HomeMy WebLinkAbout9/30/15 energy2015 Envelope Compliance Certificate Project Information 2012 IECC Energy Code: Johnson County Courthouse Secured Entrance Project Title: Iowa City, Iowa Location: 5a Climate Zone: Addition Project Type: 36% Vertical Glazing / Wall Area: Construction Site:Owner/Agent:Designer/Contractor: Building AreaFloor Area 1-Courthouse : Nonresidential725 Envelope Assemblies Assembly Proposed Gross AreaCavityCont.Budget U- U-Factor orR-ValueR-ValueFactor (a) Perimeter Roof 1: Other Roof, \[Bldg. Use 1 - Courthouse\] (b) 758------0.0220.027 Exterior Wall 2: Other Mass Wall, Heat capacity 21.0, \[Bldg. Use 1 - 435------0.0220.078 Courthouse\] (b) Window 1: Metal Frame with Thermal Break:Fixed, Perf. Type: Energy 171------0.6500.380 code default, Double Pane, Tinted , SHGC 0.60, PF 0.33, \[Bldg. Use 1 - Courthouse\] Exterior Wall 2: Other Exterior Wall, Heat capacity 21.0, \[Bldg. Use 1 - 273------0.0220.064 Courthouse\] (b) Door 1: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Type: 84------0.8000.770 Energy code default, Double Pane, Tinted , SHGC 0.60, PF 0.33, \[Bldg. Use 1 - Courthouse\] Floor 1: Slab-On-Grade:Unheated, Horizontal with vertical >= 4 ft., 71---10.00.1820.441 \[Bldg. Use 1 - Courthouse\] (c) (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)'Other' components require supporting documentation for proposed U-factors. (c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope PASSES: Design 4% better than code Envelope Compliance Statement Interior Lighting Compliance Certificate Project Information 2012 IECC Energy Code: Johnson County Courthouse Secured Entrance Project Title: Addition Project Type: Construction Site:Owner/Agent:Designer/Contractor: Allowed Interior Lighting Power ABCD Area CategoryFloor AreaAllowedAllowed Watts (ft2)Watts / ft2(B X C) 1-Secure Entry Structure (Common Space Types:Atrium) (Ceiling Height 11 ft.)7200238 44A444 Total Allowed Watts =238 (a)Allowed watts per sq. ft. adjusted for ceiling height. Proposed Interior Lighting Power BCDE A Lamps/# ofFixture(C X D) Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast FixtureFixturesWatt. 1-Secure Entry Structure (Common Space Types:Atrium) (Ceiling Height 11 ft.) LED 1: Cree CR24: Other:2630180 LED 2: Exit Light: Other:2212 LED 3: Emergency Light: Other:2155 LED 4: Cooper XTOR5A Crosstour: Other:16742 229 Total Proposed Watts = Interior Lighting PASSES: Design 3% better than code Interior Lighting Compliance Statement Exterior Lighting Compliance Certificate Project Information 2012 IECC Energy Code: Johnson County Courthouse Secured Entrance Project Title: Addition Project Type: 4 (High activity metropolitan commercial district) Exterior Lighting Zone Construction Site:Owner/Agent:Designer/Contractor: Allowed Exterior Lighting Power ABCDE Area/Surface CategoryQuantityAllowedTradableAllowed Watts Watts / UnitWattage(B X C) West Wall (Illuminated length of facade wall or surface)47 ft5No235 N and S Entry Doors (Main entry)30Yes360 12 ft of door 360 Total Tradable Watts (a) = Total Allowed Watts =720 Total Allowed Supplemental Watts (b) =1300 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 1300 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power BCDE A Lamps/# ofFixture(C X D) Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast FixtureFixturesWatt. West Wall ( Illuminated length of facade wall or surface 47 ft): Non-tradable Wattage LED 1: Other:1650300 N and S Entry Doors ( Main entry 12 ft of door width): Tradable Wattage LED 2: Other:1450200 N&S Walls ( Illuminated length of facade wall or surface 25 ft): Non-tradable Wattage 200 Total Tradable Proposed Watts = Exterior Lighting PASSES: Design 87% better than code Exterior Lighting Compliance Statement Mechanical Compliance Certificate Project Information 2012 IECC Energy Code: Johnson County Courthouse Secured Entrance Project Title: Iowa City, Iowa Location: 5a Climate Zone: Addition Project Type: Construction Site:Owner/Agent:Designer/Contractor: Mechanical Systems List QuantitySystem Type & Description 1HVAC System 1 (Single Zone): Heating: 1 each - Duct Furnace, Gas, Capacity = 60000 kBtu/h Proposed Efficiency = 95.50% Ec, Required Efficiency = 80.00% Ec Cooling: 1 each - Split System, Capacity = 36000 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 14.50 EER, Required Efficiency = 9.50 EER Fan System: None Mechanical Compliance Statement