HomeMy WebLinkAbout236 Kenneth Dr energy auditREScheck Software Version 4.6.4
Compliance Certificate
Project Lot 11 Lindemann
Energy Code:2012 IECC
Location:Iowa City, Iowa
Construction Type:Single-family
Project Type:New Construction
Orientation:Bldg. faces 270 deg. from North
Conditioned Floor Area: 2,544 ft2
Glazing Area 13%
Climate Zone: 5 (6227 HDD)
Permit Date: Sep 2019
Construction Site:
236 Kenneth Dr.
Iow City, IA
Owner/Agent:
Jesse Allen
Allen Homes
530-8238
Designer/Contractor:
Michael Untrauer
Untrauer Drafting Service, Inc.
2260 Shropshire Circle
Coralville, IA 52241
319 430-0760
untrauer@gmail.com
Permit Number:
Compliance: Passes using UA trade-off
0.0% Better Than Code Maximum UA: 231 Your UA: 231
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-ValueU-Factor UA
Ceiling: Flat Ceiling or Scissor Truss 1,272 49.0 0.0 0.026 33
Exterior Wall 1: Wood Frame, 16" o.c.
Orientation: Front
414 20.0 0.0 0.059 19
Window 1: Vinyl Frame:Double Pane with Low-E
Orientation: Front
50 0.300 15
Door 1: Solid
Orientation: Front
38 0.150 6
Wall 2: Wood Frame, 16" o.c.
Orientation: Back
414 20.0 0.0 0.059 17
Window 2: Vinyl Frame:Double Pane with Low-E
Orientation: Back
122 0.300 37
Wall 3: Wood Frame, 16" o.c.
Orientation: Left side
297 20.0 0.0 0.059 18
Wall 4: Wood Frame, 16" o.c.
Orientation: Right side
297 20.0 0.0 0.059 17
Window 4: Vinyl Frame:Double Pane with Low-E
Orientation: Right side
9 0.300 3
Basement Wall 1: Solid Concrete or Masonry
Orientation: Front
Wall height: 8.0'
Depth below grade: 7.5'
Insulation depth: 8.0'
384 15.0 0.0 0.053 20
Project Title: Lot 11 Lindemann
Data filename: C:\Users\mau\Documents\AutoCAD LT 2015 drawings\REScheck\CURRENT 2012
CODE\Jesse Allen lot 11 Lindemann 236 Kenneth Dr. 2019.09.16.rck
Page 1 of 2
09/16/19Report date:
09/24/19
BLD19-00537
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-ValueU-Factor UA
Basement Wall 2: Solid Concrete or Masonry
Orientation: Left side
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
220 15.0 0.0 0.056 12
Basement Wall 3: Solid Concrete or Masonry
Orientation: Right side
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
220 15.0 0.0 0.056 12
Basement Wall 4: Solid Concrete or Masonry
Orientation: Unspecified
Wall height: 8.0'
Depth below grade: 6.0'
Insulation depth: 8.0'
368 15.0 0.0 0.061 22
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Notes:
Project Title: Lot 11 Lindemann
Data filename: C:\Users\mau\Documents\AutoCAD LT 2015 drawings\REScheck\CURRENT 2012
CODE\Jesse Allen lot 11 Lindemann 236 Kenneth Dr. 2019.09.16.rck
Page 2 of 2
09/16/19Report date:
09/24/19
BLD19-00537
2012 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
20.00Above-Grade Wall
15.00Below-Grade Wall
0.00Floor
49.00Ceiling / Roof
_______Ductwork (unconditioned spaces):
Glass & Door Rating SHGCU-Factor
0.30Window
0.15Door
Heating & Cooling Equipment Efficiency
_______Heating System:_________________________
_______Cooling System:_________________________
_______Water Heater:___________________________
Name: Date:
Comments
09/24/19
BLD19-00537