Loading...
HomeMy WebLinkAbout3/20/2002 building permitPermit #: Issued: Applicant Name ' Job Address: Parcel #: Zone: Project Name ' BUILDING PERMIT City of Iowa City BLD01-00655 10/1 8/2OO 1 RONALD G & NICOLE L S NEEMS 1801 MORNINGSIDEDR 1 011453004 ? ADDITION CITY OF I0 WA CITY ................................... Applicant .............................................................. Contractor .................................. RONALD G & NICOLE L S NEEMS DON ROBINSON 1801 MORNINGSIDE DR 505 EAST WASHINGTON STREET IOWA CITY, IA 5224 5 IOWA CITY, IA 52240 LEGAL DESCRIPTION: SUBDIVISION: MORNINGSIDE ADD PROJECT DESCRIPTION: 22'X 24' TWO STORY ADDITION BLOCK :06 LOT: 0017 TYPE OF USE: RSF BEDROOMS: 1 LOT. DWELL UNITS: 0 DIM.: TYPE OF IMPR: ADD STRUCTURE AREA: sf FRAME TYPE: WOOD DIM: 22'X 24' SETBACKS (ft)- OCCGROUP: R-3 AREA: 528.00sf FR: 19.80 TYPE CONST: 5-N GARAGE LT: 32.00 BASEMENT?: ? DIM: 22'X 24' CONT PRICE: STORIES: 2.00 AREA: 528.00 sf RE: 25.00 RT: 20.00 $120,000 ZONING DISTRICT: RS-5 OVERLAY ZON E: REQ'D PARKING: 2.00 FIRE DETECT REQ'D?: Y FIRE SPKLRS REQ'D?: N FIRE EXTING REQ'D?: N AIRPORT ZONE: N FLOODPLAIN: N TREE ORD APPLIC?: N HANDICAP REQ APPLIC?: N ST ENER CODE APPLIC?: Y CERT OF OCC REQ'D?: Y NOTICE: Separate permits are required for building, electrical, plumbing, heating, air conditioning, or signs. This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction orwork is suspended or abandoned for a period of 180 days at any time after work is commenced. All provisions of laws and ordinances governing this work must be complied with whether specified herein or not. This permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. Signature of Applicant Date ¢ ' Signature of Building Official 1 - Original 2 - Inspector 3 - Office 4 - Customer bid prmt.rpt PLAN CHECK SIGN-OFF SHEET Case #: BLD01-00655 Date: 10/18/2001 Applicant Name: RONALD G & NICOLE L S NEEMS Site Address: 1801 MORNINGSIDE DR Project Name: ADDITION CITY OF I0 WA CITY PLAN REVIEW COMMENTS Reviewer: TJG 1) NEED ENERGY AUDITok 2) SMOKE DETECTORS MUST BE INSTALLED IN EVERY BEDROOM AND HALLWAY LEADING TO AND ON EACH FLOOR LEVEL 3) 20 MIN SELF-CLOSING/LATCHING DOOR REQUIRED BETWEEN HOUSE AND GARAGE 4) NEW BEDROOM REQUIRED TO BE PROVIDED WITH AN EGRESS WINDOW 5) THIS PERMIT DOES NOT INCLUDED SCREEN PORCH. THERE ARE NO PLANS 6) FOUNDATION MUST EXTEND A MINIMUM 6" ABOVE FINISHED GRADE 7) MUST PROVIDE CONFORMING ATTIC ACCESS 20" X 30" 8) MUST PROVIDE A MINIMUM 3' X 3' LANDING AT FRONT DOOR 9) MECHANICAL ROOM NEEDS TIGHT FITTING DOOR WITH SMOKE SEAL 10) PLANS DRAWN BY A ARCHITECT NEEDS TO BE STAMPED BY AN A ARCHITECT PLAN REVIEW NOTES MAY NOT REFLECT ALL CODE DEFICIENCIES. Failure to identify a code deficiency during a review of plans does not alleviate any obligation to comply with all applicable code provisions. I, the undersigned, acknowledge receipt of these comments and understand that they constitue conditions on which this permit is being issued. Sign~'t~e of A~)p'--I'icant/Agent Date bld plan.rpt Receipt Number: Check Number: Date: Name: Address: Case Number: Parcel Number: Project Add ress: Account Number 1342.0-43679 1342.0-41419 00000000000000010688 5615 10/18/2001 9:29:21AM RONALD G & NICOLE L S NEEMS 1801 MORNINGSIDE DR IOWA CITY, IA 52245 BLD01-00655 10114530O4 1801 MORNINGSIDE DR Description PLAN CHECK- RES PERMIT FEE - RES CITY OF I0 WA CITY Amount Paid $268.00 $268.OO Total Amount Paid: $536.00 MECcheck COMPLIANCE REPORT 1995 CABO Model Energy Code MECcheck Software Version 2.07 Release 4 TITLE: Neems Residence Permit Checked by/Date CITY: Iowa City STATE: Iowa HDD: 6227 CONSTRUCTION TYPE: Single Family DATE: 10-16-2001 DATE OF PLANS: September, 2001 PROJECT INFORMATION: 1801 Morningside Dr. Iowa City, Ia Garage- Master bedroom/ Bath Addition COMPANY INFORMATION: D. W. Robinson Builder, Inc. 511 E. Washington St. Iowa City, Iowa 52240 COMPLIANCE: PASSES Required UA = 164 Your Home = 128 21.8% Better Than Code Area or Perimeter CR-avia~uYe R-CSan~t~e Gul-~i~°r UA CEILINGS: Raised Truss 0 0.0 0.0 CEILINGS 528 36.0 0.0 WALLS: Wood Frame, 16" O.C. 628 19.0 0.0 GLAZING: Windows or Doors 108 FLOORS: Over Unconditioned Space 528 19.0 0.0 HVAC EQUIPMENT: Furnace, 96.0 AFUE 0.450 0 16 38 49 25 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the requirements of the 1995 CABO Model Energy Code. Builder/Designer, ~W~, .~ -~~--~ Date 40Tr .__B_ I1LD[NG PERMIT APPLICATION Lot & Subdivision: 410 E. Washington Street Iowa City, IA 52240 (319) 356-5120 fax (319) 356-5009 Address: City: ~'OCL~(~L Dagtime Phone: Other Phone: Zip ,5-'o% r")- ~-- City: ~0~o~ d ,'~ State ~ [~ Daytime Phone: ~ %~ ) ) ~ ) Other Phone: Project Description: A ~A t' { "0 g~ · Total Value of Project: · Permit Value of Project: ./~10 ~ o O. O~r IExclude cost o~ landl (Exclude cost of plumb., mech., dec. & land) Contact Person: Foundation Exception Used: I 2 3 Phone: Is project subject to: Iowa Architectural law? ................ Formal site plan review? Plot plan review? Energy Code review? Historic preservation review? Flood plain regulations? ................ Yes No [] [] [] [] [] [] [] [] [] [] [] [] TO BE COMPLETED BY STAFF: SiteZ°ne:J~ ~~-'~ ~ Lot Area: Fees/Escrows Required: Staff Initials: