Loading...
HomeMy WebLinkAbout4/2/2002 4417countryclubPermit # · Issued · Applicant Name: Job Address: Parcel #: Zone: Project Name: BUILDING PERMIT City of Iowa City BLD01-00616 10/9/2001 S & J DEVELOPMENT LLP 4417 COUNTRY CLUB DR 1 113453001 COUNTRY CLUB 18 CITY OF I0 WA CITY ................................... Applicant .............................................................. Contractor .................................. S & J DEVELOPMENTS LLP DESIGN BUILDERS, INC. 2231 E 45TH ST 1157 FLAGSTAFF DAVENPORT, IA 52807 IOWA CITY, IA 52246 LEGAL DESCRIPTION · SUBDIVISION ' COUNTRY CLUB ESTATES FIRST ADDITION PROJECT DESCRIPTION ' S.F.D. WITH TWO CAR GARAGE TYPE OF USE: RSF BEDROOMS: DWELL UNITS: 1 TYPE OF IMPR: NEW STRUCTURE. FRAME TYPE: WOOD DIM: 40'X 60' OCC GROUP: R-3 AREA: 1,789.00 sf TYPE CONST: 5-N GARAGE. BASEMENT?: U DIM: 20' X 26' STORIES: 1.00 AREA: 520.00 sf 3 LOT LOT · 18 DIM.: 88'X 125' AREA: 10,989.00 sf SETBACKS (ft) FR: 21.00 RE: 56.00 LT: 21.50 RT: 9.50 CONT PRICE: $130,000 ZONING DISTRICT: RS-5 OVERLAY ZONE: REQ'D PARKING: 2.00 FIRE DETECT REQ'D?: Y FIRE SPKLRS REQ'D?: N FIRE EXTING REQ'D?: N Al RPO RT ZONE: N FLOODPLAIN: N TREE ORD APPLIC?: N HANDICAP REQ APPLIC?: N ST ENER CODE APPLIC?: Y CERT OF OCC REQ'D?: Y NOTICE: Separate permits are required for building, electrical, plumbing, heating, air conditioning, or signs. This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction orwork is suspended or abandoned fora period of 1 80 days at any time after work is commenced. All provisions of laws and ordinances governing this work must be complied with whether specified herein or not. This permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction orthe performance of construction. x ¢(gr~ure 'o.~nl Signatur[e of BCding Official Date 1 - Original 2 - Inspector 3 - Office 4 - Customer bld prmt.rpt PLAN CHECK SIGN-OFF SHEET Case Ct: BLD01-00616 Date: 10/9/2001 Applicant Name: S & J DEVELOPMENT LLP Site Address: 4417 COUNTRY CLUB DR Project Name: COUNTRY CLUB 18 CITY OF I0 WA CITY PLAN REVIEW COMMENTS Reviewer: TJG 1) SMOKE DETECTORS REQUIRED IN EVERY BEDROOM AND HALLWAY LEADING TO AND ON EACH FLOOR LEVEL 2) WINDOWS ENCLOSING BATH TUB REQUIRED TO BE SAFETY GLAZING 3) WINDOWS WITHIN 5' OF BOTTOM STEP OF STAIRS REQUIRED TO BE SAFETY GLAZING 4) DOOR BETWEEN HOUSE AND GARAGE REQUIRED TO BE SELF-CLOSING/LATCHING 5) FOUNDATION INSPECTION REQUIRED MAY NEED ADDITIONAL STEEL IN FOUNDATION 6) ATTC ACCESS REQUIRED 20"X 30" 7) FOUNDATION MUST EXTEND A MINIMUM 6" ABOVE FINISHED GRADE 8) EACH BEDROOM AND BASEMENT REQUIRED TO BE PROVIDED WITH AN EGRESS WINDOW PLAN REVIEW NOTES MAY NOT REFLECT ALL CODE DEFICIENCIES. Failure to identify a code deficiency during a review of plans does not alleviate any obligation to comply with all applicable code provisions. I, the undersigned, ackn_..owtedge receipt of these comments and understand that they constitue condition, s on which t~,l;)er, mit is being issued. S~gnature o~A ca ant Date bid plan.rpt CITY OF I0 WA CITY Site Address: OR Lot & Subdivision: HOUSING & INSPECTION IOWA CiTY ': 410 E. Washington Street Iowa City, IA 52240 (319) 356-5120 fax (319) 356-5009 Owner/Tenant: Address: City: State Zip Daytime Phone: · Total Value of Project: · Permit Value of Project: Other Phone: ( City: ,'--~~c. ~-L State ~ ¢~ Zip Daytime Phone: ~L::~\~, ~,~O- ~ ~ ~ Other Phone: ~ ~~~ .- ~ ~ ~ ~ Q~'~~ Project Description: ~ ~~C~~ ~ ~~ ~, ~ -- (Exclude cost of land) (Exclude cost of plumb., mech., elec. & land) Contact Person: Foundation Exception Used: I 2 3 Is project subject to: Iowa Architectural law? Formal site plan review? ............... Plot plan review? Energy Code review? Historic preservation review? Flood plain regulations? ................ Yes No [] [] [] [] [] [] [] [] TO BE COMPLETED BY STAFF: Site Zone: '~--~ ~ ~ Lot Area: i 0,, ~q ~ -~ Fees/Escrows Required: Other: Staff Initials: MECcheck Compliance Report MECcheck Software Version 3.0 Release la 1995 MEC Edition Permit Number Checked By/Date CITY: Iowa City STATE: Iowa HDD: 6227 CONSTRUCTION TYPE: Single Family DATE: 09/28/01 PROJECT INFORMATION: 1789 SQ. Fl'. 3-4 BEDROOM RANCH WITH 2 STALL GARAGE COMPANY INFORMATION: DESIGN BUILDERS INC. FRANK OVERBECK NOTES: FILE#OVERBECKCCE- 18 LOWER LEVEL REAR WALL TO BE 2x6 IN LIEU OF 2x4 COMPLIANCE: Passes Maximum UA = 329 Your Home = 327 0.6% Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: All-Wood Raised Joist/Rafter/Truss Exterior Wall 1: Wood Frame, 16" o.c. Window 1: Wood Frame, Double Pane with Low-E Door 1: Glass Door 2: Opaque Exterior Wall 2: Solid Concrete or Masonry: Interior Insulation Exterior Wall 3: Wood Frame, 16" o.c. Basement Wall 2: Solid Concrete or Masonry Slab 1: Unheated Fumace 1: Forced Hot Air, 80 AFUE Air Conditioner 1: Electric Central Air, 10 SEER 1789 40.0 3.0 41 1367 13.0 3.0 65 324 0.350 113 82 0.300 25 40 0.300 12 88 11.0 3.0 6 327 19.0 3.0 18 256 11.0 3.0 13 52 14.0 34 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 MEC requirements in MECcheck Version 3.0 Release la. MECchecl Inspection Checklist MECcheck Software Version 3.0 Release la 1995 MEC Edition DATE: 09/28/01 Bldg. Dept. Use [] [] [] [] [] [] [] [] [] [] [] Roofs: 1. Ceiling 1: All-Wood Raised Joist/Rafter/Tress, R-40.0 cavity + R-3.0 continuous insulation Comments/Location Insulation must achieve full height over the plate lines of exterior walls. Above-Grade Walls: 1. Exterior Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.0 continuous insulation Comments/Location 2. Exterior Wall 2: Solid Concrete or Masonry: Interior Insulation, R-11.0 cavity + R-3.0 continuous insulation Comments/Location 3. Exterior Wall 3: Wood Frame, 16" o.c., R-19.0 cavity + R-3.0 continuous insulation Comments/Location Basement Walls: 1. Basement Wall 2: Solid Concrete or Masonry, 8.0' hr/7.5' bg/8.0' iusul, R-11.0 cavity + R-3.0 continuous insulation Comments/Location Windows: 1. Window 1: Wood Frame, Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break9. [ ] Yes [ ] No Comments/Location Doors: 1. Door 1: Glass, U-factor: 0.300 Comments/Location 2. Door 2: Opaque, U-factor: 0.300 Comments/Location Slab-On-Grade Floors: 1. Slab 1: Unheated, 4.0' insulation depth, R- 14.0 continuous insulation Comments/Location Slab insulation to extend down from the top of the slab to at least 4.0 ft. OR down to at least the bottom of the slab then horizontally for a total distance of 4.0 Healing and Cooling Equipment: 1. Fumace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number 2. Air Conditioner 1: ElectficCentralAir, 10 SEER or higher Make and Model Number [] [] [1 [1 [3 [1 [] [] [] [1 [1 [1 [1 Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. Vapor Retarder: Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for ail installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-values, and heating equipment efficiency must be clearly marked on the building plans or spedfications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-6.5. Duct Construction: All ducts must be sealed with mastic and fibrous backing tape. Pressure-sensitive tape may be used for fibrous ducts. Duct tape is not permitted. The HVAC system must provide a means for bancing air and water systems. Temperature Controls: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 120 °F or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Rtmouts Temperature (F) Up to 1" U.p to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range (F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Healing Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refi'igerant, 40-55 0.5 0,5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)