Loading...
HomeMy WebLinkAbout04/18/02 bp653barringtonPermit # · Issued ' Applicant Name: Job Address: Parcel #: Zone: Project Name: BUILDING PERMIT City of Iowa City BLD01-00697 11/9/2001 ARLINGTON DEVELOPMENT INC 653 BARRINGTON RD 0918106013 WINDSOR R 144 CITY OF I0 WA CITY ................................... Applicant .............................................................. Contractor .................................. ARLINGTON DEVELOPMENT INC ARLINGTON DEVELOPMENT, INC. 2346 MORMON TREK BLVD 1476 1ST AVE. % GARY WATTS IOWA CITY, IA 52240 IOWA CITY, IA 52246 LEGAL DESCRIPTION' SUBDIVISION ' WINDSOR RIDGE- PART NINE PROJECT DESCRIPTION ' S.F.D. WITH THREE CAR GARAGE LOT' 144 TYPE OF USE: RSF BEDROOMS: 4 LOT-- DWELL UNITS: 1 DIM.: 76'X 139' TYPE OF IMPR: NEW STRUCTURE ....................... AREA: 9,635.00 sf FRAME TYPE: WOOD DIM: 43'X 59' SETBACKS (ft) OCC GROUP: R-3 AREA: 1,885.00 sf FR: 25.00 RE: TYPE CONST: 5-N GARAGE .......................... LT: 5.00 RT: BASEMENT?: F DIM: 24'X 33' CONT PRICE: STORIES: 1.00 AREA: 792.00 sf 58.00 6.00 $151,274 ZONING DISTRICT: RS-5 OVERLAY ZONE: REQ'D PARKING: 2.00 FIRE DETECT REQ'D?: Y FIRE SPKLRS REQ'D?: N FIRE EXTING REQ'D?: N AIRPORT ZONE: N FLOODPLAIN: ? TREE ORD APPLIC?: N HANDICAP REQ APPLIC?: N ST ENER CODE APPLIC?: Y CERT OF OCC REQ'D?: Y NOTICE: Separate permits are required for building, electrical, plumbing, heating, air conditioning, or signs. This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction orwork is suspended or abandoned fora period of 1 80 days at any time after work is commenced. All provisions of laws and ordinances governing this work must be complied with whether specified herein or not. This permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. Sign a(~re of Applicant Date Signature of Building Official 1 - Original 2 - Inspector 3 - Office 4 - Customer bid prmt.rpt PLAN CHECK SIGN-OFF SHEET Case #' BLD01-00697 Date · 11/9/2001 Applicant Name · ARLINGTON DEVELOPMENT INC Site Address · 653 BARRINGTON RD Project Name · WINDSOR R 144 CITY OF I0 WA CITY PLAN REVIEW COMMENTS Reviewer · TJG 1) SMOKE DETECTORS MUST BE INSTALLED IN EVERY BEDROOM AND HALLWAY LEADING TO AND ON EACH FLOOR LEVEL 2) FOUNDATION INSPECTION REQUIRED SPECIAL STEEL AND INSPECTION REQUIRED 3) SAFETY GLAZING REQUIRED IN WINDOW IN TUB WALL 4) MAKE UP AIR REQUIRED IN LAUNDRY ROOM 5) SELF-CLOSING/LATCHING DOOR REQUIRED BETWEEN HOUSE AND GARAGE 6) STORAGE UNDER STAIRS MUST BE PROTECTED ON THE STORAGE SIDE BY 1 HOUR 7) GARDEN ROM MUST BE SEPERATED FROM REST OG THE HOME BY 1 HOUR CONSTRUCTION. DOOR FROM GARDEN ROOM TO PLAY ROOM MUST BE 1 HOUR S ELF-CLOS I N G/LATCHING PLAN REVIEW NOTES MAY NOT REFLECT ALL CODE DEFICIENCIES. Failure to identify a code deficiency during a review of plans does not alleviate any obligation to comply with all applicable code provisions. I, the undersigned, acknowledge receipt of these comments and understand that they constitue conditions on which this permit is being issued. Signature of Applicant/Agent Date bid plan.mt Receipt Number: Check Number: Date: Name: Address: Case Number: Parcel Number: Project Address: Account Number 1342.0-43679 1342.0-41419 00000000000000010967 1825 11/9/2001 11:17:56AM ARLINGTON DEVELOPMENT INC 2346 MORMON TREK BLVD % GARY WATTS IOWA CITY, IA 52246 BLD01-00697 0918106013 653 BARRINGTON RD Description PLAN CHECK- RES PERMIT FEE - RES CITY OF I0 WA CITY Total Amount Paid: Amount Paid $331.00 $331.00 $662.00 HOV--07--01 02:26 PM VRH WIHKLE--J~CO~¢RLYL 1~1~~? Van Winkle-.lacob Bngineerjng~ Inc. 2570 tloli#ay Roa Cora~fllo, Iowa 5224~ November 7, 2001 City Building Inspector lowa City Building Department Iowa City, Iowa $2240 To Whom It May Concern: / I have reviewed the Plans for the proposed building for Arlington Development (Lot 144 Windsor Ridge-653 Ban-ington Rd.). Thi~. review is for thc building enclosure requirements only. The plan is within compliance of'thc i 992 Model Encrg~ Code. The plans, a~ r~¥/ewed, will need the following additions to comply with fl~c building !nclo;ure requirements of the 1992 Model Energy Cod=. , Lnsulat¢ ~antilcvcrcd floor to R-38. Basement wall.~ shall be fhrred ut with 2 x ~'s and 1. The windows/doors shall have a minimum R-value of 2.41. 2, Exterior box sill insulation shall ¢on-~ist of a minim,~m R-! 9 fiberglass. 3. 4, nsulated to a minimum R-11. I hereby certify that this document was prepared by me or un and tiaa[ I am a duly Licensed Engineer raider the laws of the 8 01-160 der my direct personal supervision tare of Iowa. tte CITY OF I0 WA CITY Site Address: OR Lot & Subdivision: BUILDING P~ERIVi~ APPLI' 410 E. Washington Street CJ L] NOV"I 2001 HOUSING & INSPECTION SERVICES: City: Daytime Phone: Contractor: ~~ IOWA CITY, IOWA 240 009 State Other Phone: Zip Address: City: Daytime Phone: Project Description: State Other Phone: Zip Contact Person: Total Value of Project: $ (Exclude cost of land) Permit Value of Project: $ ~,~.~ (Exclude cost of plumb., mech.., elec. &/l~nd) Foundation Exception Used: 1 2 3 Phone: Is project subject to: Yes Iowa Architectural law? ................ [] Formal site plan review? ............... [] Plot plan review? [] Energy Code review? [] Historic preservation review? [] Flood plain regulations? ................ [] No [] [] [] [] [] [] TO BE COMPLETED BY STAFF: Site Zone: Lot Area: Fees/Escrows Required: Other: Staff Initials: