HomeMy WebLinkAbout3/20/2002 building permitPermit #:
Issued:
Applicant Name '
Job Address:
Parcel #:
Zone:
Project Name '
BUILDING PERMIT
City of Iowa City
BLD01-00655
10/1 8/2OO 1
RONALD G & NICOLE L S NEEMS
1801 MORNINGSIDEDR
1 011453004
?
ADDITION
CITY OF I0 WA CITY
................................... Applicant .............................................................. Contractor ..................................
RONALD G & NICOLE L S NEEMS DON ROBINSON
1801 MORNINGSIDE DR 505 EAST WASHINGTON STREET
IOWA CITY, IA 5224 5 IOWA CITY, IA 52240
LEGAL DESCRIPTION: SUBDIVISION: MORNINGSIDE ADD
PROJECT DESCRIPTION: 22'X 24' TWO STORY ADDITION
BLOCK :06 LOT: 0017
TYPE OF USE: RSF BEDROOMS: 1 LOT.
DWELL UNITS: 0 DIM.:
TYPE OF IMPR: ADD STRUCTURE AREA: sf
FRAME TYPE: WOOD DIM: 22'X 24' SETBACKS (ft)-
OCCGROUP: R-3 AREA: 528.00sf FR: 19.80
TYPE CONST: 5-N GARAGE LT: 32.00
BASEMENT?: ? DIM: 22'X 24' CONT PRICE:
STORIES: 2.00 AREA: 528.00 sf
RE: 25.00
RT: 20.00
$120,000
ZONING DISTRICT: RS-5
OVERLAY ZON E:
REQ'D PARKING: 2.00
FIRE DETECT REQ'D?: Y
FIRE SPKLRS REQ'D?: N
FIRE EXTING REQ'D?: N
AIRPORT ZONE: N
FLOODPLAIN: N
TREE ORD APPLIC?: N
HANDICAP REQ APPLIC?: N
ST ENER CODE APPLIC?: Y
CERT OF OCC REQ'D?: Y
NOTICE: Separate permits are required for building, electrical, plumbing, heating, air conditioning, or signs. This permit becomes null and void if
work or construction authorized is not commenced within 180 days, or if construction orwork is suspended or abandoned for a period of 180
days at any time after work is commenced.
All provisions of laws and ordinances governing this work must be complied with whether specified herein or not. This permit does not presume
to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction.
Signature of Applicant Date ¢ '
Signature of Building Official
1 - Original 2 - Inspector 3 - Office 4 - Customer
bid prmt.rpt
PLAN CHECK SIGN-OFF SHEET
Case #: BLD01-00655
Date: 10/18/2001
Applicant Name: RONALD G & NICOLE L S NEEMS
Site Address: 1801 MORNINGSIDE DR
Project Name: ADDITION
CITY OF I0 WA CITY
PLAN REVIEW COMMENTS
Reviewer: TJG
1) NEED ENERGY AUDITok
2) SMOKE DETECTORS MUST BE INSTALLED IN EVERY BEDROOM AND HALLWAY LEADING
TO AND ON EACH FLOOR LEVEL
3) 20 MIN SELF-CLOSING/LATCHING DOOR REQUIRED BETWEEN HOUSE AND GARAGE
4) NEW BEDROOM REQUIRED TO BE PROVIDED WITH AN EGRESS WINDOW
5) THIS PERMIT DOES NOT INCLUDED SCREEN PORCH. THERE ARE NO PLANS
6) FOUNDATION MUST EXTEND A MINIMUM 6" ABOVE FINISHED GRADE
7) MUST PROVIDE CONFORMING ATTIC ACCESS 20" X 30"
8) MUST PROVIDE A MINIMUM 3' X 3' LANDING AT FRONT DOOR
9) MECHANICAL ROOM NEEDS TIGHT FITTING DOOR WITH SMOKE SEAL
10) PLANS DRAWN BY A ARCHITECT NEEDS TO BE STAMPED BY AN A ARCHITECT
PLAN REVIEW NOTES MAY NOT REFLECT ALL CODE DEFICIENCIES. Failure to identify a
code deficiency during a review of plans does not alleviate any obligation to comply with all
applicable code provisions.
I, the undersigned, acknowledge receipt of these comments and understand that they constitue
conditions on which this permit is being issued.
Sign~'t~e of A~)p'--I'icant/Agent
Date
bld plan.rpt
Receipt Number:
Check Number:
Date:
Name:
Address:
Case Number:
Parcel Number:
Project Add ress:
Account Number
1342.0-43679
1342.0-41419
00000000000000010688
5615
10/18/2001 9:29:21AM
RONALD G & NICOLE L S NEEMS
1801 MORNINGSIDE DR
IOWA CITY, IA 52245
BLD01-00655
10114530O4
1801 MORNINGSIDE DR
Description
PLAN CHECK- RES
PERMIT FEE - RES
CITY OF I0 WA CITY
Amount Paid
$268.00
$268.OO
Total Amount Paid: $536.00
MECcheck COMPLIANCE REPORT
1995 CABO Model Energy Code
MECcheck Software Version 2.07 Release 4
TITLE: Neems Residence
Permit
Checked by/Date
CITY: Iowa City
STATE: Iowa
HDD: 6227
CONSTRUCTION TYPE: Single Family
DATE: 10-16-2001
DATE OF PLANS: September, 2001
PROJECT INFORMATION:
1801 Morningside Dr.
Iowa City, Ia
Garage- Master bedroom/ Bath Addition
COMPANY INFORMATION:
D. W. Robinson Builder, Inc.
511 E. Washington St.
Iowa City, Iowa 52240
COMPLIANCE: PASSES
Required UA = 164
Your Home = 128
21.8% Better Than Code
Area or
Perimeter
CR-avia~uYe R-CSan~t~e Gul-~i~°r UA
CEILINGS: Raised Truss 0 0.0 0.0
CEILINGS 528 36.0 0.0
WALLS: Wood Frame, 16" O.C. 628 19.0 0.0
GLAZING: Windows or Doors 108
FLOORS: Over Unconditioned Space 528 19.0 0.0
HVAC EQUIPMENT: Furnace, 96.0 AFUE
0.450
0
16
38
49
25
COMPLIANCE STATEMENT: The proposed building design described here is
consistent with the building plans, specifications, and other calculations
submitted with the permit application. The proposed building has been
designed to meet the requirements of the 1995 CABO Model Energy Code.
Builder/Designer, ~W~, .~ -~~--~ Date
40Tr .__B_ I1LD[NG PERMIT APPLICATION
Lot & Subdivision:
410 E. Washington Street
Iowa City, IA 52240
(319) 356-5120
fax (319) 356-5009
Address:
City: ~'OCL~(~L
Dagtime Phone: Other Phone:
Zip ,5-'o% r")- ~--
City: ~0~o~ d ,'~ State ~ [~
Daytime Phone: ~ %~ ) ) ~ ) Other Phone:
Project Description: A ~A t' { "0 g~
· Total Value of Project:
· Permit Value of Project:
./~10 ~ o O. O~r
IExclude cost o~ landl
(Exclude cost of plumb., mech., dec. & land)
Contact Person:
Foundation Exception Used:
I 2 3
Phone:
Is project subject to:
Iowa Architectural law? ................
Formal site plan review?
Plot plan review?
Energy Code review?
Historic preservation review?
Flood plain regulations? ................
Yes No
[] []
[] []
[] []
[] []
[] []
[] []
TO BE COMPLETED BY STAFF:
SiteZ°ne:J~ ~~-'~ ~
Lot Area:
Fees/Escrows Required:
Staff Initials: