJ
CJ
CLOSETCLOSET
CLOSET
CLOSET
UTILITYUTILITY
CJ
CJ
CLOSETCLOSET
CLOSET
CLOSETCLOSETCLOSET
CJUTILITY
UTILITY
FEC
CJ
UTILITYCLOSET
BEDROOMBEDROOM
CLOSETCLOSET
BATHBATH
BEDROOMBEDROOM
BATHBATH
LAUNDRYLAUNDRY
CJ
LAUNDRY
LAUNDRY
BEDROOMBEDROOM
BEDROOM
BATH
BATHBATH
CLOSETCLOSET
CLOSETBEDROOM
BATH
CLOSETCLOSET
CJ
CJ
CLOSET
UTILITY
CJ
CLOSET
UTILITY
HAND
OPP.
LAUNDRYTYP.
LIVING ROOMKITCHENKITCHENLIVING ROOM
CLOSET
LAUNDRY
KITCHEN
BEDROOM
CJLAUNDRY
TYP.
CLOSET
CLOSET
UTILITYUTILITY
LIVING ROOMCJ
KITCHEN
CJ
CJ
CLOSET
CJ
CJ
CJ
CJ
LIVING ROOM
CLOSET
CLOSET
CLOSET
CJUTILITY
UTILITYCLOSET
CLOSET
CLOSET
CLOSET
UTILITY
BEDROOM
CJ
BATH
TYP.
SIM.
FEC
CJCJ
CJ
REFER TO PLUMBING DRAWINGS FOR ALL FLOOREXPANSION JOINT LOCATIONS. REFER TO SHEET
REFER TO SHEET A0.40 FOR FULL ACCESSIBILITY
A2.24
SEE SHEETS A6.30 THROUGH A6.32 FOR TYPE 'B'
REFER TO MECHANICAL DRAWINGS FOR FLOOR
Issued for Permit & Construction
SEE SHEETS A6.40 THROUGH A6.42 FOR FULLY
MATRIX THAT LISTS LOCATIONS OF EACH UNIT
SEE SHEET A8.10 FOR DOOR SCHEDULES AND
SEE A3 SHEETS FOR MORE INFORMATION ON
SEE SHEET A8.01 FOR PARTITION DETAILS.
ACCESSIBLE UNITS PER MATRIX ON A0.40
ADAPTABLE UNITS PER MATRIX ON A0.40
TYPE AND UNITS FOR INSTALLATION OF
Issued for Code Review
University of Iowa
COMMUNICATION FEATURES.DESCRIPTION
2013 Solomon Cordwell Buenz
A4.32 FOR PLAN DETAILS.
ASI-002
DRAIN LOCATIONS.
PAD LOCATIONS.
08.01.201306.07.201305.03.2013
DATE
DETAILS.
NO.
1
4.
1.2.3.5.6.7.8.
"A"
E-FCB-01,
BLDG. B2
TYP.
BLDG. B1
BUILDINGS B1 & B2 - PARTIAL TYPICAL FLOOR PLAN
BEDROOM
BEDROOM
LIVING ROOMCLOSETLIVING ROOMCLOSET
BEDROOMBEDROOMBEDROOMBEDROOM
CLOSETCLOSETTYP.
SIM.
LIVING ROOMCLOSETCLOSET
CLOSET
CLOSET
LAUNDRY
LAUNDRY
LAUNDRY
CLOSET
CLOSET
LAUNDRY
LAUNDRY
KITCHENKITCHEN
KITCHEN
CLOSETCLOSET
CLOSET
CLOSET
BATHBATH
BATHBATH
BATH
CLOSET
UTILITY
CLOSETCLOSETCLOSETCLOSETCLOSET
CLOSET
UTILITYUTILITYUTILITYUTILITYUTILITY
1/4"=1'-0"
SCALE:
FECFEC
CLOSETCLOSETCLOSET
UTILITY
UTILITYUTILITY
CLOSETCLOSET
UTILITYUTILITY
CLOSET
UTILITY
BATHBATH
BATH
BATH
BATH
BATH
KITCHEN
KITCHEN
KITCHENCLOSET
KITCHEN
KITCHEN
KITCHEN
KITCHEN
KITCHENKITCHENKITCHEN
KITCHENKITCHEN
KITCHEN
KITCHEN
KITCHEN
CLOSET
CLOSET
KITCHEN
CLOSETCLOSETCLOSET
LAUNDRY
LAUNDRY
CLOSETLAUNDRYCLOSET
LAUNDRYCLOSET
LAUNDRYLAUNDRY
CLOSET
CLOSETCLOSET
LIVING ROOMLIVING ROOM
CLOSET
LIVING ROOM
BEDROOMBEDROOM
CLOSETCLOSETCLOSETCLOSET
CLOSET
BEDROOMBEDROOM
BEDROOMBEDROOM
CLOSETCLOSETCLOSET
CLOSETCLOSET
CLOSET
"A"
"A"
BLDG. B2
CLOSET
LIVING ROOM
BLDG. B1
BEDROOM
BUILDINGS B1 & B2 - PARTIAL TYPICAL FLOOR PLAN
E-FCB-01,
LAUNDRY
TYP.
KITCHEN
BATH
CLOSETCLOSET
UTILITY
FEC
CARPET TRANSITION
QUARTER TURN AT
1/4"=1'-0"
E-MTL-05
SCALE:
CARPET TRANSITION
QUARTER TURN AT
1/41/4
1212
1212
E-MTL-05
E-CANOPY-01
DS
E-CANOPY-01
CLOSETCLOSET
UTILITYUTILITY
TYP.
SIM.
"A"
A2.25
A4
A2.26
SPACE. 50% MUST BE AT EAVE & 50% MUST BE
Issued for Permit & Construction
SEE SHEET A4.32 FOR TYPICAL ROOF DETAILS.LOCATE ALL ROOF VENTS MINIMUM 18" APART.
REFER TO MECHANICAL/PLUMBING DRAWINGS
BARRIER) @ ALL ROOF PERIMETER (4'-0" MIN.(COLOR TO BE APPROVED BY ARCHITECT TO
SOFFIT VENTS MUST PROVIDE 5 SQ. IN. PER
ROOF VENTING TO BE 1/300 AREA OF ATTIC
RIDGE VENT MUST PROVIDE 18 SQ. IN. PER
ATTACHMENT DEVICES AS REQUIRED, ALL
PENETRATIONS THROUGH SHINGLE ROOF
PROVIDE E-WP-04 (SELF-ADHEARING AIRFOR EQUIPMENT INSTALLATION DETAILS
PREFINISHED TO MATCH GUTTERS AND
PROVIDE GUTTER CAPS, SPLICES, AND
Issued for Code Review
LINEAL FOOT MIN. TO MEET VENTING
LINEAL FOOT MIN. TO MEET VENTING
University of Iowa
CONTRACTOR TO PAINT ALL ROOF
MATCH ROOF SHINGLE COLOR).
DESCRIPTION
2013 Solomon Cordwell Buenz
FROM EDGE OF ROOF).
ASI-003
REQUIREMENTS.REQUIREMENTS.
AT RIDGE VENT.
DOWNSPOUTS.
08.14.201306.07.201305.03.2013
DATE
NO.
1
2.4.
1.3.5.6.7.8.9.
L.P.
DS
BLDG. B2BLDG. B2
H.P.
H.P.H.P.
L.P.L.P.L.P.L.P.
BLDG. B1BLDG. B1
DSDSDSDSDSDS
SEE DETAIL 3/A4.30 FOR
4
TYPICAL GUTTER SIZE
H.P.
12
LINE OF BUILDING
DS
DS
BELOW, TYP.
BELOW, TYP.
E-ROOF-01,BUILDINGS B1 & B2 - ENLARGED ROOF PLAN
L.P.
TYP.
4
H.P.
L.P.L.P.
L.P.L.P.
12
DS
BUILDINGS B1 & B2 - ROOF PLAN
DS
DS
DS
DS
4
DSDSDSDSDSDS
12
H.P.L.P.L.P.H.P.L.P.L.P.
H.P.H.P.
L.P.
4
TYP.
12
44
4
L.P.
1212
12
DS
DS
H.P.
H.P.
H.P.
L.P.
1/16"=1'-0"
4
12
DSDS
12
L.P.L.P.
1/4"=1'-0"
H.P.SCALE:
4
12
SCALE:
DSDS
DS
DS
DS
H.P.H.P.
L.P.
DSDS
L.P.
H.P.
L.P.
44
L.P.
1212
H.P.
L.P.L.P.
DSDS
H.P.
DSDS
DSDS
DSDSDS
DS
DS
L.P.L.P.
H.P.
L.P.L.P.
TYP.
TYP.
44
DS
DS
DS
1212H.P.H.P.
DS
L.P.
BLDG. B2
L.P.H.P.
DS
DS
H.P.
L.P.
L.P.
SEE DETAIL 3/A4.30 FORH.P.
44
BLDG. B1
TYPICAL GUTTER SIZE
1212
DS
LINE OF BUILDING
H.P.
44
BELOW, TYP.
1212
DS
TYP.DS
DS
TYP.L.P.
L.P.
BUILDINGS B1 & B2 - ENLARGED ROOF PLAN
H.P.
L.P.L.P.
DSDS
DS
DS
44
1212
DSDSDSDS
H.P.
L.P.
L.P.
44
1212
1/4"=1'-0"
SCALE:
SEE DETAIL 3/A4.30 FOR
TYPICAL GUTTER SIZE
DS
DS
LINE OF BUILDING
BELOW, TYP.
SEE DETAIL 15/A4.32
ROOF VENT, TYP.
H.P.
4
12
DS
H.P.
44
1212
TYP.
H.P.
TYP.
4
12
DS
DS
DS
CRICKET, TYP.
E-ROOF-01,
E-ROOF-01
TYP.
TYP.
L.P.L.P.
A2.30
Issued for Permit & Construction
ON EXPANSION JOINT LOCATIONS. REFER TO
REFERENCE ONLY AND TO BE PROVIDED BY
MILLWORK AT RECEPTION TO BE PROVIDED
SEE SHEET A3.30 FOR MORE INFORMATION
SEE SHEET A8.10 FOR WINDOW SCHEDULE
FURNITURE AND EQUIPMENT SHOWN FOR
Issued for Code Review
University of Iowa
SHEET A4.37 FOR PLAN DETAILS.
TYPE AND SIZE INFORMATION
DESCRIPTION
2013 Solomon Cordwell Buenz
ASI-002
ASI-001
08.01.201307.31.201306.07.201305.03.2013
BY OWNER.
DATE
OWNER.
NO.
2
1
1.2.3.4.
A3.50
2
CJ.
E-BRK-02,
TYP.
BUILDING C - ENLARGED FIRST FLOOR PLAN
TYP.
CJ.
PURPOSE
MULTI-
CJ.
SEE DETAIL
PARTITION
MOVABLE
1/4"=1'-0"
2/A6.60
SCALE:
SEE DETAIL 4/A4.36
CONCRETE BENCH
PANTRY
MULTI-PURPOSE
GAME ROOM
AT REVEAL SIDING
ABOVE DOORS
MULTI-PURPOSE
MECH. ROOM
SEE DETAIL 9/A1.30
STORAGE
DOOR OPERATOR
FEC
CJ.
SST-01
WORK POINT
DOOR OPERATORSEE DETAIL 9/A1.30
VESTIBULE
CORRIDOR
SEE DETAIL
WORK POINT CORRIDOR PARTITION;PARTITION;SEE DETAIL
VENDINGVENDING PARTITION;PARTITION;
ENTRY
ENTRY/ENTRY
ENTRY/
KNOX BOXKNOX BOX
MOVABLE
4/A6.604/A6.60
SST-01SST-01
CORRIDOR MOVABLEPARTITION;SEE DETAIL4/A6.60SST-01
FEC
FEC
FECFECFEC
VENDINGVENDING
N.I.C.N.I.C.
RECEPTION
DESK BY OWNER
CONCRETE BENCHSEE DETAIL 4/A4.36
MAIL ROOM/
PCKG
EQUIPMENT N.I.C.
OFFICE
EQUIPMENT N.I.C.
FITNESS
FITNESS
FITNESS
OFFICE
TYP.
RESTROOM
WOMEN'S
LAUNDRY
SIM.
WORK ROOM
RESTROOM
MEN'S
COIN OPERATED
WASHERS AND
DRYERS N.I.C.
MAINTENANCE
MECHANICAL
TYP.
LINE OF ROOFABOVEE-FCB-02,
FEC
FEC
A2.31
A3.10
Issued for Permit & Construction
BASED ON BUILDING A1 (FOR BUILDING A2
AND BUILDING A3 ACCESSIBLE WINDOW
SIDING TO BE E-PNT-01, UNLESS NOTED
3. ALL DOORS, ADJACENT SIDELITES, ANDABOVE FINISH FLOOR TO MEET SAFETYACCESSIBLE WINDOWS AS SHOWN ARE
1. ALL TRIM COLOR OF FIBER CEMENT TO
Issued for Code Review
ALL WINDOWS WITH SILLS BELOW 22"
LOCATIONS, REFER TO SHEET A0.40).
SIDING, UNLESS NOTED OTHERWISE.REFER TO MECHANICAL & PLUMBING
2. ALL FIELD COLOR OF FIBER CEMENT
University of Iowa
MATCH ADJACENT FIBER CEMENT
ELEV. +0'-0" = 663.00' - BLDG. 'A1'ELEV. +0'-0" = 662.50' - BLDG. 'A2'ELEV. +0'-0" = 662.00' - BLDG. 'A3'ELEV. +0'-0" = 663.00' - BLDG. 'B1'ELEV. +0'-0" = 663.00' - BLDG. 'B2'
ELEV. +0'-0" = 663.00' - BLDG. 'C'
DESCRIPTION
DRAWINGS FOR EQUIPMENT
GLAZING REQUIREMENTS.2013 Solomon Cordwell Buenz
INSTALLATION DETAILS.
ASI-006ASI-002
BUILDING DATUM
OTHERWISE.
10.18.201308.01.201306.07.201305.03.2013
DATE
NO.
2
1
4.5.
FIRST FLOOR
+0'-0"
B/ ROOF EAVEB/ ROOF EAVEB/ ROOF EAVE
THIRD FLOOREL:THIRD FLOORTHIRD FLOOR
+22'-1 1/4"+22'-1 1/4"+22'-1 1/4"
FIRST FLOORFIRST FLOOR
GAS METERS
+32'-6"+32'-6"+32'-6"
+0'-0"+0'-0"
EL:EL:EL:EL:EL:EL:EL:EL:
CJ
CJ
CJ
BUILDING TYPE 'A' - NORTH ELEVATION E-WIN-02E-WIN-01
BUILDING TYPE 'A' - SOUTH ELEVATION
BUILDING TYPE 'A' - EAST ELEVATION
CJ
CJ
CJ
CJ
CJCJ
1/8"=1'-0"1/8"=1'-0"1/8"=1'-0"
CJ
CJ
CJ
SCALE:SCALE:SCALE:
CJ
CJ
ELECTRIC METERS
ALUM. FRAME ENT.
LIGHT FIXTURE
CJ
CJ
SCHEDULED
E-BRK-01AE-ROOF-01E-FCB-04A
E-ROOF-01E-FCB-04AE-BRK-01AE-ROOF-01E-FCB-04A
E-FCB-01
E-FCB-01E-MTL-03E-BRK-01E-MTL-03E-FCB-04E-BRK-01AE-FCB-04A
E-MTL-03E-FCB-04E-BRK-01E-MTL-03E-VNT-01E-WIN-01
E-WIN-01E-VNT-01E-WIN-01
E-FCB-01
E-BRK-01
DOOR
TYP.TYP.
CJ
CJ
CJ
CJ
TYP.TYP.
CJ
CJ
CJ
CJ
CJ
LIGHT FIXTURE
BUILDING TYPE 'A' - WEST ELEVATION
SCHEDULED
CJ
SCHEDULED LIGHT FIXTURE
ALUM. FRAME ENT. DOOR
E-CANOPY-01
SIM. OH
SIM. OH
SIM. OHSIM. OH
CJ
INTERFACE WITH THE EXTERIOR BUILDING
MATERIALS AT THE HEAD, JAMB, SILL AND
CONTRACTOR TO PROVIDE AN IN-PLACE
MOCK-UP THAT CONTAINS AN EXAMPLE
SNOW GUARDS
OF THE WINDOW SYSTEMS AND
1/8"=1'-0"
BAY CORNER CONDITIONS
CJ
SCALE:
CJ
CJ
CJ
CJ
TYP.TYP.
CJ
LIGHT FIXTURE
E--CANOPY-01
GAS METERS
SCHEDULED
E-BRK-01A
E-ROOF-01
E-MTL-03E-FCB-04E-FCB-01
E-BRK-01
CJ
CJCJ
E-BRK-01A
E-FCB-04AE-ROOF-01
E-ROOF-01E-BRK-01A
E-MTL-03E-FCB-01E-FCB-04
E-BRK-01E-MTL-03
E-FCB-01E-VNT-01E-WIN-01
E-MTL-03E-FCB-04
E-VNT-01E-WIN-01E-BRK-01
TYP.TYP.
CJ
CJ
CJ
BUILDING TYPE 'A' - PARTIAL EAST ELEVATION
CJ
CJ
CJCJ
CJ
CJ
1/8"=1'-0"
CJ
CJ
SCALE:
E-WIN-02
E-WIN-01
CJ
CJ
CJ
SCHEDULEDLIGHT FIXTURE
A3.20
Issued for Permit & Construction
ACCESSIBLE WINDOW LOCATIONS, REFER
BASED ON BUILDING B2 (FOR BUILDING B1
SIDING TO BE E-PNT-01, UNLESS NOTED
3. ALL DOORS, ADJACENT SIDELITES, ANDABOVE FINISH FLOOR TO MEET SAFETYACCESSIBLE WINDOWS AS SHOWN ARE
1. ALL TRIM COLOR OF FIBER CEMENT TOORIENTATIONS HAVE BEEN REVISED IN
Issued for Code Review
ALL WINDOWS WITH SILLS BELOW 22"
SIDING, UNLESS NOTED OTHERWISE.REFER TO MECHANICAL & PLUMBING
2. ALL FIELD COLOR OF FIBER CEMENT
University of Iowa
MATCH ADJACENT FIBER CEMENT
ELEV. +0'-0" = 663.00' - BLDG. 'A1'ELEV. +0'-0" = 662.50' - BLDG. 'A2'ELEV. +0'-0" = 662.00' - BLDG. 'A3'ELEV. +0'-0" = 663.00' - BLDG. 'B1'ELEV. +0'-0" = 663.00' - BLDG. 'B2'
ALL 1/4 WINDOW COMBINATIONELEV. +0'-0" = 663.00' - BLDG. 'C'
ACCORDANCE WITH RFI-0019.
DESCRIPTION
DRAWINGS FOR EQUIPMENT
GLAZING REQUIREMENTS.2013 Solomon Cordwell Buenz
INSTALLATION DETAILS.
ASI-006ASI-002
ASI-001
BUILDING DATUM
TO SHEET A0.40).
OTHERWISE.
10.18.201308.01.201307.31.201306.07.201305.03.2013
DATE
NO.
32
1
4.5.6.
ALUM. FRAME ENT. DOOR
FIRST FLOOR
+0'-0"
LIGHT FIXTURE
E-CANOPY-01
GAS METERS
SNOW GUARD
B/ ROOF EAVEB/ ROOF EAVE
SCHEDULED
THIRD FLOORTHIRD FLOOREL:
+22'-1 1/4"+22'-1 1/4"
FIRST FLOOR
E-ROOF-01
E-FCB-04A
E-ROOF-01
E-FCB-04A
E-WIN-01
+32'-6"E-WIN-01E-FCB-01+32'-6"
E-MTL-03
E-WIN-01E-FCB-01+0'-0"
EL:EL:EL:EL:EL:
CJ
CJ
BUILDING TYPE 'B' - 'B2' NORTH ELEVATION
BUILDING TYPE 'B' - 'B1' NORTH ELEVATION
BUILDING TYPE 'B' - 'B1' SOUTH ELEVATIONBUILDING TYPE 'B' - 'B2' SOUTH ELEVATION
CJ
BUILDING TYPE 'B' - 'B2' WEST ELEVATIONBUILDING TYPE 'B' - 'B1' WEST ELEVATION
BUILDING TYPE 'B' - 'B1' EAST ELEVATIONBUILDING TYPE 'B' - 'B2' EAST ELEVATION
CJ
CJ
CJ
CJ
BUILDING TYPE 'B' - 'B1' NORTH ELEVATION
CJ
TYP.
1/8"=1'-0"1/8"=1'-0"1/8"=1'-0"1/8"=1'-0"
CJ
CJ
CJ
CJ
SCALE:SCALE:SCALE:SCALE:
TYP.
CJ
CJCJ
CJ
E-BRK-01A
E-BRK-01AE-ROOF-01
E-ROOF-01
E-BRK-01
E-FCB-01
E-BRK-01E-MTL-03
E-FCB-01E-MTL-03E-WIN-01E-WIN-01
E-WIN-01
E-ROOF-01E-BRK-01A
E-FCB-01E-MTL-03E-WIN-02
E-BRK-01E-VNT-01
E-WIN-01
CJ
E-WIN-02
E-VNT-01E-WIN-01
CJ
CJ
ELECTRIC METERS
CJ
TYP.TYP.
CJ
CJ
CJ
CJ
LIGHT FIXTURE
TYP.TYP.
SCHEDULED
E-VNT-01
CJ
CJ
LIGHT FIXTURE
SCHEDULED
TYP.TYP.
CJ
CJ
CJ
CJ
TYP.TYP.
TYP.TYP.
CJ
CJ
CJ
TYP.TYP.
CJ
CJ
LIGHT FIXTURE
SCHEDULED
E-VNT-01
CJ
CJ
CJ
LIGHT FIXTURE
E-ROOF-01
GAS METERSE-FCB-01
ALUM. FRAMEE-MTL-03
SCHEDULEDE-WIN-01
E-FCB-04A
E-ROOF-01
E-BRK-01AENT. DOOR
E-FCB-04A
E-BRK-01A
E-FCB-04AE-ROOF-01CJ
E-MTL-03E-WIN-01E-MTL-03
E-FCB-01E-BRK-01
E-MTL-03E-MTL-03E-FCB-01
E-BRK-01
E-WIN-01
E-BRK-01AE-BRK-04AE-ROOF-01
E-BRK-01AE-FCB-04A
E-FCB-01E-MTL-03
E-BRK-01E-WIN-01
E-BRK-01
B/ ROOF EAVE
THIRD FLOOR
+22'-1 1/4"FIRST FLOOR
BUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - NORTH
BUILDING TYPE 'B' - 'B2' PARTIAL ELEVATION - SOUTH
+32'-6"
BUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WEST+0'-0"
BUILDING TYPE 'B' - 'B2' PARTIAL ELEVATION - EAST
EL:EL:EL:
CJ
SNOW GUARD
CJ
LIGHT FIXTURELIGHT FIXTURE
E-CANOPY-01
CJ
SCHEDULED
BUILDING TYPE 'B' - 'B2' PARTIAL ELEVATION - EAST
CJ
SNOW GUARD
BUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION
- WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING
TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION -
WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING
TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION -
WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING
TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION -
WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING
TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION -
WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WEST
BUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION
- WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING
TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION -
WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING
TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION -
WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING
TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION -
WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING
TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION -
WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING
TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WEST
BUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WEST
BUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WEST
BUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WEST
SCHEDULED LIGHT FIXTURE
CJALUM. FRAME ENT. DOOR
E-CANOPY-01
CJ
BUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WEST
BUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WEST
BUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WEST
BUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION
- WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING
TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION -
WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WEST
BUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION
- WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING
TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION -
WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING
TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION -
WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING
TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION -
WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL
ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' -
'B1' PARTIAL ELEVATION - WESTBUILDING TYPE 'B' - 'B1' PARTIAL ELEVATION - WEST
1/8"=1'-0"1/8"=1'-0"
CJ
SCALE:SCALE:
CJE-WIN-02
E-WIN-01
CJ
CJ
A3.40
m
A3.50
A4.10
A4.11
A4.20
A4.30
FIELD PRIME EDGES OF ALL SIDING PANELS CUT
Issued for Permit & Construction
REFER TO DETAILS 1-3 ON SHEET A8.05 FOR
REFER TO STRUCTURAL SHEET S6.00 FOR
MAINTAIN 2" BETWEEN GRADE AND BRICK
SEE A0.20 FOR FULL FINISHES SCHEDULE
TYPICAL FLOOR / CEILING ASSEMBLIES.
Issued for Code Review
University of Iowa 2013 Solomon Cordwell Buenz
TYPICAL ROOF FRAMING DETAILS.
DESCRIPTION
ASI-004
LEDGE, TYPICAL.
09.04.201306.07.201305.03.2013
DATE
IN FIELD.
NO.
1
2.3.4.5.
1.
2X6 WOOD STUD
WINDOW STOOL
CONT. SEALANT
PAINTED WD-02
FRAMING, SEESTRUC. DWGS
E-INSUL-02E-INSUL-04E-INSUL-02
E-WIN-01
TYP.
TYP.
EXTERIOR WALL DETAILEXTERIOR WALL DETAILEXTERIOR WALL DETAIL
3" = 1'-0"3" = 1'-0"3" = 1'-0"
FASCIA FASTENER IN BED OFROOF DOWN FASCIA & WRAPBOARD PERFORATED SOFFIT
E-WP-04 TO EXTEND FROM
FOUNDATION INSULATION
(EXTEND TO BOTTOM OF
E-FCB-06 FIBER CEMENT
E-INSUL-01 PERIMETER
CONC. SPLASH BLOCK
E-WP-04 STRIP OVERUNDER SOFFIT EDGE
SCALE:SCALE:SCALE:
E-ROOF-01 ASPHALT
SHINGLES ON ROOF
FOUNDATION WALL)
FASCIA DRIP EDGE
UNDERLAYMENTFIRST FLOOR
+0'-0"
SEALANT
E-SH-02
EL:
FASCIA FASTENER IN
BED OF SEALANT
E-INSUL-02
EXTERIOR FIRE RATED WALL CONSTRUCTION
EXTERIOR WALL DETAILEXTERIOR WALL DETAIL
NAILED TO STUDS AND BEARING PLATES 7"O.C. WITH 6d CEMENT COATED NAILS. FOR
PANELS, MIN. GRADE 'C-D' OR 'SHEATHING'
PER UL DESIGN #U356, AT INTERIOR FACE,
PROVIDE ANY CLASSIFIED 5/8" THICK 4 FT.
WIDE GYP. BD. APPLIED VERTICALLY ANDATTACHED TO STUDS ON EXTERIOR SIDE
STUDS. VERTICAL JOINTS CENTERED ON
PARALLEL WITH OR PERPENDICULAR TONAILS SPACED 6" O.C. AT PERIMETER OF
OF WALL WITH 6d CEMENT COATED BOX
THICK, 4 FT. WIDE WOOD STRUCTURALWITH NO. 2x4 WOOD BLOCKING. TO BE
PANELS AND 12" O.C. ALONG INTERIORAT EXTERIOR FACING, PROVIDE BRICK
INSTALLED WITH LONG DIMENSION OFSTUDS. HORIZONTAL JOINTS BACKED
SHEET OR FACE GRAIN OF PLYWOOD
EXTERIOR FACE, PROVIDE 7/16" MIN.
VENEER OR FIBER CEMENT SIDING.
3" = 1'-0"3" = 1'-0"3" = 1'-0"
E-WP-04 STRIP OVER CONTIN.
BOARD PERFORATED SOFFIT
ROOF DOWN FASCIA & WRAP
E-WP-04 TO EXTEND FROM
E-FCB-06 FIBER CEMENT
E-SL-01 CONTINUOUS
UNDER SOFFIT EDGE
SCALE:SCALE:SCALE:
FASCIA DRIP EDGE
FIRST FLOOR
+0'-0"
SEALANT
STUDS.
EL:
EXTERIOR WALL DETAIL
3" = 1'-0"
E-WP-04 STRIP OVER CONTIN.
SCALE:
FASCIA DRIP EDGE
FIRST FLOOR
+0'-0"
EL:
A4.31
A4.32
C.J.
C.J.
A4.35
REF ARCH
A4.37
A5.10
LANDING WIDTH
3'-8" CLEAR
WORK LINE
NOSING LINE
A6.01
A6.10
A6.20
USED IN MULTI-PURPOSE ROOMUSED IN MULTI-PURPOSE ROOMUSED IN MULTI-PURPOSE ROOM
USED IN WORK ROOMUSED IN WORK ROOM
REMARKS
OVERALL OPENING W/
HEIGHT
--------
CLEARANCES
WIDTH
--------
HEIGHT
"
"
"
"""
"
ACTUAL SIZE (INCHES)
673266
161216
5
DEPTH
"""
"""
24"
312130
1515
5
WIDTH
""
""
"
24"33"
33292929
5
STAINLESS STEELSTAINLESS STEELSTAINLESS STEELSTAINLESS STEEL
WHITEWHITE
FINISH
N/A
JNM1541DMWW
JVM1540LMSSGTH18DBDWW
GLDA696PSS
GECR3321
GFC325V
MODEL
TBD
-
MANUFACTURER
ELKAY
GEGEGEGEGEGE
REFRIGERATOR, 21.9 CU. FT. ; SIDE BY SIDE
REFRIGERATOR, 18.0 CU. FT.
MICROWAVE, 1.5 CU. FT.MICROWAVE, 1.5 CU. FT.
GARBAGE DISPOSAL
DESCRIPTION
DISHWASHER
BAR SINK
TAG
ABDEFH
CG
SEE 1/A6.60 FOR MORE
MOVABLE PARTITION
TELEVISION N.I.C.
INFORMATION
A6.21
REMARKS
STAINLESS STEELSTAINLESS STEELSTAINLESS STEEL
FINISH
SATIN
MODEL 5402
MODEL 234
TOILET TISSUE
MODEL
DISPENSER
GRAB BAR
6542
812
DB
MANUFACTURER
BRADLEYBRADLEYBRADLEYBRADLEY
TOILET TISSUE
DISPENSER
GRAB BAR
TOWEL DISPENSER / WASTE RECEPTACLE
DB
TOILET TISSUE DISPENSER
SOAP DISPENSER
DESCRIPTION
GRAB BAR
TAG
ABCDE
CABINET; SEE A0.41 FOR
MOVEABLE PARTITION
MOUNTING HEIGHTS
FIRE EXTINGUISHER
SOAP DISPENSER
SST-01
PNT-01
TOILET TISSUE
C
DISPENSER
PCT-01
B
SOAP DISPENSER
BEYOND
OPEN
TO
C
GRAB BAR
D
WD-01, PNT-01
TOWEL DISPENSER /WASTE RECEPTACLE
SEMI-RECESSED
SST-01
A
BEYOND
OPEN
TO
PCT-01
TELEVISION, N.I.C.
PNT-01
SST-01
BEYOND
OPEN
TO
TOWEL DISPENSER /WASTE RECEPTACLE
MAINTAIN 2 HR FIRE
RATED ASSEMBLY
SEMI-RECESSED
A
TOILET TISSUE
DISPENSER
GRAB BAR
DB
PCT-01
PNT-02SST-01
A6.22
SST-01
20 MAILBOXES
PHASE 1
20 MAILBOXES
PHASE 1
20 MAILBOXES
PHASE 1
20 MAILBOXES
PHASE 1
PHASE 1
TRASH
9 MAILBOXES
PHASE 2
20 MAILBOXES
PHASE 2
CONCRETE PAD
DRYER, N.I.C.
20 MAILBOXES
PHASE 2
20 MAILBOXES
PHASE 2
20 MAILBOXES
PHASE 1
20 MAILBOXES
PHASE 1
MAILBOXES AT PHASE 2
INSTALLATION OF
DRYWALL TO BE
CONSTRUCTION
REMOVED FOR
20 MAILBOXES
PHASE 1
20 MAILBOXES
PHASE 1
20 MAILBOXES
PHASE 1
20 MAILBOXES
PHASE 2
20 MAILBOXES
PHASE 1
20 MAILBOXES
PHASE 2
20 MAILBOXES
PHASE 2
CONCRETE PAD
WASHER
N.I.C.
20 MAILBOXES
PHASE 2
PHASE 2
TRASH
PHASE 1
TRASH
20 MAILBOXES
PHASE 1
SST-01
MAILBOXES AT PHASE 2
INSTALLATION OF
DRYWALL TO BE
CONSTRUCTION
REMOVED FOR
20 MAILBOXES
PHASE 1
20 MAILBOXES
PHASE 1
20 MAILBOXES
PHASE 2
20 MAILBOXES
PHASE 1
20 MAILBOXES
PHASE 2
WASHER, N.I.C.CONCRETE PAD
DRYER, N.I.C
20 MAILBOXES
PHASE 2
20 MAILBOXES
PHASE 2
20 MAILBOXES
PHASE 2
MAILBOXES AT PHASE 2
INSTALLATION OF
DRYWALL TO BE
CONSTRUCTION
REMOVED FOR
A6.40
SEE A0.40 AND A0.41 FOR ACCESS COMPLIANCE
Issued for Permit & Construction
Issued for Code Review
University of Iowa
DESCRIPTION
INFO AND UNIT LOCATIONS
2013 Solomon Cordwell Buenz
ASI-007
10.21.201306.07.201305.03.2013
DATE
NO.
1
1.
1 BED 1 BATH - ACCESSIBLE PLAN
1 BED 1 BATH - BATH 01 PLAN
DOORS ARE NOT PROVIDEDWASHER AND DRYER TO BE
SHELF WITH ROD AT 48"
AT WASHER/DRYER INPROVIDED BY OWNER
ACCESSIBLE UNIT
A.F.F.
1/2"=1'-0"
1/2"=1'-0"
SCALE:
SCALE:
1 BED 1 BATH - KITCHEN PLAN
1/2"=1'-0"
1 BED 1 BATH - BATH 01 ELEV.
SCALE:
PLM-51
1/2"=1'-0"
PLM-52; COUNTERTOP
SCALE:
LAVATORY AND
& BACKSPLASH
WD-51, PNT-51
MIRROR
FAUCET
PNT-51
TYPE B UNITS; NON-VENTED STANDARD RANGE HOOD
TYP.
1 BED 1 BATH - KITCHEN ELEV.
ACCESSIBLE UNITS; UPFRONT CONTROLS
ACCESSIBLE UNITS; WALL SWITCH
TYPE B AND ACCESSIBLE UNITSTYPE B AND ACCESSIBLE UNITSTYPE B AND ACCESSIBLE UNITS
MIRROR
EXCLUDING UNIT 109EXCLUDING UNIT 109EXCLUDING UNIT 109
L
CC
CCCL
TYPE B UNITS
REMARKSREMARKS
1 BED 1 BATH - BATH 01 ELEV.
1/2"=1'-0"
POLISHED ALUMINUM
POLISHED ALUMINUM
STAINLESS STEEL
OVERALL OPENING W/
HEIGHT
POLYSTYRENE
SATIN NICKELSATIN NICKEL
SCALE:
WALL SWITCH FOR
-------
CLEARANCES
REFRIGERATOR
WHITE
FINISH
RANGE HOODRANGE HOOD
CAB-51-ACC
WIDTH
RANGE
PNT-51
-------
AAGG
D
HEIGHTHEIGHT
"
"
""
"
"
ACTUAL SIZE (INCHES)
66 46 32 46
12
600 SERIES600 SERIES
5
MODEL
DEPTHDEPTH
SH-411
51412
"
""
""
9400
812
24"
1/2"=1'-0"
30 25 26
17
5
WIDTHWIDTH
ACCESS-ABLE DESIGNS
"""
"
"
24"
29 29 29 29
SCALE:
5
AMERICAN PRIDE
MANUFACTURER
REINFORCING FOR
GRAB BARS, TYP.
WD-51, PNT-51
GRAB BARS
DELANEYDELANEYBRADLEY
HARNEY
PNT-51
C
D
FEWHITEWHITEWHITEWHITEWHITE
FINISH
N/A
-
1 BED 1 BATH - KITCHEN ELEV.
GTH18DBDWW
GLDA690PWW
TOILET TISSUE HOLDER - SURFACE
JBP35DDWW
JBS15MWW
JN327HWW
GFC325V
SWING DOWN SHOWER SEAT
MODEL
-
SHOWER ROD- 5 FEET
TOWEL BAR - 24 INCH
MEDICINE CABINETS
PLM-52; COUNTERTOP
MEDICINE CABINET
MEDICINE CABINETPLM-52; COUNTERTOP
DESCRIPTION
MANUFACTURER
& BACKSPLASHLAVATORY AND
GRAB BAR
1 BED 1 BATH - BATH 01 ELEV.
MIRROR
FAUCET
C
GEGEGEGEGEGE TAG
-
1/2"=1'-0"
SCALE:
DISHWASHER
CAB-51-ACC
REFRIGERATOR, 18.0 CU. FT.
PLM-51
PNT-51
RANGE, 30", 5.3 CU. FT.RANGE, 30", 5.3 CU. FT.
GARBAGE DISPOSAL
C
1/2"=1'-0"
DESCRIPTION DISHWASHERRANGE HOODRANGE HOOD
SCALE:
REINFORCING FOR
GRAB BARS, TYP.
TOILET PAPER
TAG
WD-51, PNT-51
AABDE
CFG
TOWEL BAR
GRAB BAR
HOLDER
A
EB
CAB-51PLM-51
A
1 BED 1 BATH - KITCHEN ELEV.
1 BED 1 BATH - BATH 01 ELEV.
1/2"=1'-0"
SCALE:
WD-51, PNT-51
1/2"=1'-0"
PNT-52
PNT-51
SCALE:
REINFORCING FOR
GRAB BARS, TYP.
TOILET PAPERWD-51, PNT-51
GRAB BAR
HOLDER
PNT-51
TYP.
A
E
A6.42
SEE A0.40 AND A0.41 FOR ACCESS COMPLIANCE
Issued for Permit & Construction
Issued for Code Review
University of Iowa
DESCRIPTION
INFO AND UNIT LOCATIONS
2013 Solomon Cordwell Buenz
ASI-007
10.21.201306.07.201305.03.2013
DATE
NO.
1
1.
2 BED 2 BATH - ACCESSIBLE PLAN
2B/2B - BATH 01 PLAN
1/2"=1'-0"
1/2"=1'-0"
SCALE:
SCALE:
WASHER AND DRYER TO BE
2B/2B - KITCHEN PLAN
PROVIDED BY OWNER
SHELF WITH ROD AT 48"
A.F.F.
1/2"=1'-0"
SHELF WITH ROD AT 48"
SCALE:
2B/2B - BATH 01 ELEV.
A.F.F.
SHELF WITH ROD
WD-51, PNT-51
AT 48" A.F.F.
SHELF WITH RODAT 48" A.F.F.
1/2"=1'-0"
SCALE:
REINFORCING FOR
GRAB BARS, TYP.
TOILET PAPER
WD-51, PNT-51
PNT-52 GRAB BARS
PNT-51TOWER BAR
HOLDER
PNT-51
A
BE
2B/2B - KITCHEN ELEV.
PLM-52; COUNTERTOP
PLM-52; COUNTERTOP
TYP.
& BACKSPLASHLAVATORY AND
MIRROR
FAUCET
2B/2B - BATH 01 ELEV.
1/2"=1'-0"
SCALE:
WALL SWITCH FOR
TYP.
REFRIGERATOR
RANGE HOOD
CAB-51-ACC
RANGE
PNT-51PLM-51
HOOD
1/2"=1'-0"
AA
D
B
SCALE:
REINFORCING FOR
SHOWER CURTAIN
GRAB BARS, TYP.
TYPE B UNITS; NON-VENTED STANDARD RANGE HOOD
TOILET PAPER
WD-51, PNT-51
GRAB BARS
HOLDER
PNT-51
PLM-51
ROD
ACCESSIBLE UNITS; UPFRONT CONTROLS
A
D
E
ACCESSIBLE UNITS; WALL SWITCH
TYPE B AND ACCESSIBLE UNITSTYPE B AND ACCESSIBLE UNITSTYPE B AND ACCESSIBLE UNITS
EXCLUDING UNIT 106EXCLUDING UNIT 106EXCLUDING UNIT 106
MIRROR
TYPE B UNITS
REMARKSREMARKS
L
CC
CCCL
POLISHED ALUMINUM
STAINLESS STEEL
2B/2B - KITCHEN ELEV.
OVERALL OPENING W/
HEIGHT
POLYSTYRENE
SATIN NICKELSATIN NICKEL
-------
CLEARANCES
FINISH WHITE
WIDTH
2B/2B - BATH 01 ELEV.
-------
HEIGHTHEIGHT
"
"
""
"
"
ACTUAL SIZE (INCHES)
46 46
66 32 12
600 SERIES600 SERIES
5
1/2"=1'-0"
MODEL
DEPTHDEPTHSH-411
51412
"
""
""
9400
812
24"
30 25 26
17
5
SCALE:
WIDTHWIDTHACCESS-ABLE DESIGNS
"""
"
"
24"
29 29 29 29
1/2"=1'-0"
5
DISHWASHERAMERICAN PRIDE
MANUFACTURER
CAB-51-ACC
PNT-51
DELANEYDELANEYBRADLEY
SCALE:HARNEY
REINFORCING FOR
SHOWER CURTAIN
C
GRAB BARS, TYP.
WD-51, PNT-51
WHITEWHITEWHITEWHITEWHITE
FINISH
GRAB BARS
N/A
PNT-51-
ROD
D
E
GTH18DBDWW
GLDA690PWW
TOILET TISSUE HOLDER - SURFACE
JBP35DDWW
JBS15MWW
JN327HWW
GFC325V
SWING DOWN SHOWER SEAT
MODEL
-
SHOWER ROD- 5 FEET
TOWEL BAR - 24 INCH
MEDICINE CABINETS
2B/2B - KITCHEN ELEV.
DESCRIPTION
MANUFACTURER
GRAB BAR
GEGEGEGEGEGE TAG
-
1/2"=1'-0"
2B/2B - BATH 01 ELEV.
SCALE:
REFRIGERATOR, 18.0 CU. FT.
CAB-51-ACC
RANGE, 30", 5.3 CU. FT.RANGE, 30", 5.3 CU. FT.
GARBAGE DISPOSAL
PNT-51PLM-51
DESCRIPTION DISHWASHERRANGE HOODRANGE HOOD
1/2"=1'-0"
TAG
ABCDEFG
PLM-52;COUNTERTOP
SCALE:
MEDICINE CABINET
LAVATORY AND
& BACKSPLASH
WD-51, PNT-51
MIRROR
FAUCET
PNT-51
TYP.
C
A6.60
Issued for Permit & Construction
Issued for Code Review
University of Iowa
DESCRIPTION
2013 Solomon Cordwell Buenz
ASI-002
08.01.201306.07.201305.03.2013
DATE
NO.
1
OPERABLE PARTITION PLAN - MULTI-PURPOSE ROOM
OPERABLE PARTITION ELEV. - MULTI-PURPOSE ROOM
SIM.
SIM.
OPERABLE PARTITION ELEV. - ENTRY
OPERABLE PARTITION PLAN - ENTRY
3/8" = 1'-0"
SIM.
3/8" = 1'-0"3/8" = 1'-0"3/8" = 1'-0"
SCALE:
NOTE: DIMENSIONS AREPARTITION PANEL SIZESNOTE: DIMENSIONS AREPARTITION PANEL SIZES
TO BE COORDINATED INTO BE COORDINATED IN
REFERENCE ONLY ANDREFERENCE ONLY AND
SCALE:THE FIELD AND WITHSCALE:THE FIELD AND WITHSCALE:
COORDINATED WITHCOORDINATED WITH
FOLDING PARTITIONFOLDING PARTITION
NOTE: FOLDABLENOTE: FOLDABLE
INDICATED FORINDICATED FOR
SUBMITTALSUBMITTAL
SHALL BESHALL BE
VENDORVENDOR
DETAIL AT OPERABLE WALL SECTION - MULTI-PURPOSE ROOM
REFER TO PARTITIONREFER TO PARTITIONREFER TO PARTITION
NOTE: DETAIL IS FORNOTE: DETAIL IS FORNOTE: DETAIL IS FOR
DETAIL AT EXPANDABLE PANEL WITH BULB SEAL JAMB
REFERENCE ONLY.REFERENCE ONLY.REFERENCE ONLY.
DOCUMENTS FORDOCUMENTS FORDOCUMENTS FOR
CRANK OPERATED BOTTOM SEAL
INSTALLATIONINSTALLATIONINSTALLATION
INFORMATIONINFORMATIONINFORMATION
ADDITIONALADDITIONALADDITIONAL
CLEARANCE (+.50" / -1.50")
PRE-PAINTED OFF WHITEPROVIDES 2" OPERATING
DROPPED SOFFIT TRIM
HANGER BRACKET#17 TRACK, STEEL,
GYP. BD. CEILING
BY MODERNFOLD
VINYL TOP SEAL
POLYMER DISK
HANGER RODS
2X4 FRAMING2X6 FRAMING
2X8 HEADER
2X4 KICKER
VINYL BULB SEAL
DETAIL AT BULB SEAL JAMB
BRACKET
GAGE
5.75"4.50"
BRACKET
5.75"5.75"5.75"4.50"
BRACKET
DETAIL AT PANEL JOINT
VINYL BULB SEAL
0" - 5.75"
TRAVEL
WRAPPED WITH MATERIAL
EXPANDABLE PANEL NOSE
3" = 1'-0"3" = 1'-0"3" = 1'-0"3" = 1'-0"
FINISHEDFINISHED
SOFFITFLOOR
SCALE:SCALE:SCALE:SCALE:
SUSPENDED A.C.T. CEILING
CRANK OPERATED BOTTOM SEAL
CLEARANCE (+.50" / -1.50")
PRE-PAINTED OFF WHITEPROVIDES 2" OPERATING
DROPPED SOFFIT TRIM
CEILING ASSEMBLY
CEILING ASSEMBLY
HANGER BRACKET#17 TRACK, STEEL,
BY MODERNFOLD
VINYL TOP SEAL
RATED GYP. BD.
POLYMER DISK
HANGER RODS
2X4 FRAMING2X6 FRAMING
2X8 HEADER
2X4 KICKER
DETAIL AT OPERABLE WALL SECTION - ENTRY
BRACKET
TRACK
GAGE
5.75"4.50"4.25"
5.75"BRACKET4.50"GAGE
CJT
.75"
SUSPENDED GYP. BD. CEILING
3" = 1'-0"
SCALE:
FINISHEDFINISHED
CEILING
FLOOR
A7.10
PAINT COLOR FOR GYPSUM BOARD CEILINGS AT
Issued for Permit & Construction
ACOUSTICAL CEILING TILE SUSPENDEDFIRE RATED FLOOR/CEILING ASSEMBLY
UNDERSIDE OF THE STAIR STRINGERS
REFER TO SHEET E5.00 FOR LIGHT FIXTURE
UNIT ENTRIES IN CORRIDORS TO BE PNT-02
PAINTED GYPSUM DRYWALL CEILING,
HORIZONTAL SHAFTWALL ASSEMBLY
PAINTED GYPSUM DRYWALL CEILING
BELOW THE GYPSUM BOARD OF THEBELOW THE GYPSUM BOARD OF THE
PAINTED GYPSUM DRYWALL AT THE
SUSPENDED BELOW THE GYPSUM
FOR FIRE RATED FLOOR/CEILING
Issued for Code Review
University of Iowa
FIRE RATED FLOOR/CEILING
BOARD OF THE FIRE RATED
FLOOR/CEILING ASSEMBLY
DESCRIPTION
2013 Solomon Cordwell Buenz
ASI-002
AND LANDINGS
ASSEMBLYASSEMBLY
08.01.201306.07.201305.03.2013
SCHEDULE.
DATE
LEGEND:
U.N.O.
NO.
1
2.3.
1.
PNT-01
CJ
BUILDINGS A1, A2, & A3 - FIRST FLOOR R.C.P.
BUILDINGS A1, A2, & A3 - TYPICAL FLOOR R.C.P.
1/8"=1'-0"
1/8"=1'-0"
SCALE:
SCALE:
CJPNT-01
A7.20
PAINT COLOR FOR GYPSUM BOARD CEILINGS AT
Issued for Permit & Construction
ACOUSTICAL CEILING TILE SUSPENDEDFIRE RATED FLOOR/CEILING ASSEMBLY
UNDERSIDE OF THE STAIR STRINGERS
REFER TO SHEET E5.00 FOR LIGHT FIXTURE
UNIT ENTRIES IN CORRIDORS TO BE PNT-02
PAINTED GYPSUM DRYWALL CEILING,
HORIZONTAL SHAFTWALL ASSEMBLY
PAINTED GYPSUM DRYWALL CEILING
BELOW THE GYPSUM BOARD OF THEBELOW THE GYPSUM BOARD OF THE
PAINTED GYPSUM DRYWALL AT THE
SUSPENDED BELOW THE GYPSUM
FOR FIRE RATED FLOOR/CEILING
Issued for Code Review
University of Iowa
FIRE RATED FLOOR/CEILING
BOARD OF THE FIRE RATED
FLOOR/CEILING ASSEMBLY
DESCRIPTION
2013 Solomon Cordwell Buenz
ASI-002
AND LANDINGS
ASSEMBLYASSEMBLY
08.01.201306.07.201305.03.2013
SCHEDULE.
DATE
LEGEND:
U.N.O.
NO.
1
2.3.
1.
9'-0"
9'-0"9'-0"
BLDG. B2
BLDG. B1
BUILDINGS B1 & B2 - FIRST FLOOR R.C.P.
8'-4"
8'-4"
8'-4"
VARIESVARIES
VARIES
VARIES
VARIES
VARIES
VARIES
8'-4"VARIES
VARIES
VARIES
VARIES
VARIES
VARIES
VARIES
VARIES
VARIES
VARIES
VARIES
7'-0"
VARIES
8'-4"
8'-4"
10'-1"
UNIT 116
9'-0"9'-0"
1/8"=1'-0"
9'-0"
SCALE:
8'-4"
8'-4"
VARIES
VARIES
VARIES
VARIES
VARIES
VARIES
A7.21
F6F6
F6F6
F6
F6
F6
A7.30
Issued for Permit & Construction
ACOUSTICAL CEILING TILE SUSPENDED
AT UNDERSIDE OF SLOPED TRUSS FOR
REFER TO SHEET E5.00 FOR LIGHT FIXTURE
PAINTED GYPSUM DRYWALL CEILING,
PAINTED GYPSUM DRYWALL CEILING
BELOW THE GYPSUM BOARD OF THE
BOARD OF THE FIRE RATED CEILING
SUSPENDED BELOW THE GYPSUM
FIRE RATED CEILING ASSEMBLY Issued for Code Review
FIRE RATED CEILING ASSEMBLY.
University of Iowa
CEILING HEIGHT VARIES.
DESCRIPTION
2013 Solomon Cordwell Buenz
ASI-002
ASSEMBLY
08.01.201306.07.201305.03.2013
SCHEDULE.
DATE
LEGEND:
NO.
1
2.
1.
BUILDING C - FIRST FLOOR R.C.P.
SEE MECHANICAL DWGSFOR EXPOSEDDUCTWORK
1/4"=1'-0"
SCALE:
LINE OF OVERHEAD
DOOR BELOW
A8.01
A8.05
INSTALLED WITH SETTING MORTAR ON TOP OF Issued for Permit & Construction
ALL TUB / SHOWER ENCLOSURES TO BE
Issued for Code Review
University of Iowa
DESCRIPTION
2013 Solomon Cordwell Buenz
ASI-007ASI-002
10.21.201308.01.201306.07.201305.03.2013
GYPCRETE.
DATE
NO.
2
1
1.
CONTINUOUS ACOUSTICAL
" T & G OSB WOOD PANEL (GLUED & NAILED)" T & G OSB WOOD PANEL (GLUED & NAILED)
-5 mm VINYL WOOD FLOORING (FLOOR FOLIO
" 25-GA. (RC-1) RESILIENT CHANNELS @ 16"" 25-GA. (RC-1) RESILIENT CHANNELS @ 24"
-3 1/2" (R-13) FIBERGLASS BATT INSULATION-3 1/2" (R-13) FIBERGLASS BATT INSULATION
WOOD BLOCKING
SLIT TAPE JOINT
GYPSUM BOARD
6" WOOD STUDLVT (2 MM WEAR / 3 MM CRUMB RUBBER)
PANELS -3/4" FLOOR TOPPING MIXTURE WITH UL
-SUBFLOORING MIN 15/32" THICK WOOD STRUC.
-RESILIENT CHANNELS OF 25 MSG THICK GALV
" LIGHTWEIGHT GYPCRETE TOPPING" LIGHTWEIGHT GYPCRETE TOPPING
5/8" TYPE 'X'
-14" OPEN WEB WOOD FLOOR TRUSS-14" OPEN WEB WOOD FLOOR TRUSS
@ 16" O.C.
SEALANT
TYPICAL
O.C. - PERPENDICULAR TO JOISTS
GLASS FIBER OR MINERAL WOOD WITH UL
-GYP BOARD NOM 5/8" THICK, 48" WIDE
-RESILIENT CHANNELS MIN
NOM 15/32" WOOD STRUC.
-ROOFING SYSTEM OVER-CHORD WOOD TRUSSES
-LOOSE FILL MATERIAL
-CARPET W/ OUT PAD
-UL DESIGN NO. P533-2X10 WOOD JOISTS 16" O.C." TYPE 'C' GYP. BD." TYPE 'C' GYP. BD.
CLASSIFICATION MARKING
-5/8" GYP. BOARD
-1X3 CROSS BRIDGING
PANELS
O.C.
UNIT
3/8"
MARKING
--------
STEEL
CORRIDOR WALL / CEILING ASSEMBLY
1 HR. FLOOR/CEILING ASSEMBLY IN UNITS1 HR. FLOOR/CEILING ASSEMBLY IN UNITS
ROOF / CEILING ASSEMBLY
CORRIDOR
3" = 1'-0"
1 1/2" = 1'-0"1 1/2" = 1'-0"
1 1/2" = 1'-0"
SCALE:
CONTINUOUS ACOUSTICAL
SUSPENDED ACOUSTICAL
1/2" RESILIENT CHANNELS1/2" RESILIENT CHANNELS
TYP. FLOOR ASSEMBLY -
CONTINUOUS WD. SILL
CEILING GRID SYSTEM
SOUND ATTENUATION
14" OPEN-WEB WOOD
5/8" TYPE 'X' GYPSUM5/8" TYPE 'X' GYPSUMSTEP/SHADOW EDGE5/8" TYPE 'X' GYPSUM
SCALE:SCALE:
SCALE:
MOLDING TO MATCH
UNDERSIDE OF OSBR-13 SOUND ATTEN.
BOARD, WRAP GYP.
TRUSS AND TRUSS
SEE DTL 1&2/A8.05.
2 x 8 FLOOR JOIST
BATT INSULATIONBATT INSULATION
DRAFTSTOPPING
CEILING SYSTEM
BD. & CONTINUE
VERTICALLY TO
SUBFLOOR TO
BLOCKS, TYP.
MAINTAIN
SEALANT
UL# L569
BOARDBOARD
PLATE
SECTION
TUB DETAIL @ CORRIDOR PARTITION
TUB DETAIL @ CORRIDOR PARTITION
PLAN
UNITUNIT
TUB DETAIL @ DEMISING PARTITIONTUB DETAIL @ DEMISING PARTITIONTUB DETAIL @ DEMISING PARTITION
TUB DETAIL @ DEMISING PARTITION
TUB DETAIL @ FURRED PARTITION
TUB DETAIL @ FURRED PARTITION
TUB DETAIL @ FURRED PARTITION
UNFINISHED SPACEUNFINISHED SPACE
TUB DETAIL @ WALL PARTITION
CORRIDORCORRIDOR
SECTION
SECTION
SECTION
PLAN
PLANPLAN
UNITUNIT
UNITUNITUNITUNIT
SEE WALL PARTITION TYPES FORSEE WALL PARTITION TYPES FORSEE WALL PARTITION TYPES FORSEE WALL PARTITION TYPES FOR
3" = 1'-0"3" = 1'-0"3" = 1'-0"3" = 1'-0"
5/8" TYPE 'X' GYPSUM BD.5/8" TYPE 'X' GYPSUM BD.
CONTINUOUS SEALANTCONTINUOUS SEALANTCONTINUOUS SEALANTCONTINUOUS SEALANTCONTINUOUS SEALANTCONTINUOUS SEALANTCONTINUOUS SEALANTCONTINUOUS SEALANT
PARTITION DETAILSPARTITION DETAILSPARTITION DETAILSPARTITION DETAILS
SCALE:SCALE:SCALE:SCALE:
WOOD STUDWOOD STUDWOOD STUDWOOD STUD
TUB LINERTUB LINERTUB LINERTUB LINERTUB LINERTUB LINERTUB LINERTUB LINER
TAPE JOINT
ELEC. BOX @ DEMISING WALL
ELEC. BOX @ DEMISING WALL
ELEC. BOX @ DEMISING WALL
PARTITION
DEMISING
3B
03A
ELEC. PANEL ENCLOSURE
F.E.C. ENCLOSURE
PLAN DETAIL
PLAN
3"=1'-0"
ELECTRICAL COMMUNICATION OR
3" = 1'-0"3" = 1'-0"3" = 1'-0"
FIRE RESISTANT ACOUSTICALFIRE RESISTANT ACOUSTICAL
AROUND BOX PENETRATIONAROUND BOX PENETRATION
OUTLET BOXES SEPARATED
DEMISING PARTITION PER
SEALANT & BACKER RODCABLE OUTLET BOX PER
CONT. BATT INSULATION
EXTINGUISHER CABINET
WALLS ON 1ST AND 2NDRECESSED ELECTRICAL
UL RATINGS SHOWN ON" TYPE 'X' GYPSUM BD -OUTLET BOX PAD (TYP.)OUTLET BOX PAD (TYP.)UL RATINGS SHOWN ON" TYPE 'X' GYPSUM BD -
EXT. FINISH MATERIALSELEC. DRAWINGS (TYP)
PARTITION GYP. BD. TOELEV. & SECTIONS FOR
STUDS AT 16" O.C. FOR
ACOUSTICAL SEALANTACOUSTICAL SEALANT
PLYWOOD FOR SHEARPARTITION - SEE PLAN,
2x4 WOOD STUD - SEE1ST AND 2ND FLOORS;2x4 WOOD STUD - SEE
STAGGERED 4" WOODSTAGGERED 4" WOOD
STUD AT 24" O.C. FORSEMI-RECESSED FIRE
ALL WALL TYPES ANDALL WALL TYPES AND
EXTERIOR PARTITION
PLANS FOR SPECIFICPLANS FOR SPECIFIC
FOR REQUIREMENTSCONTINUE DEMISING
SCALE:WALL INFORMATION.WOOD BLOCKING ASSCALE:SCALE:WALL INFORMATION.SCALE:
WALLS AT DEMISINGSTRUCTURAL DWGS
PLAN & SHEET A8.01
CONT. ACOUSTICAL
FLOORS ONLY; SEE
COORDINATE WITHCOORDINATE WITH
GYP. BD. SIDE OF
ADD ONE LAYEREXTERIOR WALL
BY WOOD STUD
AND LOCATION
SHEET A8.01.SHEET A8.01.
& DETAILING
(E-INSUL-03)3RD FLOOR.
WALL TYPEWALL TYPE
REQUIRED
PANEL
1HR. HORIZ. SHAFTWALL CEILING ASSEMBLY
ACCESSIBLE SHOWER THRESHOLD DETAIL
FLOOR/CEILING DETAIL @ DEMISING WALL
SLIT TAPE JOINT BOTH SIDES
1 LAYER 5/8" TYPE 'X' GYP.
STRUCTURAL DWGS FOR
" RESILIENT CHANNELS
WALLS ON 1ST AND 2ND
PLYWOOD FOR SHEAR
SEALANT BOTH SIDES
REQUIREMENTS AND
WALLS AT DEMISING
ADD ONE LAYER OF
CONT. ACOUSTICAL
FLOORS ONLY; SEE
BD. EACH SIDE
LOCATIONS
PLAN DETAIL
SLAB DEPRESSION
FIRST FLOOR
(-) 0'-3/4"
1 1/2" = 1'-0"
1 1/2"=1'-0"
+0'-0"3" = 1'-0"
3" = 1'-0"
EL:EL:
DEMISING WALLS ON 1ST
SEE STRUCTURAL DWGS
14" WOOD FLOOR TRUSS
AND 2ND FLOORS ONLY;
SEE PLANS & A8.01 FOR
" GYPCRETE TOPPING
CORRIDOR PARTITIONONE LAYER PLYWOODFOR SHEAR WALLS AT
SOUND ATTENUATIONSCALE:
SEALANT BOTH SIDES
FOR REQUIREMENTS
SCALE:BLOCKING AS REQ'D.SCALE:SCALE:
BLOCKING AS REQ'D
SOUND INSULATION
CONT. ACOUSTICAL
WALL ASSEMBLY
AND LOCATIONS
3/4" T&G -O.S.B.
SOLE PLATE
BLANKET
A8.10
Issued for Permit & Construction
Issued for Code Review
University of Iowa
DESCRIPTION
2013 Solomon Cordwell Buenz
ASI-006
ASI-001
10.18.201307.31.201306.07.201305.03.2013
DATE
NO.
2
1
VISION LITE
W/TEMP
GLASS
NOTE: T = TEMPERED SAFETY GLAZING
GL
T
NONE
SCALE:
T
GL
K
NONE
SCALE:
J
NONE
SCALE:
H
Door Schedule
NONE
SCALE:
G
NONE
SCALE:
F
VISION LITE
W/TEMP
GLASS
T
GL
NONE
T
GL SCALE:
Room Finish Schedule
E
VISION LITE
W/TEMP
GLASS
T NONE
GL
SCALE:
D
NONE
SCALE:
C
GLAZING WHEN
RATED DOORS
LOCATED IN
FIREGLASS
DOOR TYPE ELEVATIONS
GL
T
NONE
TGL
TGL
SCALE:
B
Light and Ventilation Schedule
NONE
NTS
SCALE:
SCALE:
A
Window Schedule
A8.11
SEE DR. SCHED.
CLEAR DR. OPNG.
44
""
11
44
""
11
"4
3
MAX.
4
"
4
"
1
3
44
""
11
"2
1
"4
1
44
""
11
2
"
1
44
""
11
2
"
1
Issued for Permit & ConstructionIssued for Permit & Construction
Sheet Number:
E0.00
FAMILY & GRADUATE HOUSING
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
COVER SHEET
DESCRIPTION
ELECTRICAL
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
Dallas, TX 75201
Project Number:
2012042
Checked By:
06.07.201305.03.2013
10th Floor
Drawn By:
DATE
NWS
SRH
NO.
NOTES:
ALL SYMBOLS AND ABBREVIATIONS REFER TO ELECTRICAL/TECHNOLOGY SHEETS ONLY AS DEFINED ON THE SHEET INDEX.
"C#" INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION. REFER TO INFORMATION OUTLET SCHEDULE ON E5.01
ALL SYMBOLS LISTED ABOVE ARE FOR REFERENCE ONLY. REFER TO PLANS AND LINE TYPES KEY FOR NEW, EXISTING TO
REFER TO ACCESS CONTROL SCHEDULE ON E5.01 AND E4.00 FOR DOOR ROUGH-IN AND WIRING DIAGRAM AND ACCESS
2.2.
1.1.
ALL SYMBOLS AND ABBREVIATIONS LISTED MAY NOT BE APPLICABLE TO THIS PROJECT. REFER TO THE GENERAL
FIRE ALARM OPERATION MATRIX
CONTROLLED SECURITY SCHEME SCHEDULE IDENTIFIER
TECHNOLOGY EQUIPMENT SCHEDULE FOR MORE COMPLETE DESCRIPTION AND ITEMS.
TECHNOLOGY SYMBOL NOTES:
SHEET INDEX
TECHNOLOGY SYMBOL LIST
INFORMATION OUTLET (CEILING)
REFER TO THE GENERAL ELECTRICAL NOTES FOR ADDITIONAL INFORMATION.
INFORMATION OUTLET (WALL)
GENERAL NOTES:
REMAIN AND TO BE REMOVED ITEMS FOR ADDITIONAL INFORMATION.
CREDENTIAL READER
DESCRIPTION
ARCH ROOM
NUMBER
X40X40
140140143
TELECOM ROOM REFERENCES
MATERIAL LIST ABBREVIATION
REFERENCE
FLOORPLAN
ONE LINE DIAGRAM NOTES:
2/E2.12
1/E2.121/E2.221/E2.251/E2.32
NO SCALE
FOR ADDITIONAL INFORMATION.
AC-CR-W
SC-IO-C
SC-IO-W
N/A
DETAIL/SHEET
REFERENCE
CONTROL RISER.
1
4/E3.014/E3.02
1/E3.011/E3.027/E3.02
SYMBOL
C#
TELECOMA - HC-1,2
B - HC-1,2
CSS
C#CR
A - MC-2
ROOMB - MC-2C - MC-2
1.2.3.1.2.
ELECTRICAL INSTALLATION NOTES:
GENERAL ELECTRICAL NOTES:
ELECTRICAL SYSTEMS SYMBOL LIST
ELECTRICAL LIGHTING SYMBOL LIST
ELECTRICAL POWER SYMBOL LIST
LUMINAIRE SYMBOL KEY
Issued for Permit & Construction
Sheet Number:
E0.10
FAMILY & GRADUATE HOUSING
Construction US
Issued for Code Review
A3
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
ELECTRICAL
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
SITE PLAN
Dallas, TX 75201
N.T.S.Project Number:
A2
B2
2012042
Checked By:
06.07.201305.03.2013
SCALE:
10th Floor
Drawn By:
DATE
NWS
SRH
B1
NO.
A1
C
Issued for Permit & Construction
Sheet Number:
E2.10
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
R
R
Issued for Permit & Construction
Sheet Number:
E2.11
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
R
R
Issued for Permit & Construction
Sheet Number:
E2.20
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
192
R
R
191
Issued for Permit & Construction
Sheet Number:
E2.21
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
192
R
R
191
Issued for Permit & Construction
Sheet Number:
E2.23
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
Issued for Permit & Construction
Sheet Number:
E2.24
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
Issued for Permit & Construction
Sheet Number:
E2.30
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
PURPOSE
MULTI-
101
PANTRY
101A
MEDIA ROOM
PURPOSE
MULTI-
101B
R
ELECTRICAL
STORAGE
DATA/
143
142
VESTIBULE
ENTRY
100
CORRIDOR
100B
VESTIBULE /
VENDING
ENTRY
100D
RECEPTION
100A
MAIL
100E
FITNESS
105
OFFICE
102
OFFICE
103
RESTROOM
WOMEN'S
107
LAUNDRY
WORK ROOM
106
104
RESTROOM
MEN'S
108
MAINTENANCE
141
MECHANICAL
140
Issued for Permit & Construction
Sheet Number:
E4.00
FAMILY & GRADUATE HOUSING
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
DESCRIPTION
ELECTRICAL
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
Dallas, TX 75201
Project Number:
DETAILS
2012042
Checked By:
06.07.201305.03.2013
10th Floor
Drawn By:
DATE
NMHMAW
NO.
MINIMUM ACCEPTABLE
BONDING CONDUCTOR SIZING SCHEDULE
SIZE - AWG
TECHNOLOGY BONDING RISER DIAGRAM (TYP)CONDUCTOR LENGTH
ACCESS CONTROL RISER DIAGRAM
IN FEET
FLOOR
FIRST
NO SCALE
6
NO SCALE
3
SECOND
FLOORFLOORFLOOR
THIRDFIRST
FIRE RATED CABLE PATHWAY DETAIL
TYPICAL TELECOM ROOM BONDING FLOW DIAGRAM
NO SCALE
5
NO SCALE
2
DOOR ROUGH-IN AND WIRING DIAGRAMS
GROUND BAR DETAIL
NO SCALENO SCALE
14
Issued for Permit & Construction
Sheet Number:
E4.01
FAMILY & GRADUATE HOUSING
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
DESCRIPTION
ELECTRICAL
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
Dallas, TX 75201
Project Number:
DETAILS
2012042
Checked By:
06.07.201305.03.2013
10th Floor
Drawn By:
DATE
NMHMAW
NO.
BUILDING TYPES A & B - TECHNOLOGY RISER DIAGRAM
BUILDING TYPE C - TECHNOLOGY RISER DIAGRAM
NO SCALENO SCALE
FLOOR
1ST
24
FLOOR
FLOOR
FLOOR
3RD1ST
2ND
BUILDING TYPES A & B - PARTIAL CABLE T.V. RISER DIAGRAM
BUILDING TYPE C - PARTIAL CABLE T.V. RISER DIAGRAM
NO SCALENO SCALE
FLOOR
1ST
13
FLOORFLOORFLOOR
1ST
3RD2ND
Issued for Permit & Construction
Sheet Number:
E4.02
FAMILY & GRADUATE HOUSING
Construction US
Balfour Beatty
University of Iowa
DESCRIPTION
ELECTRICAL
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
Dallas, TX 75201
Project Number:
DETAILS
2012042
Checked By:
06.07.2013
10th Floor
Drawn By:
DATE
NWS
SRH
NO.
AHU & SMOKE DAMPER SHUT DOWN
NO SCALE
4
CONDUIT ROOF PENETRATION DETAIL
ADDRESSABLE FIRE ALARM SYSTEM DIAGRAM
NO SCALE
3
NO SCALE
6
EMERGENCY LIGHTING CIRCUITRY DETAIL
SMOKE DOOR RELEASE DETAIL
NO SCALENO SCALE
15
Issued for Permit & Construction
Sheet Number:
E5.01
FAMILY & GRADUATE HOUSING
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
DESCRIPTION
ELECTRICAL
3100 McKinnon Street
SCHEDULES
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
Dallas, TX 75201
Project Number:
2012042
Checked By:
06.07.201305.03.2013
10th Floor
Drawn By:
DATE
NMHMAW
NO.
GENERAL TECHNOLOGY EQUIPMENT SCHEDULE
PIN/PAIR ASSIGNMENT
ANSI/TIA/EIA T568B
BR
PAIR 4
8
WBR
7
G
6
WBL
PAIR 3PAIR 1
5
BL
4
WG
3
PAIR 2
2O
WO
1
JACK LEGEND
SCHEDULE NOTES
INFORMATION OUTLET SCHEDULE
2-PORT FACEPLATE
IDENTIFICATIONIDENTIFICATION
FACEPLATE FEATURES
1-PORT FACEPLATE
IDENTIFICATIONIDENTIFICATION
CONFIGURATION
Issued for Permit & Construction
Sheet Number:
F2.10
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
T
T
R
O
R
O
Issued for Permit & Construction
Sheet Number:
F2.20
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
192
H
T
R
N
H
T
R
N
191
Issued for Permit & Construction
Sheet Number:
F2.21
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
UNIT X15
X00E
X92
X41
X40
X00A
H
T
R
N
H
T
R
O
N
X00A
X91
UP
Issued for Permit & Construction
Sheet Number:
F5.10
FIRE PROTECTION
FAMILY & GRADUATE HOUSING
Issued for Code Review
MATERIAL LIST
University of Iowa
DETAILS AND
DESCRIPTION
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
Project Number:
2012042
Checked By:
06.07.201305.03.2013
Drawn By:
DATE
DCI
BTO
NO.
NOTES 2, 3, 7
REMARKS
NOTE 3, 7
SYMBOL IS PRIMARILY FOR INDENTIFYING SPRINKLERS IN SUBMITTALS. IT MAY OR MAY NOT BE FOUND ELSEWHERE ON THE DRAWINGS. CONTRACTOR TO SUBMIT ALL SPRINKLER TYPES TO BE USED.
TYCO TY-FRB, VICTAULIC V2710
VIKING VK, RELIABLE F1FR,
TYCO RFII, VICTAULIC V3802
VIKING VK, RELIABLE G4A,
MANUFACTURER & MODEL
CONTRACTOR TO VERIFY SPRINKLER REQUIREMENTS BASED ON ACTUAL INSTALLATION, USAGE, ARCHITECTURAL CEILING PLAN AND NFPA 13R REQUIREMENTS.
••••••••••••••••••••••
TEMPERATURE
155, 200
155
WHITEWHITE
FINISH
RESPONSE
AREAS ARE GENERAL IN NATURE. CONTRACTOR TO MATCH UNSCHEDULED AREAS TO SIMILAR SPACES.
SPRINKLER
QUICKQUICK
RECESSED SIDEWALL
RESIDENTIALRESIDENTIAL
CONCEALED
FIRE SPRINKLER USAGE SCHEDULE TYPE
TEMPERATURE RATINGS SHALL BE BASED ON REQUIREMENTS IN NFPA 13.
SPRINKLER SHALL HAVE COLOR CODED BULB THERMAL ELEMENT.
(NOTES 4 & 5)
SYMBOL
SPR-1SPR-2
SPRINKLERS SHALL HAVE A 3mm QUICK RESPONSE BULB.
SEE FLOOR PLANS FOR ZONING REQUIREMENTS.
CORRIDORS, AUXILLARYCORRIDORS, AUXILLARY
RESIDENT ROOMS,RESIDENT ROOMS,
AREA HAZARD
ALL SPRINKLERS SHALL BE UL LISTED.
SPACESSPACES
RATED FIRE BARRIER (WALL) PENETRATION
1ST AND 2ND FLOOR
DROP CEILINGS
(NOTE 1 & 6)
AREA TYPE3RD FLOOR
NOTES:
1.2.3.4.5.6.7.8.
PIPE THROUGH NON-FIRE RATED WALL
NO SCALE
2
NO SCALE
4
RATED FIRE BARRIER (FLOOR) PENETRATION
FIRE PROTECTION RISER DIAGRAM
KEYNOTES
NO SCALE
NO SCALE
1
3
Issued for Permit & Construction
M0.00
Sheet Number:
FAMILY & GRADUATE HOUSING
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
COVER SHEET
MECHANICAL
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
Dallas, TX 75201
Project Number:
2012042
Checked By:
06.07.201305.03.2013
10th Floor
Drawn By:
DATE
LDP
SLS
NO.
Issued for Permit & Construction
M2.10
Sheet Number:
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
H
H
TT
RR
O
N
N
Issued for Permit & ConstructionIssued for Permit & Construction
BUILDING TYPE A -
M2.11
Sheet Number:Sheet Number:
FAMILY & GRADUATE HOUSINGFAMILY & GRADUATE HOUSING
Construction USConstruction US
A3A3
Balfour BeattyBalfour Beatty
University of IowaUniversity of Iowa
KEY SITE PLANKEY SITE PLAN ROOF PLAN -
MECHANICAL
DESCRIPTIONDESCRIPTION
3100 McKinnon Street3100 McKinnon Street
2013 Solomon Cordwell Buenz2013 Solomon Cordwell Buenz
101 Hawkeye Court101 Hawkeye Court
Iowa City, IA 52246Iowa City, IA 52246
Dallas, TX 75201Dallas, TX 75201
N.T.S.N.T.S.Project Number:Project Number:
A2A2
B2B2
20120422012042
Checked By:Checked By:
06.07.201306.07.2013
SCALE:SCALE:
10th Floor10th Floor
Drawn By:Drawn By:
DATEDATE
B1B1LDP
SLS
NO.NO.
A1A1
CC
GENERAL MECHANICAL NOTES
KEYNOTES
BUILDINGS A1, A2 & A3 - ATTIC AND ROOF PLAN - MECHANICAL
SCALE: 1/8"=1'-0"
1
H
T
R
O
N
Issued for Permit & Construction
M2.20
Sheet Number:
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
192
H
R
N
H
R
N
191
Issued for Permit & Construction
M2.21
Sheet Number:
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
UNIT X15
X00E
X92
X41
X40
X00A
H
T
R
N
H
T
R
N
X00A
X91
UP
Issued for Permit & Construction
M2.22
Sheet Number:
FAMILY & GRADUATE HOUSING
Construction USBUILDING TYPE B
A3
Balfour Beatty
University of Iowa
- ROOF PLAN -
KEY SITE PLAN
MECHANICAL
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
Dallas, TX 75201
N.T.S.Project Number:
A2
B2
2012042
Checked By:
06.07.2013
SCALE:
10th Floor
Drawn By:
DATE
B1LDP
SLS
NO.
A1
C
GENERAL MECHANICAL NOTES
KEYNOTES
BUILDINGS B1 & B2 - ROOF PLAN - MECHANICAL
SCALE: 1/8"=1'-0"
1
H
BLD. B2
T
R
O
N
BLD. B1
H
T
R
O
N
Issued for Permit & Construction
M2.30
Sheet Number:
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
PURPOSE
MULTI-
101
PANTRY
101A
MEDIA ROOM
PURPOSE
MULTI-
101B
ELECTRICAL
STORAGE
DATA/
143
142
VESTIBULE
ENTRY
100
CORRIDOR
100B
VESTIBULE /
VENDING
ENTRY
100D
RECEPTION
100A
MAIL
100E
FITNESS
105
OFFICE
102
H
T
R
N
OFFICE
103
RESTROOM
WOMEN'S
107
LAUNDRY
WORK ROOM
106
104
RESTROOM
MEN'S
108
MAINTENANCE
141
MECHANICAL
140
Issued for Permit & Construction
M2.31
Sheet Number:
FAMILY & GRADUATE HOUSING
Construction US
A3
Balfour Beatty
University of Iowa
KEY SITE PLAN ROOF PLAN -
BUILDING C -MECHANICAL
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
Dallas, TX 75201
N.T.S.Project Number:
A2
B2
2012042
Checked By:
06.07.2013
SCALE:
10th Floor
Drawn By:
DATE
B1LDP
SLS
NO.
A1
C
GENERAL MECHANICAL NOTES
MECHANICAL KEYNOTES
BUILDING C - ROOF PLAN - MECHANICAL
SCALE: 1/4"=1'-0"
1
H
T
R
O
N
Issued for Permit & Construction
M3.10
Sheet Number:
FAMILY & GRADUATE HOUSING
Construction US
Issued for Code Review
A3
Balfour Beatty
University of Iowa
KEY SITE PLAN
MECHANICAL
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
ENLARGED
101 Hawkeye Court
Iowa City, IA 52246
Dallas, TX 75201
N.T.S.PLANS -Project Number:
A2
B2
2012042
Checked By:
06.07.201305.03.2013
SCALE:
10th Floor
Drawn By:
DATE
B1LDP
SLS
NO.
A1
C
GENERAL MECHANICAL NOTES
MECHANICAL KEYNOTES
1ST FLOOR 2 BED / 2 BATH ENLARGED PLAN - MECHANICAL
SCALE: 1/4"=1'-0"
3
1ST FLOOR 2 BED / 1 BATH ENLARGED PLAN - MECHANICAL
SCALE: 1/4"=1'-0"
2
1ST FLOOR 1 BED / 1 BATH ENLARGED PLAN - MECHANICAL
SCALE: 1/4"=1'-0"
1
Issued for Permit & Construction
M4.10
Sheet Number:
FAMILY & GRADUATE HOUSING
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
MECHANICAL
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
Dallas, TX 75201
Project Number:
DETAILS
2012042
Checked By:
06.07.201305.03.2013
10th Floor
Drawn By:
DATE
LDP
SLS
NO.
SUPPLY GRILLE W/ CEILING RADIATION DAMPER DETAIL••••••••••••••••••••••••••••••••••••••••••••••
FIRE DAMPER THRU WALL DETAIL
TYPE "A"
NO SCALE
8
NO SCALE
4
NO SCALE
METAL ROOF MOUNTED EXHAUST FAN
12
AIR HANDLING UNIT PAD DETAIL
DRIP PAN DETAIL
NO SCALE
NO SCALE
7
3
NO SCALE
11
FURNACE UNIT (BOTTOM RETURN) DETAIL
DIFFUSER CONNECTION DETAIL
TRANSFER DUCT DETAIL
NO SCALE
NO SCALE
26
NO SCALE
10
FURNACE UNIT (SIDE RETURN) DETAIL
CONCENTRIC COMBUSTION AIR/VENT
THRU ROOF (SHINGLE ROOF)
SUPPLY REGISTER DETAIL
NO SCALENO SCALE
NO SCALE
59
1
Issued for Permit & Construction
M5.10
Sheet Number:
FAMILY & GRADUATE HOUSING
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
MECHANICAL
DESCRIPTION
3100 McKinnon Street
SCHEDULES
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
Dallas, TX 75201
Project Number:
2012042
Checked By:
06.07.201305.03.2013
10th Floor
Drawn By:
DATE
LDP
SLS
NO.
BLADES PARALLEL TO THE SHORTER INLET
FRONT BLADES VERTICAL UNLESS NOTEDFRONT BLADES VERTICAL UNLESS NOTED
DIMENSION UNLESS OTHERWISE NOTED.
REMARKS
NOTES 1, 2, 3NOTES 1, 2, 3NOTES 1, 2, 3
NOTE 2, 3, 4
REMARKSREMARKSREMARKS
NOTE 1, 5
NOTE 1NOTE 1NOTE 2NOTE 2
REMARKS
NOTE 1NOTE 1
FACE ONLY - NON DUCTEDFACE ONLY - NON DUCTED
FFE-080FFE-030FFE-080
FFJ-060FFJ-030
MODELMODELMODEL
ZB80
UHECUHEC
FLUSH FACE PANELFLUSH FACE PANELFLUSH FACE PANELG
RMXS48LVJU
EVAP.MODEL3MXS24JVJU3MXS24JVJU3MXS24JVJU3MXS24JVJU3MXS24JVJU
COND UNIT
COIL
CAP
MODEL
MANUFACTURERMANUFACTURERMANUFACTURER
OTHERWISEOTHERWISE
GREENHECK
REMARKS
TRANETRANETRANETRANETRANEBROANTRANETRANE
COND.
MODEL
GSX13
UNIT
CONDENSING UNIT
MANUFACTURER
DAIKINDAIKINDAIKINDAIKINDAIKINDAIKIN
TYPE (NOTE C)
CONTROL
NOTE 1NOTE 1
CONTROLLER/
MODEL
OMNIOMNIS300FSOMNI
BY (NOTE A)
FURNACE
350R350R300R301R
PXPPXPCONTROLLER/STARTER
MODEL
STARTER
GKS9
FVSS
MFRMFRMFRMFRMFR
CONTROLLER/STARTER
CONTROLLER/
BY (NOTE A)BY (NOTE A)
BY (NOTE A)
MANUFACTURERMANUFACTURER
STARTER
(NOTE B)
MFR/ECMFR/ECMFR/ECMFR/ECMFR/ECMFR/EC
GOODMAN
MFR
MFRMFR
EC
TYPE
TITUSTITUSTITUSTITUSTITUSTITUSTITUSTITUSTITUSTITUS
NFNFNFNFNF
DISCONNECT
(NOTE A)
TYPE (NOTE B)
BYECECECECEC
TYPE (NOTE B)(NOTE B)
NFNF
CONTROLLER/TYPE
DISCONNECT
ELECTRICALBY (NOTE A)NFNFNFNFNFNF
GRILLES REGISTERS & DIFFUSERS SCHEDULE
NOTE 3
WHITEWHITEWHITEWHITEWHITEWHITEWHITEWHITEWHITE
FINISHDISCONNECT
NFNF
STARTER
48.838.021.721.728.8
FLA
ELECTRICAL
DISCONNECTMFR
BY (NOTE A)
(NOTE A)
CONTRACTOR SHALL DETERMINE PROPER MARGIN STYLE TO MATCH CEILING CONSTRUCTION.
PHASE/
VOLT/
208/1/2208/1/2208/1/2208/1/2208/3/3
MFR
CONDENSING UNIT
WIREECBY (NOTE A)
ALL RUN OUT DUCTWORK TO DIFFUSERS SHALL BE NECK SIZE UNLESS OTHERWISE NOTED.
ECECECECECEC
VOLUMEDAMPERBY
REQ'D
MFR.MFR.
YESYESYES
NONONONONONONO
(NOTE B)
TYPE
ELEMENT
4.5 / 10.1
ELECTRICAL
4.5/10.1
3.4 / 7.91.5 / 4.51.5 / 4.5
NF
VOLT-
PHASE
120-1120-1
DISCONNECT
MOCPAMPS
KW
302020202020
INLET +2INLET +2INLET +2INLET +2INLET +2
(INCH)
24x2424x2424x2424x4824x24MOCP
FACE
SIZE35.035.0
(NOTE E)
(NOTE A)
HEATING
STAGES
MHP
1/8MCA17.817.817.817.817.8
22222-
27
CUSTOM COLOR - COORDINATE COLOR SELECTION WITH ARCHITECT.BYEC
FLA/
24.1
13.9
RLA
SEE DWG.SEE DWG.SEE DWG.SEE DWG.SEE DWG.SEE DWG.SEE DWG.SEE DWG.
(INCH)
INLET
SIZE
(NOTE E)
N/AN/A
WATTS
1,0801,0301,080
RPM9809800.06
BHP
••••••••••••••••••••••••••••••••••••••••••••••••••••••••7.6
23.3
RLA11.711.711.711.711.7
MOCPAMPS
VOLT/
PHASE
208/115.0
208/3
CONDENSING UNIT
FAN HPPROVIDE LOW VOLTAGE WALL MOUNTED THERMOSTAT. PROVIDE CONTROL TRANSFORMER AS REQUIRED.
(NOTE 1)(NOTE G)
1/251/25
MARGIN
1/81/81/8
LAY-INLAY-INLAY-IN1 1/4"1 1/4"LAY-IN1 1/4"1 1/4"1 1/4"LAY-INCURB
TYPE
MFRVOLT-
PHASE
-208/1208/1208/1208/1208/1208/1
PROVIDE WITH MANUFACTURER-SUPPLIED CEILING RADIATION DAMPER FOR USE WITH RATED FLOOR/CEILING ASSEMBLIES.
MCA
9.1
5.05.0
KW
10"10"10"10"10"
D
TERMINATION
BACKDRAFT
GRAVITY AT
DAMPER
PERFORATEDPERFORATED
PANEL FACEPANEL FACEDEFLECTIONDEFLECTIONDEFLECTIONPANEL FACE
VOLT-
PHASE
MOD
1,5501,550208-1COP
CABINETEF-2 SHALL TURN ON WHEN AHU-1 IS IN OCCUPIED MODE AND TURN OFF WHEN AHU-1 IS IN UNOCCUPIED MODE.RPM2.93.23.23.23.23.2
DOUBLEDOUBLE
SINGLE
2'-6"4'-8"2'-9"2'-6"2'-6"
TYPEFACEFACE
W
UNIT HEATER SCHEDULE - ELECTRIC
MOUNT UNIT HEATERS AT MANUFACTURERS RECOMMENDED MOUNTING HEIGHT.
FAN HP
PROVIDE WALL MOUNTED SENSOR WITH ADJUSTABLE SETPOINT AND ADJUSTABLE FAN SPEED OPTIONS.
1/1251/125
HEATING
PROVIDE FACTORY PRIME COAT FOR FIELD APPLICATION OF FINAL FINISH. FIELD PAINT BY OTHERS.
4'-10"
2'-1"2'-1"3'-0"3'-0"MBH
SEER
543030303030
SONES
HMAX.13
AMCA
0.37.4
STAGES
ALUMINUMALUMINUM
CONTROL
STEELSTEELSTEELSTEELSTEELSTEELSTEELSTEEL11
MAT'L
CABINET HEATER SCHEDULE - ELECTRIC
WALLTSTATWALLTSTATWALLTSTATWALLTSTATWALLTSTAT
MBH
16
PROVIDE SOLID STATE SPEED CONTROLLER MOUNTED INTERNALLY IN FAN HOUSING.
DIRECTDIRECT12.512.512.512.512.5
EER
9.8
DRIVE
••••••••••••
••••
TEMP
RISE
4040
NOMINAL
AMBIENT
SYMBOL
730500250300730
CFM
(NOTE F)
POWER TO FAN COIL UNITS IS PROVIDED BY POWER WIRING FROM THE OUTDOOR CONDENSING UNIT. EC TO FURNISH AND INSTALL POWER AND CONTROL WIRING BETWEEN CONDENSING UNIT AND INDOOR FAN COIL UNITS
AND ALL DISCONNECTS.
NOTES:
CD-1CD-2RG-1SG-1SR-1EG-195
RG-2RG-3RG-4SR-2
COOLING
1,550
FANRPMCFM400400
-MBH
482424242424
2.
1.3.
VERTICAL CABINET SLOPE TOPVERTICAL CABINET SLOPE TOP
••••••••••••
PROVIDE BOTTOM STAMPED INLET AND OUTLET CONFIGURATION.SYMBOL
HORIZONTALHORIZONTAL
WHEELINCHES
LIGHT SWITCH IN BATHROOM SHALL CONTROL EXHAUST FAN.
DIA.
- TOE SPACE RETURN- TOE SPACE RETURNCU-1
COMMUNITY CENTER
CEILING RECESSEDCEILING RECESSEDCEILING RECESSED8.5
-
TYPE
AMBIENT
959595959595
TYPE
W.C.
S.P.
IN.0.350.50
TOTAL
COORDINATE COLOR SELECTION WITH ARCHITECT.
MBH
16
MECHANICAL
COMMUNITY
SYMBOL
SERVICE
CENTER
ROOMS
••••••••
CU-2CU-3CU-4CU-5CU-6CU-7
EVAPORATOR
300
CFM
80
63
FAN SCHEDULE••••••••
RESIDENCE HALL FIRSTRESIDENCE HALL FIRST
COMMUNITY CENTER
EAT
APARTMENT UNIT
FLOOR CORRIDORSFLOOR CORRIDORSSYMBOL
RESIDENCE HALL
NOTES:
UH-1
BATHROOMSUH-2
RESTROOMS
VESTIBULESSTAIRWELLS
CORRIDORSNOTES 2, 3NOTES 2, 3NOTES 2, 3
SERVICE
REMARKSNOTE 2, 4NOTE 2, 4NOTE 2, 4NOTE 2, 4NOTE 2, 4NOTE 2, 4NOTE 2, 4NOTE 2, 4NOTE 2, 4NOTE 2, 4NOTE 2, 4NOTE 2, 4NOTE 2, 4NOTE 2, 4NOTE 2, 4
SERVICE75
2.
1.
OUTPUT
MIN.
42.8
SYMBOL
HEATING
FAN COIL UNIT
NOTES:
EF-1
EF-2
CTXS09HVJUCTXS09HVJU
FTXS18LVJU
SYMBOL
FFQ12LVJUFFQ15LVJUFFQ09LVJUFFQ09LVJUFFQ09LVJUFFQ09LVJUFFQ09LVJUFFQ09LVJUFFQ09LVJUFFQ09LVJUFFQ09LVJUFFQ09LVJUFFQ09LVJUFFQ09LVJUFFQ09LVJU
CAB-1CAB-2CAB-3CAB-4CAB-5
NOTES:
MODEL
EFFICIENCY
1.2.3.4.5.
92.1
1.2.3.
MIN
MANUFACTURER
CONTROLLER/FAN COIL UNIT
BY (NOTE A)
PROVIDE ECONOMIZER WITH BAROMETRIC RELIEF. ECONOMIZER SHALL BE CONTROLLED AROUND DIFFERENTIAL ENTHALPY.
STARTER
DAIKINDAIKINDAIKINDAIKINDAIKINDAIKINDAIKINDAIKINDAIKINDAIKINDAIKINDAIKINDAIKINDAIKINDAIKINDAIKINDAIKINDAIKIN
MFR
POWER TO FAN COIL UNITS IS PROVIDED BY POWER WIRING FROM BRANCH PORT TO EACH FAN COIL UNIT. SEPARATE POWER CONNECTION IS NOT REQUIRED.
PROVIDE 7 DAY PROGRAMMABLE THERMOSTAT WITH NIGHT SETBACK, HUMIDITY SENSOR, AND CO2 SENSOR.
(NOTE B)
CONTROLLER/
BY (NOTE A)
TYPE
NF
STARTER
INCLUDE BRANCH PORT UNIT MODEL BPMKS049A3U. BRANCH PORT UNIT ELECTRICAL REQUIREMENTS: 208V/1-PHASE, MCA: 0.1 A, MOCP: 15 A.
DISCONNECT
MFRMFRMFRMFRMFRMFRMFRMFRMFRMFRMFRMFRMFRMFRMFRMFRMFRMFR
PROVIDE 7 DAY PROGRAMMABLE THERMOSTAT WITH NIGHT SETBACK AND HUMIDITY SENSOR.
(NOTE A)
ELECTRICAL
MFR
BUILDING ASSEMBLYBY
NOTE 1, 2, 3, 4, 5, 7
COMMUNITY
2" - MERV 8
(NOTE B)
ELECTRICAL
12.5 EERYHC120
PACKAGED AIR CONDITIONING UNIT
TRANE
AHU-2R410A208 / 3
95.00
3,5151,35550.30
0.7578.565.3
1.7366012014"113
MFRMFR
0.8NF
84575560FV
2
BYNFNFNFNFNFNFNFNFNFNFNFNFNFNFNFNFNFNF
DISCONNECT
MOCP
15
INDOOR FAN COIL UNIT
••••••••••••••••••••••••••••••••••••••••••••
(NOTE A)
BUILDING OFFICESNOTE 1, 2, 3, 4, 5, 6
BYECECECECECECECECECECECECECECECECECEC
••••••••••••••••••••••••••••
SCHEDULE - GAS/ELECTRIC
COMMUNITY2" - MERV 8
MCA14.4
PROVIDE SMOKE DETECTOR IN SUPPLY AIR DUCT ON UNIT.
YHC102
TRANE
AHU-113 EER208 / 3
R410A
3,5151,44895.0042.00
1.002.14
37012014"MFRMFR
NF
0.884776458559050FV
3
••••••••••••••••••••••••••••••••••••••••••••••••••••••
VOLT-
PHASE
208/1208/1208/1208/1208/1208/1208/1208/1208/1208/1208/1208/1208/1208/1208/1208/1208/1208/1
VOLT-
PHASE
120/1
FURNACE SCHEDULE (NATURAL GAS / DIRECT EXPANSION)
FAN RPM (NOTE D)BHP (NOTE E)MHP (NOTE E)GAS PRESSURE IN. W.C.DISCONNECT BY (NOTE A)
DISCONNECT TYPE (NOTE B)CONTROLLER/STARTER BY (NOTE A)CONTROLLER/STARTER TYPE (NOTE C)
REFRIGERANTTYPEMOCP AMPSPROVIDE CONVENIENCE POWER OUTLET.
EXTERNAL STATIC PRESSUREMINIMUM EFFICIENCY AFUEHIGH OUTPUT MBHLOW OUTPUT MBHTOTAL MBHMINIMUM EFFICIENCYVELOCITYVOLT-PHASEMCA
CFM
PROVIDE HOT GAS REHEAT WITH UNITS.
LAT LISTED IS AT DISCHARGE OF RTU.
SPLIT SYSTEM HEAT PUMP SCHEDULE
SPEED)
(HIGH
CFM353424583318318318318318318318318318318318318388318388
UPFLOW
TYPE
FLOW
AIR
MINIMUM OUTSIDE AIR CFM
CAPACITY
(RATED)
HEATING - 2 STAGE GAS
HEATING
1,050
RPM
MBH14.017.521.611.111.111.111.111.111.111.111.111.111.111.111.110.011.110.0
COOLING COIL - DX
MANUFACTURER
MODEL NUMBER
ELECTRICAL
SUPPLY FAN
REMARKS
1/2
HP
SYMBOLSERVICE
(RATED)
COOLING
NOTES:
FILTER
TOTAL
MBH
12.015.018.0
9.59.59.59.59.59.59.59.59.59.59.59.58.59.58.5
2.4.
1.3.5.6.7.
FAN/BLOWER
INCLUDING COIL )
IN. W.C. (NOT
REMARKS
NOTE 1, 2NOTE 1, 3NOTE 1, 4
EXT. S.P.
WALL-MOUNTEDWALL-MOUNTEDWALL-MOUNTED
FAN COIL UNIT
0.5
CASSETTECASSETTECASSETTECASSETTECASSETTECASSETTECASSETTECASSETTECASSETTECASSETTECASSETTECASSETTECASSETTECASSETTECASSETTE
CEILINGCEILINGCEILINGCEILINGCEILINGCEILINGCEILINGCEILINGCEILINGCEILINGCEILINGCEILINGCEILINGCEILINGCEILINGINCLUDE INTEGRAL CONDENSATE PUMP.
STYLE
FEEDBACK
POSITIVEPOSITION
NONONO
SPEED)
(HIGH
1,200
CFMBLDG B - LOBBYCORRIDOR 100ECORRIDOR 200ECORRIDOR 300EBLDG A - LOBBY
CORRIDOR 200ACORRIDOR 300ACORRIDOR 100ACORRIDOR 200ACORRIDOR 300ACORRIDOR 100DCORRIDOR 200DCORRIDOR 300D
CORRIDOR 100WCORRIDOR 200WCORRIDOR 300W
CORRIDOR 200CORRIROR 300
BLDG B -BLDG B -BLDG B -BLDG B -BLDG B -BLDG B -BLDG B -BLDG B -BLDG A -BLDG A -BLDG A -BLDG A -BLDG A -BLDG A -BLDG A -BLDG A -
SERVICE
REMARKS
POSITION
FAILURE100C
CLOSEDCLOSEDCLOSED
NOTE 2NOTE 2100
POWER
WITH THE SCHEDULED WHEEL TYPE. SUBSTITUTION OF BI OR BIA FANS
FURNISH WITH SEVEN DAY PROGRAMMABLE THERMOSTAT.
MOTOR
TYPE
ECM
MODEL
MC = FURNISHED BY MECHANICAL CONTRACTOR, INSTALLED
ACTUATOR2 POSITION2 POSITION2 POSITION
FGRFGR
STYLE
FANS FOR FC IS ACCEPTABLE IF EFFICIENCY IS NOT LOWER.SYMBOL
FCU-2AFCU-2BFCU-2CFCU-3AFCU-3BFCU-3CFCU-4AFCU-4BFCU-4CFCU-5AFCU-5BFCU-5CFCU-6AFCU-6BFCU-6CFCU-7AFCU-7BFCU-7C
NOTES:
D. FAN RPM SHALL NOT EXCEED 110% OF SCHEDULED VALUE,E. NO EQUIPMENT SHALL BE SELECTED ABOVE 90% OF MOTOR
DISCONNECT AND CONTROLLER STARTER FURNISHED ANDIN. W.C.
EXT.
S.P.
0.5
INSTALLED BY ELECTRICAL CONTRACTORVFD/B = VARIABLE FREQUENCY DRIVE WITH BYPASS
MOD-2 SHALL BE OPEN WHEN AHU-1 OR AHU-2 SUPPLY FAN IS ON AND CLOSE WHEN SUPPLY FAN IS OFF. PROVIDE ALL REQUIRED RELAYS.MOD-3 SHALL BE OPEN WHEN AHU-1 OR AHU-2 SUPPLY FAN IS ON AND CLOSE
WHEN SUPPLY FAN IS OFF. PROVIDE ALL REQUIRED RELAYS.
MANUFACTURER
1.2.3.4.
FURNISHED LOOSE BY MANUFACTURER
GREENHECKGREENHECK
POWER
120-1120-1120-1
MFR = STANDARD CURB BY MANUFACTURER
F. MUST BE WITHIN +/- 10% OF SCHEDULED RPM.
SPEED
1,200
HIGH
CFM
SS = SOLID STATE SPEED CONTROLLER
BY ELECTRICAL CONTRACTOR
VFD = VARIABLE FREQUENCY DRIVE
ACTUATOR
SCHEDULE GENERAL NOTES:
ELECTRICELECTRICELECTRIC
EC = ELECTRICAL CONTRACTOR.
GC = BY GENERAL CONTRACTOR
TYPE
CURBAPARTMENT
MFRMFR
SERVICE
COORDINATE DAMPER ACTUATOR LOCATION AND MOUNTING REQUIREMENTS WITH ELECTRICAL CONTRACTOR.
CONTROLLER STARTER TYPE:UNITS
MS = MANUAL STARTER
MFR = MANUFACTURER
INSULATED
FV = FULL VOLTAGEDAMPER
NOTE 1NOTE 1
NAME PLATE RATING.
YESYESYES
WYE = WYE-DELTATYPE
PROVIDE FACTORY PRIME COAT FOR FIELD APPLICATION OF FINAL FINISH. FIELD PAINT BY OTHERS.
DISCONNECT TYPE:
NF = NON-FUSED
SYMBOL
INSTALLED BY:
NOTES:
F-1
F = FUSED
MFR/EC =
G. CURB TYPE:
OR VERTICAL
HORIZONTALHORIZONTALHORIZONTALHORIZONTAL
MOTOR OPERATED DAMPER SCHEDULE MOD-1 SHALL OPEN UPON ACTIVATION OF EF-1 AND CLOSE UPON DEACTIVATION OF EF-1.
ROOF HOODROOF HOOD
BLADES1.
TYPE
PROVIDE BAROMETRIC RELIEF DAMPER SET TO MAINTAIN 0.05" OF W.C IN SPACE.
A.
B.C.
FREE AREA
OPPOSED OR
PARALLELPARALLELPARALLELPARALLEL
9.179.17BLADES
Changed through
RFI #005
VELOCITY
THROAT
(SQFT)
20x6620x66
SIZE
MIN.
000
ROOF HOOD SCHEDULE
CFM
MAX.
3,5153,515
3,5153,515300
CFM
COMMUNITY BUILDINGCOMMUNITY BUILDING
10x1020x6620x66
W x H(IN.)
SIZE
SERVICEOFFICESOFFICES
SERVICE
EF-1RH-1
RH-2
EF-2
SYMBOLSYMBOL
MOD-1
MOD-2MOD-3
NOTES:NOTES:
RH-1RH-2
1.2.1.2.3.4.
Issued for Permit & Construction
BUILDING TYPE A -
Sheet Number:
P2.10
PLAN - PLUMBING
FAMILY & GRADUATE HOUSING
Construction US
Issued for Code Review
A3 Balfour Beatty
University of Iowa
UNDER FLOOR
KEY SITE PLAN
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
ASI-003
Iowa City, IA 52246
Dallas, TX 75201
N.T.S.Project Number:
A2
B2
2012042
Checked By:
08.14.201306.07.201305.03.2013
SCALE:
10th Floor
Drawn By:
DATE
MED
RDP
B1
NO.
A1
C
BUILDINGS A1, A2 & A3 - UNDER FLOOR PLAN - PLUMBING
SCALE: 1/8" = 1'-0"
1
H
T
R
O
N
Issued for Permit & Construction
Sheet Number:
P2.11
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
ASI-007ASI-003
N.T.S.
Checked By:
08.14.201306.07.201305.03.2013
SCALE:
10.21.2013
Drawn By:
DATE
NO.
H
H
T
T
R
R
O
N
N
Issued for Permit & Construction
BUILDING TYPE A -
Sheet Number:
P2.12
FAMILY & GRADUATE HOUSING
Construction US
A3
Balfour Beatty
University of Iowa
KEY SITE PLAN ROOF PLAN -
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
ASI-003
Iowa City, IA 52246
PLUMBING
Dallas, TX 75201
N.T.S.Project Number:
A2
B2
2012042
Checked By:
08.14.201306.07.2013
SCALE:
10th Floor
Drawn By:
DATE
MED
RDP
B1
NO.
A1
C
BUILDINGS A1, A2 & A3 - ATTIC AND ROOF PLAN - PLUMBING
SCALE: 1/8"=1'-0"
1
H
T
R
O
N
Issued for Permit & Construction
BUILDING TYPE B -
Sheet Number:
P2.20
PLAN - PLUMBING
FAMILY & GRADUATE HOUSING
Construction US
Issued for Code Review
A3 Balfour Beatty
University of Iowa
UNDER FLOOR
KEY SITE PLAN
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
ASI-003
Iowa City, IA 52246
Dallas, TX 75201
N.T.S.Project Number:
A2
B2
2012042
Checked By:
08.14.201306.07.201305.03.2013
SCALE:
10th Floor
Drawn By:
DATE
MED
RDP
B1
NO.
A1
C
BUILDINGS B1 & B2 - UNDER FLOOR PLAN - PLUMBING
SCALE: 1/8"=1'-0"
1
H
BLD. B2
T
R
O
N
BLD. B1
H
T
R
O
N
Issued for Permit & Construction
Sheet Number:
P2.21
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
ASI-003ASI-002
N.T.S.
Checked By:
08.14.201308.01.201306.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
192
H
T
R
N
H
T
R
N
191
Issued for Permit & Construction
Sheet Number:
P2.22
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
ASI-003ASI-002
N.T.S.
Checked By:
08.14.201308.01.201306.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
UNIT X15
X00E
X92
X41
X40
X00A
H
T
R
N
H
T
R
O
N
X00A
X91
UP
Issued for Permit & Construction
BUILDING TYPE B -
Sheet Number:
P2.23
FAMILY & GRADUATE HOUSING
Construction US
A3
Balfour Beatty
University of Iowa
KEY SITE PLAN ROOF PLAN -
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
ASI-003
Iowa City, IA 52246
PLUMBING
Dallas, TX 75201
N.T.S.Project Number:
A2
B2
2012042
Checked By:
08.14.201306.07.2013
SCALE:
10th Floor
Drawn By:
DATE
MED
RDP
B1
NO.
A1
C
BUILDINGS B1 & B2 - ATTIC AND ROOF PLAN - PLUMBING
SCALE: 1/8"=1'-0"
1
H BLD. B2
T
R
O
N
BLD. B1
H
T
R
O
N
Issued for Permit & Construction
Sheet Number:
BULDING TYPE C -P2.30
PLAN - PLUMBING
FAMILY & GRADUATE HOUSING
Construction US
Issued for Code Review
A3 Balfour Beatty
University of Iowa
UNDER FLOOR
KEY SITE PLAN
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
Dallas, TX 75201
N.T.S.Project Number:
A2
B2
2012042
Checked By:
06.07.201305.03.2013
SCALE:
10th Floor
Drawn By:
DATE
MED
RDP
B1
NO.
A1
C
BULDING TYPE C - UNDER FLOOR PLAN - PLUMBING
SCALE: 1/4"=1'-0"
1
H
T
R
O
N
Issued for Permit & Construction
Sheet Number:
P2.31
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
N.T.S.
Checked By:
06.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
PURPOSE
MULTI-
101
PANTRY
101A
MEDIA ROOM
PURPOSE
MULTI-
101B
ELECTRICAL
STORAGE
DATA/
143
142
VESTIBULE
ENTRY
100
CORRIDOR
100B
VESTIBULE /
VENDING
ENTRY
100D
RECEPTION
100A
MAIL
100E
FITNESS
105
OFFICE
102
H
T
R
N
OFFICE
103
RESTROOM
WOMEN'S
107
LAUNDRY
WORK ROOM
106
104
RESTROOM
MEN'S
108
MAINTENANCE
141
MECHANICAL
140
Issued for Permit & Construction
Sheet Number:
P2.32
FAMILY & GRADUATE HOUSING
Construction US
A3
Balfour Beatty
University of Iowa
KEY SITE PLAN ROOF PLAN -
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
PLUMBING
Dallas, TX 75201 BUILDING
TYPE C -
N.T.S.Project Number:
A2
B2
2012042
Checked By:
06.07.2013
SCALE:
10th Floor
Drawn By:
DATE
MED
RDP
B1
NO.
A1
C
BUILDING TYPE C - ROOF PLAN - PLUMBING
SCALE: 1/4"=1'-0"
1
H
T
R
O
N
Issued for Permit & Construction
Sheet Number:
P3.10
Construction US
Issued for Code Review
Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
2013 Solomon Cordwell Buenz
ASI-007
N.T.S.
Checked By:
10.21.201306.07.201305.03.2013
SCALE:
Drawn By:
DATE
NO.
Issued for Permit & Construction
Sheet Number:
P4.10
FAMILY & GRADUATE HOUSING
Construction US
Issued for Code Review
A3 Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
PLUMBING
Dallas, TX 75201
N.T.S.Project Number:
A2 DETAILS
B2
2012042
Checked By:
06.07.201305.03.2013
SCALE:
10th Floor
Drawn By:
DATE
MED
RDP
B1
NO.
A1
C
AIR/VENT THRU ROOF (SHINGLE ROOF)
VENT THROUGH METAL ROOF
CONCENTRIC COMBUSTION
ISLAND SINK VENT DETAIL
NO SCALE
NO SCALENO SCALE
12
48
DETAIL (APARTMENTS)
PEX MANIFOLD DETAIL
VENT PIPE FLASHING
GAS WATER HEATER
NO SCALENO SCALENO SCALE
11
37
RATED FIRE BARRIER PENETRATION
PIPE UNDER FOOTING DETAIL
PIPE SUPPORT DETAIL
NO SCALENO SCALE
NO SCALE
26
10
PIPE THROUGH NON-FIRE RATED WALL
UNDERGROUND TUBING TO ISLAND FIXTURES
DOMESTIC WATER ENTRANCE
NO SCALENO SCALE
15
NO SCALE
9
Issued for Permit & Construction
Sheet Number:
P5.10
FAMILY & GRADUATE HOUSING
Construction USAND SCHEDULES
Issued for Code Review
MATERIAL LIST
A3 Balfour Beatty
University of Iowa
KEY SITE PLAN
DESCRIPTION
3100 McKinnon Street
2013 Solomon Cordwell Buenz
101 Hawkeye Court
ASI-007
Iowa City, IA 52246
PLUMBING
Dallas, TX 75201
N.T.S.Project Number:
A2
B2
2012042
Checked By:
10.21.201306.07.201305.03.2013
SCALE:
10th Floor
Drawn By:
DATE
MED
RDP
B1
NO.
A1
C
WATER HEATER PIPING/MOUNTING DETAIL
1/2" CW AND HW APPLIES ONLY TO THE FINAL VERTICAL RISE-DROP TO EACH FIXTURE. BRANCH PIPING TO VERTICAL RISE-DROP
NO SCALE
SIZES SHOWN ARE MINIMUMS. SIZES SHOWN ON THE DRAWING THAT ARE LARGER THAN THE SIZES LISTED IN THE SCHEDULE
3
NOTE 1 & 2NOTE 1 & 2NOTE 1 & 2
REMARKS
GAS MANIFOLD PIPING CONNECTION DETAIL
PLUMBING FIXTURE ROUGH-IN SCHEDULE
NOTE 1NOTE 2NOTE 2
EXTERIOR PIPE CHASE WALL DETAIL
----------
(NOTE 3)
1 1/2"1 1/4"1 1/2"1 1/2"1 1/4"1 1/2"1 1/4"1 1/2"1 1/4"1 1/4"1 1/2"1 1/2"
VENT
2"2"2"
-
SANITARYSANITARY RISER UP IN WALL TO FIXTURE SHALL BE A MINIMUM OF 2".
(NOTE 3)
1 1/4"1 1/2"1 1/2"1 1/2"
4"4"2"3"3"2"2"2"2"3"4"
-
SHALL BE A MINIMUM OF 3/4" INCH UNLESS NOTED OTHERWISE.
DOMESTIC(NOTE 3)
H.W.
3/4"3/4"3/4"3/4"
1/2"1/2"1/2"1/2"
--------
DOMESTIC(NOTE 3)
C.W.
1/2"3/4"1/2"3/4"3/4"1/2"3/4"1/2"1/2"1/2"3/4"3/4"
1"
---
SHALL DICTATE THE ROUGH-IN SIZE.
WATER CLOSET (FLUSH VALVE)
KITCHEN SINK (COMM.CENTER)
WATER CLOSET (TANK TYPE)
KITCHEN SINK (RES. UNITS)
ELECTRIC WATER COOLER
WASHING MACH. FIXTUREFLOOR DRAIN/FLOOR SINKFLOOR DRAIN/FLOOR SINKFLOOR DRAIN/FLOOR SINK
FIXTURE DESCRIPTION
SERVICE SINK
MOP BASIN
LAVATORYHOSE BIBB
BATHTUB
SHOWER
URINAL
NOTES:
1.2.3.
NO SCALE
NO SCALE
2
1
Sheet Number:
S6.00
06.07.2013Issued for Permit & Construction
FAMILY & GRADUATE HOUSING
NO.DATEDESCRIPTION
WOOD DETAILS
05.03.2013Issued for Code Review
University of Iowa
Construction US
3100 McKinnon Street
Balfour Beatty
2013 Solomon Cordwell Buenz
101 Hawkeye Court
Iowa City, IA 52246
108.29.2013ASI-004
Dallas, TX 75201
Project Number:
2012042
Checked By:
10th Floor
Drawn By:
JOHFOUHEAHEI
TRUSSES WITH HGA10 SIMPSON
CONNECTOR (OR EQUIVALENT)
TYPICAL TRUSS BEARING AT EXTERIOR CAL TO BE REINFORCED AND
FASTEN TO BLOCKING AND
EAR WALL BELOW AND TO
2x6 OUTRIGGER SHALL BE
DESIGN MEMBER TO RESISTS TO BE CONNECTED TO TRUSS
OUTRIGGER WITH (4) 16dF TRUSS FROM THE ROOFTO DESIGN TOP CHORD OF
2x4 BLOCKING BETWEEN
2x4 BRACING @ 4'-0" OC
STAIR SECTION AT EXTERIOR WALL DES MOINES, IOWA 50322
L NOTES FOR WIND
1
ROOF SHEATHING -
12.0768.00
SIMPSON SDS SCREWS 1/4"x1/2" INTO00 LBS UPLIFT AT 2x8
2882 106th STREET
HGA10 SIMPSON CONNECTOR (OR
ROOF TRUSS -
EQUIVALENT) @4'-0" OC WITH (4)
SCREWS 1/4"x3" INTO TOP PLATE
SECTION AT EXTERIOR WALL PROJECT #
EL (REF PLAN)
TRUSS AND (4) SIMPSON SDS
FINISH FLOOR JOIST BEARING AT INTERIOR WALL
REF PLANREF PLAN
GYPCRETE TOPPING -
HEADER AT
NOTE 3
S6.00
FLOOR SHEATHING -ERVICE).
NAILSGYPCRETE TOPPING -
WHEN STUDS DO5
L AS SHOWN.
AN FOR LOADS.FLOOR SHEATHING -
TM
27/S6.01 FOR
COMPONENTS AND CLADDING WIND LOADS. REFER TO GENERA
STAIR
PROVIDE 2x6 TOP CHORD FOR CONNECTION OF OUTRIGGER.
WOOD TRUSS -
TRUSS MANUFACTURER IS TO DESIGN TRUSS TO BEAR ON SH
E WALL LOAD
PARAMETERS. TRUSS DESIGNER IS TO DETERMINE IF VERTI
TRANSFER 150 PLF (SERVICE WIND) LOAD ALONG LENGTH OWITH SIMPSON LUS26 JOIST HANGER. TRUSS DESIGNER IS
PROVIDE VERTICALS AT 16" OC AT THE GABLE TRUSS AND
DOUBLE TOP
TRUSS FOR 50 LBS UPLIFT LOAD AT 2x6 OUTRIGGER AND 5WOOD JOIST -
OUTRIGGER. UPLIFT LOADS INDICATED ARE FOR (DL+SL S
REF PLANREF PLANREF PLANTOE NAIL WITH (3) 16d NAILS AND THE 2x8 OUTRIGGER I
REF PLANREF PLANREF PLAN
ROOF TRUSS SECTION
PLATE
AT SIMILAR PROVIDE HORIZONTAL GIRTS IN EXTERIOR WAL
2x BLOCKING AT FLOOR
STUD WALL - REF PLANRAILING NOT SHOWN FOR CLARITY -REFER TO 5/S6.00 AND
PROVIDE SQUASH BLOCKING BETWEEN SILL AND TOP PLATE
S
ABOVE AND HALF THE JOIST FRAMING SHOWN. REFER TO PL
JOISTS NOT ALIGNED
NOT SIT ON TRUSS. ALIGN STUD FRAMING BETWEEN LEVEL
DOUBLE TOP PLATE
DESIGN THE VERTICALS IN THE END OF THE TRUSS FOR TH
WITH WALL STUDS
DEPTH 'D'
SHEATHING TO THE SHEAR WALL BELOW.
EXTERIOR WALL WITH (2) 16d
2x10 LEDGER ATTACHED TO
PROVIDE SIMPSON H10
NOTE 1LANDING. SHEATHING TO
2x10 FRAMING AT 16" OC
NAILS AT EACH EXTERIORWALL STUD. INSTALL AT 3
INTERIOR SHEATHING -
AND 2
MATCH TYPICAL FLOOR
(OR EQUIVALENT TIE
AT EACH TRUSS)
JOIST HANGER, TYPAT INTERMEDIATE
SIDES OF LANDING
SIMPSON LUS28 (
OR EQUIVALENT)
S6.01
TOP OF FLOOR
12
HEADER -
REF PLAN
"2
REF ARCH
D
BEYOND
PROVIDE DETAILING.
REF PLAN12
CONNECTION DETAILS.
1
4
D
DOUBLE TOP PLATE
WALL SHEATHING - 3/4" = 1'-0"
BLOCK AT EACH STUD
PROVIDE 2x6 SQUASH
3/4" = 1'-0"
:
ALIGNED WITH STUD
WALL SHEATHING -
WALL SHEATHING -
FLOOR JOISTS NOT
BETWEEN OUTRIGGERSTRUSS BEARINGNOTES
UNDER SILL PLATE
EL (REF S6.02)
CONTINUOUS 2x6
2x BLOCKING AT
BEARING WALL
PROVIDE BLOCKING
1.2.3.
3/4" = 1'-0"
3/4" PLYWOODBLOCKING AT
WALL STUD -
RIBBON, TYPREF PLAN:
NOTES
SILL PLATE
2x6 OUTRIGGER
3/4" = 1'-0"
LAP OVER
AT 24" OC, UNOREF PLAN
REF PLANREF PLAN
(NOTE 2)
NOTES:
2x10 FASCIA
1.2.
WALLS
JOIST
3/4" = 1'-0"
1" MAX
1.2.
BOARD
1
3/4" PLYWOOD AT LANDING
PROVIDE (3) 2x10 MINIMUM
1
WIND GIRT ALL EXTERIOR
AT FLOOR ELEVATION AS
1
BETWEEN TOP CHORD OFEXTERIOR STUD WALL -
P ALONG SOME CORRIDORS -
WALLS AROUND STAIR
PROVIDE 2X4 BLOCKING
NG SHALL BE 2X4 SPANNING
SS BEARING ON CORRIDOR
DOUBLE SILL PLATEDOUBLE TOP PLATE
WALL SHEATHING -
6' AWAY. PLACE SWAY
WALL SHEATHING -
ROOF SHEATHING -
2x12 STAIR
STRINGER
EL (REF PLAN)
EL (REF S6.02)
SECTION A - A
1
TRUSS BRG
REF PLANREF PLAN
B/TRUSS
REF PLAN
REF PLAN
TRUSS BEARING AT INTERIOR
TRUSS
2"WOOD STAIR DETAIL
REFER TO ARCHITECTURAL DRAWINGS FOR STAIRNOT ALIGNED WITH STUD
DRAFT STOP SHEATHING2x BLOCKING AT JOISTS
REFER TO ARCHITECTURAL FOR RAILING SIZES
FASCIA
DOUBLE TOP PLATEBOARD
GYPCRETE TOPPING -
DIAMETER THROUGH BOLTS WITHTRUSS VERTICALSFLOOR SHEATHING -
OR SWAY BRACING
2X6 AT 6'-0"(MAX)BETWEEN TOP CHORD OF JOIST TO BOTTOM CHORD OF TRUSS
BETWEEN TRUSS
FLOOR SHEATHING -
REF ARCH DWGS
WALL WHEN DRAFT SHEATHING IS NOT SHOWN. SWAY BRACI
DOUBLE TOP PLATE
PROVIDE SWAY(CROSS) BRACING ON VERTICAL WEBS OF TRU
(NOTES 1 AND 2)
WEB STIFFENER AT
REF ARCH DWGS FOR LOCATIONS AND MORE INFORMATION.
ROUND HEADS AT TREAD SIDE
SHEATHING IS TO EXTEND TO ROOF TO PROVIDE DRAFT STO
1/4" BENT PLATE WITH (4) 1/2"
2X6 BETWEEN
SHEATHING -
WOOD TRUSS -
WOOD I-JOIST -
VERTICALS
JOIST HANGER
4"EL (REF PLAN)WOOD BEAM -
FINISH FLOOR
SECTION AT WOOD BEAM
1 1/2"
GEOMETRY AND DIMENSIONING.
REF PLANREF PLAN
WALLS
REF PLANREF PLANREF PLANREF PLAN
THRU-FLOOR HOLD-DOWN S.
POST
END
CONFIRM FLOOR TRUSS LAYOUT WITH SHEAR WALL END POST
CANOPY JOIST -
FLOOR TRUSSES CAN BE SHIFTED A MAXIMUM 6" TO AVOID
POSTS. CONFIRM SPACING WITH TRUSS MANUFACTURER.
2"BOARD - REF
S6.00
2x10 FASCIA
4"
6
REF PLAN
1"
AA
AND SPACING.
BRACING EVERY 40' ALONG ROOF.
PLAN
1 1/4" PIPE RAILING -
3/4" = 1'-0"
HEADER - REF PLAN
REF ARCH DWGS4" MAX
:
SLOPED HANGER
NOTES
OR EQUIVALENT
ROOF SHEATHING -
SHEATHING -
EL (REF PLAN)
4"1 1/2"FINISH FLOOR
SIMPSON LSC
1.2.
AND RECESSED AT OUTSIDE FACE.
REF PLAN
WALL.
3/161/2"Ø THRU BOLTS CONTERSUNK
INTERIOR BEARING WALL -
12
AND CROSS BRACING AS
TRUSS MANUFACTURER
REF PLAN
H2A (OR EQUIVALENT)
TO PROVIDE BRIDGING
REFER TO 28/S6.1 AT TRUS JOIST BEARING ON EXTERIOR
TIE AT EACH TRUSSBEARING LOCATION
PROVIDE SIMPSON
4
3/4" = 1'-0"
:
LEDGER BOARD 2x10
ROOF TRUSS -
NOTES
SCHEDULE FOR TYPE
UNDER SILL PLATE
QUANTITY OF SHEAR
PANEL 'H' CLIPS @ ROOF ONLYCOILED STRAP - REF
TRELLIS B BUILDING
(2) @ EACH JOIST
BLOCKING - MATCH
REF PLAN(OR EQUIVALENT)
REQUIRED
3/4" = 1'-0"
1.2.
REF PLANREF PLAN
WALL END POSTSSHEAR WALL END
INTO EACH POST
AND FASTENERS
3/4" PLYWOODSIMPSON LUS28
SCHEDULE, TYP
JOIST HANGER
WOOD JOIST -
NAILS AT EACH JOIST -
REF GENERAL NOTESPOST - REF
(TYPICAL)
3/4" = 1'-0"REF PLAN
INTERIOR SUPPORTSUPPORTED PANEL
NOTES:
EL (REF PLAN)
T/SHEATHING
PANEL EDGES
1.
PERIMETER
2x4 BLOCKING BETWEEN
ROOF SHEATHING -
SHEATHING LAYOUT AND FASTENING
CONNECTOR (OR
SIMPSON SDS SCREWS 1/4"x1/2" INTO
HGA10 SIMPSON
ROOF TRUSS -TRUSSES WITH
2x4 BRACING @
EQUIVALENT)
HGA10 SIMPSON CONNECTOR (OR
SCREWS 1/4"x3" INTO TOP PLATE
REF PLANREF PLAN
EQUIVALENT) @ 4'-0" WITH (4)
TRUSS AND (4) SIMPSON SDS
4'-0" OC
IGN MEMBERS TO
ALONG LENGTH
HORD OF
JOINTS (TYPICAL)
SECTION AT EXTERIOR WALL
WOOD JOISTS OREL (REF PLAN)
1" = 1'-0" GENERAL
STAGGER PANEL
EAR WALL
FINISH FLOORTERMINE IF
ROOF RAFTERS
NOTES
IM JOIST OR
BELOW.
BLOCKING AT 4'-0" OC
REF TYPICAL TRUSS
DOUBLE TOP PLATE
HEADER - REF SCHEDULE
2x6 BLOCKING @ 4'-0" OC
1.
STUD WALL TO HEADER
JOIST - REF PLAN
BEARING DETAIL
NG.
FASTEN BOTTOM CHORD OF LOWER ROOF TRUSS TO BOTTOM C
FLOOR SHEATHING -
OF TRUSS FROM THE ROOF SHEATHING TO THE SHEAR WALL
DOUBLE TOP PLATE EXTERIOR WALL HEADER RESIST COMPONENTS AND CLADDING WIND LOADS. REFER TO
TRUSS MANUFACTURER IS TO DESIGN TRUSS TO BEAR ON SH
T/ROUGH OPENINGVERTICALS ARE TO BE REINFORCED AND PROVIDED DETAILI
NOTES FOR WIND PARAMETERS. TRUSS DESIGNER IS TO DE
BELOW AND TO TRANSFER 150 PLF (SERVICE WIND) LOADS
RIM BOARD
PROVIDE VERTICALS AT 16" AT THE GABLE TRUSS AND DES
AT SIM, WOOD JOIST IS TRUS JOIST. TIMBERSTRAN LSL R
WITH JOIST BEARING EACH SIDE
EL (REF ARCH)
WOOD JOIST -
EL (REF PLAN)
STUD WALL -
FINISH FLOOR
WOOD TRUSS - REF PLANINTERIOR BEARING WALL
REF PLANREF PLANREF PLAN
GYPCRETE TOPPING -
FLOOR SHEATHING -
EEN LEVELS.
DOUBLE TOP PLATE
NOTE 1
EL (REF PLAN)
FINISH FLOOR
AND 2
LF OF THETO PLAN
SHEATHING -WHEN
MAIN ROOF WITH (2) 16d NAILS AT 24" OC.
S6.01
- REF PLAN12
REF ARCH
REF PLANREF PLAN
WALL LOAD ABOVE AND THE JOIST FRAMING SHOWN. REFER PROVIDE SQUASH BLOCKING BETWEEN SILL AND TOP PLATE
ROOF AND FLOOR
DESIGN THE VERTICALS IN THE END OF THE TRUSS FOR HA
STUDS DO NOT SIT ON TRUSS. ALIGN STUD FRAMING BETW
EQUIVALENT. REFER TO 28/S6.1
SECTION AT
REF PLAN
WITH BOTTOM OF
REF ARCH. REF -
JOIST - REF PLAN
BOARD ALIGNED
TYPICAL SECTION
METAL DECK -CANOPY JOISTCANOPY JOIST
DOUBLE TOP PLATE
INTO DOUBLE
DECORATIVE
2x10 FASCIA
ROOF TRUSS - REF PLAN
TRUSS BEARING
UNDER SILL PLATE
EL (REF S6.02)
NOTE 1
ROOF SHEATHING -
PROVIDE BLOCKING
WALL SHEATHING -
3/4" = 1'-0" 3/4" = 1'-0"
3/4" PLYWOOD
SHEATHING -
NOTES:
:
2x6 OUTRIGGER
NOTES
SILL PLATE
RIM JOIST
REF PLAN
OUTRIGGERS
MATCH NUMBER OF UPPER
1/2" = 1'-0"2x10 FASCIA
1.
1.2.3.
POST STUDS - REF PLANWALLBETWEENREF PLANREF PLAN
AT 24" OC
(NOTE 3)
PROVIDE BLOCKING TO
TOP CHORD BEARINGBOARD
FLOOR TRUSS - REF
PLAN AND 17/S6.00
HANGER AT EACH JOIST
2x BLOCKING AT FLOOR
JOISTS NOT ALIGNED
EL (REF PLAN)
SIMPSON LUS28 (OR2x6 CONT BLOCKING
EQUIVALENT) JOISTROOF SHEATHING -
FINISH FLOOR2x6 SQUASH BLOCK
FOR LOADS.
UNDER SILL PLATECONTINUOUS 2x10
WITH STUD WALLS
BLOCKING WITHAT WALL STUDS
(4) 16d NAILS @
3/4" = 1'-0"
3/4" PLYWOOD
FASTENED TO
HEADER -
REF PLAN
JOIST - REFNOTES:
LEDGER AT OPEN TRELLIS -
SILL PLATE
HANGER (OR EQUIVALENT)
REF PLAN
(NOTE 2)
(18) 16d NAILS (BELOW 2ND
2x6 JAMB STUD ATTACHEDWALL AND SHEATHING -
CONTINUOUS MEMBERS
TO BUILT UP POST WITH24" OC CANOPY AT BUILDING B
1.2.
PLANSIMPSON LUS28 JOIST
PROVIDE 2x6 SQUASH
BLOCKING TO MATCH
RIM JOIST BETWEEN
UNDER SILL PLATE
DOUBLE TOP PLATE
REF PLAN
S6.00UNDER SILL PLATE
BUILT UP POST -
TOP AND BOTTOM
12X6 CONTINUOUS
17
BLOCK AT JOIST
3/4" PLYWOOD
INTERIOR BEARING WALL
AT EACH JOIST
WOOD JOIST -
3/4" PLYWOOD
1FINISH. PROVIDE SHIM AS REQUIRED TO CREATE
FLOOR ONLY)1
REF 15/S6.00
DECK WILL BE EXPOSED AT TOP AND BOTTOM.
DECK MUST BE CAPABLE OF A CAPACITY OF 55
REF PLAN
REF PLANSILL PLATE
PSF. PROVIDE CLOSURES AT EACH MEMBER.
DECK SLOPE AS SHOWN ON ARCHITECTURAL
ALCOVE AND UTILITY CLOSET
REF PLAN
REFERENCE ARCH DWGS FOR REQUIRED
DRAWINGS. REFER TO ARCHITECTURAL
DRAWINGS FOR MORE INFORMATION.
ROOF TRUSS SECTION
CONTINUOUS HEADER AT
REF ARCH DRAWINGS
2x6 AT EACH TRUSS -
SHOULDER STUDS -
FOR ROOF PITCH
ROOF TRUSS -
REF SCHEDULE
ABOVE UTILITY
CLOSET DOOR
12
2x6 HEADER
REF PLAN
SECTION AT
KING AND
EL (REF PLAN)
FINISH FLOOR
4
FLOOR TRUSS PARALLEL TO WALL
1" = 1'-0"
:
NOTES
GYPCRETE TOPPING - REF PLAN
BLOCKING TO PROVIDE SUPPORT
HEADER -
REF PLAN
1.
2x6 KICKER AT 4'-0" FASTENED
BRIDGING AND ATTACHMENT
FLOOR TRUSS -
TO BE PROVIDED BY TRUSS
TO BLOCKING AND TRUSS
FOR CONTINUOUS CANOPY
WOOD TRUSS - REF PLAN
3/4" = 1'-0"
SILL PLATE
GYPCRETE TOPPING -EAR WALL
REF PLANFLOOR SHEATHING -
FLOOR SHEATHING -
DOUBLE TOP PLATE
AT EACH
STOP.
RUSS
3/4" = 1'-0"
RUSS.
UNDER SILL PLATE
WITH (3) 16d NAILS
JB28 JOIST HANGER
T/ROUGH OPENING
WALL - REF PLAN
MANUFACTURER
WOOD JOIST -
FOR
DOUBLE JOIST -
EL (REF PLAN)
3/4" PLYWOOD
BELOW AND TO TRANSFER SHEAR LOADS ALONG LENGTH OF TBLOCKING AND CONTINUOUS SHEATHING TO PROVIDE DRAFT
EL (REF ARCH)
FINISH FLOOR
TRUSS MANUFACTURER TO DESIGN TRUSS TO TRANSFER THE
EL (REF PLAN)
TRUSS MANUFACTURER IS TO DESIGN TRUSS TO BEAR ON SHFOLLOWING SERVICE WIND LOADS ALONG FULL LENGTH OF T
SHEAR WALLS ALIGNED WITH THIS TRUSS HAVE END POSTS
FROM WALL TO WALL. POSITION TRUSS ON WALL TO ALLOW
FINISH FLOOR
.
REF PLANREF PLAN
REF PLANREF PLANEND OF WALL - REFER TO 4/S6.01 FOR MORE INFORMATION
4
3/4" = 1'-0"
REF PLAN
MEMBER
12
ROOF OR FLOOR TRUSS -
PROVIDE SIMPSON H10 (ORTRUSS BEARING LOCATION
EQUIVALENT) TIE AT EACH
PROVIDE 2X4 BLOCKING
1
BETWEEN TRUSSESDOUBLE TOP PLATE
WALL SHEATHING -
2x10 BLOCKING @ 4'-0" OC
TRUSS BEARING
EL (REF PLAN)
SINGLE PLATE
EL (REF PLAN)
FINISH FLOOREL (REF ARCH)
EL (REF S6.02)
DOUBLE TOP PLATE
REF PLAN
2x10 FASCIA
REF PLAN
T/FASCIA
B/TRUSS
WOOD JOIST -
BOARD
ON TRUSS GIRDER
ROOF TRUSSES - REF
GYPCRETE TOPPING -
300 PLF420 PLFROOF SHEATHING -REF PLAN
FLOOR SHEATHING -
TRUSS BEARING TRUSS BEARING
1
GIRDER TRUSS
EL (REF PLAN)
HEADER DETAIL
REF PLAN
SILL PLATERIM BOARD
3RD FLOOR:2ND FLOOR:
REF PLANREF PLAN
AND ANCHOR - REF SHEARAND ANCHOR - REF SHEARAND ANCHOR - REF SHEAR
BEARING WALL
SHEAR WALL HOLDDOWNSHEAR WALL HOLDDOWNSHEAR WALL HOLDDOWN
PLAN
3/4" = 1'-0"
WALL SCHEDULE, TYP
HEADER BEAM - REF PLAN
:
AND HEADER SCHEDULE
SHOULDER STUDS - REF
POSTS - REF SHEARPOSTS - REF SHEAR
NOTES
PROVIDE 2x6 SQUASH
2x6 CONTINUOUS TOP
SHEAR WALL ENDSHEAR WALL END
SECTION AT WALL SCHEDULEWALL SCHEDULEWALL SCHEDULEWALL SCHEDULE
DOUBLE TOP PLATEBETWEEN TRUSSES
HEADER SCHEDULE
1.2.
SHEATHING - REF
AT EACH KICKER
BLOCK @ 16" OCWALL STUD AND
LOCATION DETAILS WHERE SHEAR WALLS ENDS SHARE END POST
2x6 BLOCKING
AND BOTTOM
SILL PLATE
3/4" = 1'-0"
USE THE SHEAR END POST WITH THE
PLAN
CORNER INSTALLATION
3/4" = 1'-0"
MID-WALL INSTALLATION
GREATEST AMOUNT OF STUDS.
3/4" = 1'-0"
PERPENDICULAR TOWALL INSTALLATION
HOLD DOWN
UNDER SILL PLATE
10"
3/4" PLYWOOD
10"
SHEATHING -
PLYWOOD
REF PLAN
3/4" = 1'-0"
:
- REF HEADER
NOTES
(KING) STUDS
FULL HEIGHT
DOUBLE TOPINTO TRUSS AND (4) SIMPSON SDS
HGA10 SIMPSON CONNECTOR (ORSTAGGERED
NIM
STUD WALL
SCREWS 1/4"x3" INTO TOP PLATE
SCHEDULE1SIMPSON SDS SCREWS 1/4"x1/2"
1.
POSTS - REF SHEAR
EQUIVALENT) @ 4'-0" WITH (4)
WHEN STUDS DO
"01
SHEAR WALL END
PLATE
WALL SCHEDULE
REF PLAN AND SCHEDULE
EL (REF PLAN)
ROOF TRUSS - REF PLAN
FINISH FLOOR
10"
WITH JOIST BEARING EACH SIDE
GYPCRETE TOPPING -
EL (REF PLAN)0' - 8 1/2"
FLOOR SHEATHING -
FINISH FLOOR1'-0" MAX
(NOTE 1)
WOOD TRUSS - REF PLAN
GYPCRETE TOPPING -
EAR WALL
FLOOR SHEATHING -
WOOD TRUSS -SHEAR WALL -
SECTION AT SHEAR WALL
WOOD TRUSS -PROVIDE SQUASH BLOCKING BETWEEN SILL AND TOP PLATE OF
AT EACHTRUSS MANUFACTURER TO DESIGN TRUSS TO BEAR ON SHEAR
STOP.LOADS ALONG LENGTH OF TRUSS FROM THE ROOF SHEATHING
UNDER SILL PLATE
EL (REF PLAN)RUSSS
RUSS.
DOUBLE TOP
P
FINISH FLOORWALL STUD AND SHEATHING -
NOT SIT ON TRUSS. ALIGN STUD FRAMING BETWEEN LEVEL
TO THE SHEAR WALL BELOW. POSITION TRUSS ON ONE SIDESHEATHING IS TO EXTEND TO ROOF TO PROVIDE DRAFT STO
2x6 CONTINUOUS BLOCKING(NOTE 1)
REF PLANREF PLANREF PLAN
FOR
FLOOR SHEATHING -3/4" PLYWOOD
WALL BELOW AND TO TRANSFER 150 PLF (SERVICE WIND)
REF PLANSIMPSON LUS28 HANGER
BELOW AND TO TRANSFER SHEAR LOADS ALONG LENGTH OF TBLOCKING AND CONTINUOUS SHEATHING TO PROVIDE DRAFT
TRUSS MANUFACTURER TO DESIGN TRUSS TO TRANSFER THE
GYPCRETE TOPPING -
TRUSS MANUFACTURER IS TO DESIGN TRUSS TO BEAR ON SHFOLLOWING SERVICE WIND LOADS ALONG FULL LENGTH OF TPLATE
SHEAR WALLS ALIGNED WITH THIS TRUSS HAVE END POSTS SECTION AT HEADER
FROM WALL TO WALL. POSITION TRUSS ON WALL TO ALLOW
.
REF PLANREF PLAN
FLOOR SHEATHING -
AT SOME SHEAR WALLS - REFER TO ARCH DWGS FOR
END OF WALL - REFER TO 4/S6.01 FOR MORE INFORMATION
INTERIOR SHEAR WALL
SHEAR BOLTS -
DOUBLE TOP PLATE
REF SCHEDULE
WALL FOR ATTACHMENT OF CONNECTOR SHOWN.
(OR EQUIVALENT
TOP AND BOTTOM
@ EACH JOIST)
EL (REF PLAN)WOOD JOIST -
REF PLAN
REF SCHEDULE
2" MIN INTERIOR WOOD BEAM
FINISH FLOOR
TYPICAL SECTION AT
HEADER -TYPICAL SECTION AT
REF PLANREF PLANREF PLANREF PLAN
LOCATIONS AND MORE INFORMATION.
2x4 SQUASH
BLOCK AT
TYPICAL SECTION
24" OC
OF WALL ANDWOOD PLATE
SCHEDULE (NOTE 2)
ROOF SHEATHING -
T/ROUGH OPENING
300 PLF420 PLF
1
SHEATHING - REF
EL (REF ARCH)
3/4" = 1'-0"
BLOCK AT EACH STUDSIMPSON LUS28 HANGER
PROVIDE 2x6 SQUASH
HEADER - REF PLAN
WALL SHEATHING -REF PLAN 3/4" = 1'-0"
NOTES:
WOOD TRUSS ABOVE3RD FLOOR:2ND FLOOR:UNDER SILL PLATE
(OR EQUIVALENT) AT
CONTINUOUS 2x6
SHEAR WALL (NOTE:
DOUBLE TOP PLATEHEADER - REF PLAN
UNDER SILL PLATE
NOTES
SHEATHING - REF
BETWEEN FLOOR
3/4" PLYWOOD
WALL STUD AND 3/4" = 1'-0"
1.
RIBBON, TYP
TOPPING - REF
3/4" PLYWOOD:1.2.WOOD JOIST -
2x10 WITH (3) 3/4" = 1'-0" 3/4" = 1'-0"
TOP CHORDSCONTINUOUS
NOTES
REF PLAN
(NOTE 1)
EACH JOIST
SILL PLATE16d NAILS @
SCHEDULEGYPCRETE
SILL PLATE
1
REF PLAN
1.2.
WOOD JOIST -
16" OC
PLAN
1
REF PLAN
1)