HomeMy WebLinkAbout230 Kenneth energy auditREScheck Software Version 4.6.4
Compliance Certificate
Project Lot 12 Lindemann
Energy Code:2012 IECC
Location:Iowa City, Iowa
Construction Type:Single-family
Project Type:New Construction
Orientation:Bldg. faces 270 deg. from North
Conditioned Floor Area: 2,634 ft2
Glazing Area 10%
Climate Zone: 5 (6227 HDD)
Permit Date: Sep 2019
Construction Site:
230 Kenneth Dr.
Iowa City, IA
Owner/Agent:
Jesse Allen
Allen Homes
530-8238
Designer/Contractor:
Michael Untrauer
Untrauer Drafting Service, Inc.
2260 Shropshire Circle
Coralville, IA 52241
319 430-0760
untrauer@gmail.com
Permit Number:
Compliance: Passes using UA trade-off
5.1% Better Than Code Maximum UA: 314 Your UA: 298
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-ValueU-Factor UA
Ceiling: Flat Ceiling or Scissor Truss 1,313 50.0 0.0 0.026 34
Exterior Wall 1: Wood Frame, 16" o.c.
Orientation: Front
594 19.0 0.0 0.060 28
Window 1: Vinyl Frame:Double Pane with Low-E
Orientation: Front
82 0.300 25
Door 1: Solid
Orientation: Front
40 0.150 6
Wall 2: Wood Frame, 16" o.c.
Orientation: Back
952 19.0 0.0 0.060 47
Window 2: Vinyl Frame:Double Pane with Low-E
Orientation: Back
161 0.300 48
Wall 3: Wood Frame, 16" o.c.
Orientation: Left side
633 19.0 0.0 0.060 36
Window 3: Vinyl Frame:Double Pane with Low-E
Orientation: Left side
25 0.300 8
Wall 4: Wood Frame, 16" o.c.
Orientation: Right side
603 28.0 0.0 0.050 30
Basement Wall 1: Solid Concrete or Masonry
Orientation: Front
Wall height: 8.0'
Depth below grade: 7.5'
Insulation depth: 8.0'
360 19.0 0.0 0.044 16
Project Title: Lot 12 Lindemann
Data filename: C:\Users\mau\Documents\AutoCAD LT 2015 drawings\REScheck\CURRENT 2012
CODE\Jesse Allen Lot 12 Lindemann 230 Kenneth Dt 2019.09.06.rck
Page 1 of 2
09/06/19Report date:
09/10/19
BLD19-00496
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-ValueU-Factor UA
Basement Wall 2: Solid Concrete or Masonry
Orientation: Left side
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
216 19.0 0.0 0.045 10
Basement Wall 3: Solid Concrete or Masonry
Orientation: Right side
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
216 19.0 0.0 0.045 10
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Notes:
Project Title: Lot 12 Lindemann
Data filename: C:\Users\mau\Documents\AutoCAD LT 2015 drawings\REScheck\CURRENT 2012
CODE\Jesse Allen Lot 12 Lindemann 230 Kenneth Dt 2019.09.06.rck
Page 2 of 2
09/06/19Report date:
09/10/19
BLD19-00496
2012 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
19.00Above-Grade Wall
19.00Below-Grade Wall
0.00Floor
50.00Ceiling / Roof
_______Ductwork (unconditioned spaces):
Glass & Door Rating SHGCU-Factor
0.30Window
0.15Door
Heating & Cooling Equipment Efficiency
_______Heating System:_________________________
_______Cooling System:_________________________
_______Water Heater:___________________________
Name: Date:
Comments
09/10/19
BLD19-00496