HomeMy WebLinkAbout236 Kenneth Dr energy auditREScheck Software Version 4.6.4 Compliance Certificate Project Lot 11 Lindemann Energy Code:2012 IECC Location:Iowa City, Iowa Construction Type:Single-family Project Type:New Construction Orientation:Bldg. faces 270 deg. from North Conditioned Floor Area: 2,544 ft2 Glazing Area 13% Climate Zone: 5 (6227 HDD) Permit Date: Sep 2019 Construction Site: 236 Kenneth Dr. Iow City, IA Owner/Agent: Jesse Allen Allen Homes 530-8238 Designer/Contractor: Michael Untrauer Untrauer Drafting Service, Inc. 2260 Shropshire Circle Coralville, IA 52241 319 430-0760 untrauer@gmail.com Permit Number: Compliance: Passes using UA trade-off 0.0% Better Than Code Maximum UA: 231 Your UA: 231 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-ValueU-Factor UA Ceiling: Flat Ceiling or Scissor Truss 1,272 49.0 0.0 0.026 33 Exterior Wall 1: Wood Frame, 16" o.c. Orientation: Front 414 20.0 0.0 0.059 19 Window 1: Vinyl Frame:Double Pane with Low-E Orientation: Front 50 0.300 15 Door 1: Solid Orientation: Front 38 0.150 6 Wall 2: Wood Frame, 16" o.c. Orientation: Back 414 20.0 0.0 0.059 17 Window 2: Vinyl Frame:Double Pane with Low-E Orientation: Back 122 0.300 37 Wall 3: Wood Frame, 16" o.c. Orientation: Left side 297 20.0 0.0 0.059 18 Wall 4: Wood Frame, 16" o.c. Orientation: Right side 297 20.0 0.0 0.059 17 Window 4: Vinyl Frame:Double Pane with Low-E Orientation: Right side 9 0.300 3 Basement Wall 1: Solid Concrete or Masonry Orientation: Front Wall height: 8.0' Depth below grade: 7.5' Insulation depth: 8.0' 384 15.0 0.0 0.053 20 Project Title: Lot 11 Lindemann Data filename: C:\Users\mau\Documents\AutoCAD LT 2015 drawings\REScheck\CURRENT 2012 CODE\Jesse Allen lot 11 Lindemann 236 Kenneth Dr. 2019.09.16.rck Page 1 of 2 09/16/19Report date: 09/24/19 BLD19-00537 Assembly Gross Area or Perimeter Cavity R-Value Cont. R-ValueU-Factor UA Basement Wall 2: Solid Concrete or Masonry Orientation: Left side Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' 220 15.0 0.0 0.056 12 Basement Wall 3: Solid Concrete or Masonry Orientation: Right side Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' 220 15.0 0.0 0.056 12 Basement Wall 4: Solid Concrete or Masonry Orientation: Unspecified Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' 368 15.0 0.0 0.061 22 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Notes: Project Title: Lot 11 Lindemann Data filename: C:\Users\mau\Documents\AutoCAD LT 2015 drawings\REScheck\CURRENT 2012 CODE\Jesse Allen lot 11 Lindemann 236 Kenneth Dr. 2019.09.16.rck Page 2 of 2 09/16/19Report date: 09/24/19 BLD19-00537 2012 IECC Energy Efficiency Certificate Insulation Rating R-Value 20.00Above-Grade Wall 15.00Below-Grade Wall 0.00Floor 49.00Ceiling / Roof _______Ductwork (unconditioned spaces): Glass & Door Rating SHGCU-Factor 0.30Window 0.15Door Heating & Cooling Equipment Efficiency _______Heating System:_________________________ _______Cooling System:_________________________ _______Water Heater:___________________________ Name: Date: Comments 09/24/19 BLD19-00537