Loading...
HomeMy WebLinkAbout4/18/02 bp4605drydenPermit # · Issued ' Applicant Name: Job Address: Parcel #: Zone: Project Name: BUILDING PERMIT City of Iowa City BLD01-00687 11/6/2001 JEANNE MELICK-SHIELD 4605 DRYDEN CT 0918108017 WINDSOR R 216 CITY OF I0 WA CITY ................................... Applicant .............................................................. Contractor .................................. H FILMORE & MARJORY M MELICK SGA 512 N CLAY ST PO BOX 252 WEST LIBERTY, IA 52776 WEST LIBERY, IA 52776 LEGAL DESCRIPTION · SUBDIVISION · WINDSOR RIDGE - PART TEN PROJECT DESCRIPTION · S.F.D. WITH TWO CAR GARAGE LOT' 0216 TYPE OF USE: RSF BEDROOMS: 2 LOT DWELL UNITS: 1 DIM.: IRREGULAR TYPE OF IMPR: NEW STRUCTURE .................. AREA: 14,491.00 sf FRAME TYPE: WOOD DIM: 40'X 49' SETBACKS (ft) CCC GROUP: R-3 AREA: 1,960.00 sf FR: RE: TYPE CONST: 5-N GARAGE .......................... LT: RT: BASEMENT?: U DIM: 24'X 24' CONT PRICE: STORIES: 1.00 AREA: 576.00 sf $225,000 ZONING DISTRICT: RS-5 OVERLAY ZONE: REQ'D PARKING: 2.00 FIRE DETECT REQ'D?: Y FIRE SPKLRS REQ'D?: N FIRE EXTING REQ'D?: N AIRPORT ZONE: N FLOODPLAIN: N TREE ORD APPLIC?: N HANDICAP REQ APPLIC?: N ST ENER CODE APPLIC?: Y CERT OF CCC REQ'D?: Y NOTICE: Separate permits are required for building, electrical, plumbing, heating, air conditioning, or signs. This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction orwork is suspended or abandoned for a period of 1 80 days at any time after work is commenced. All provisions of laws and ordinances governing this work must be complied with whether specified herein or not. This permit does not presume to give authority to violate or cancel the p~ovisions of any other state or local law regulating construction or the performance of construction. si'g/g~ature (~f A ~p~car~t'-- Date S~'e of ~'uilding Official I - Original 2 - Inspector 3 - Office 4 - Customer bid prmt.rpt PLAN CHECK SIGN-OFF SHEET Case #: BLD01-00687 Date: 11/6/2001 Applicant Name: JEANNE MELICK-SHIELD Site Address : 4605 DRYDEN CT Project Name: WINDSOR R 216 CITY OF I0 WA CITY PLAN REVIEW COMMENTS Reviewer: JLR 1) NEED SITE PLANok 2) SMOKE DETECTORS MUST BE INSTALLED IN EVERY BEDROOM AND HALLWAY LEADING TO AND ON EACH FLOOR LEVEL 3) SELF-CLOSING 20 MIN DOOR REQUIRED BETWEEN GARAGE AND HOUSE 4) 1 HOUR CONSTRUCTION REQUIRED ON GARAGE SIDE OF GARAGE/HOUSE WALL 5) EACH BEDROOM IS REQUIRED TO HAVE AN EGRESS WINDOW AND ALSO BEDROOM 6) WALKOUT BASEMENT REQUIRES SPECIAL STEEL REQUIREMENTS AND SPECIAL INSPECTIONS 7) WHERE ARE STEPS TO BASEMENT 8) HOLD PLANS PLAN REVIEW NOTES MAY NOT REFLECT ALL CODE DEFICIENCIES. Failure to identify a code deficiency during a review of plans does not alleviate any obligation to comply with all applicable code provisions. I, the undersigned, acknowledge receipt of these comments and understand that they constitue conditions on which this permit is being issued. ~'i~n'at~ure ~of App~can~A" '"-~lent Date bid plan.rvt Untrauer's Draftin~ TEL: 1-319-~38-Sg66 MECcheck Compliance Report MECcheck Software Version 3.0 Release 1 a 1993 MEC Edition TITLE: John and Kayla Cress Resid~n~ Oct 30,01 11:09 No.O01 P.O1 Permit Number Checked By/Date CITY: lowa City STATE: Iowa HDD: 6227 CONSTRUCTION TYPE: Muitifamily DATE: 10/29/01 DATE OF PLANS: 10/29/01 PROJECT INFORMATION: Lot 197 Windsor Ridge- Part Ten COMPLIANCE: Passes Maximum UA = 883 Your Home = 622 29.6% Better Than Code Gross Glazing Area or Cavity Cont. or Door Perime~$r R-Valu~ ~-Value U-Factor U_AA Ceiling 1: Ali-Wood Joisl/Rafler/Truss 1723 38.0 0.0 Exterior Wall 1: Wood Frame, 16" o.c. 2896 19.0 0.0 Window 1: Wood Frame, Double Pane with Low. E 304 Door 1: Opaque 58 Exterior Wall 2: Wood Frame, 16" o.c, 380 19.0 0.0 Door :2: Opaque 63 Basement Wall 1: Solid Concrete or Masonry 1030 11.0 0.0 Window 2: Wood Frame, Double Pane with Low-E 69 Floor 1: All-Wood Joist/Truss, Over Unconditioned Space 136 ! 9.0 0.0 Slab 1: Unheated 64 0.0 Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 1: Electric Central Air, 10 SEER 0.320 0.064 0.064 0.320 52 137 97 4 17 4 216 22 6 67 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to me~t the 1993 M,,.EC requiren~ts in MECcheck Version 3.0 Release I a. CITY OF I0 WA CITY BUILDING PERMIT APPLICATION Site Address: OR Lot & Subdivision: Owner/Tenant: Address: City: Daytime Phone: Contractor: 410 E. Washington Street Iowa City, IA 52240 (319) 356-5120 fax (319) 356-5009 HOUSING & INSPECTION SERVICES IOwA CITY, IOWA State Other Phone: Zip 5-F_,~-)6 Address: ~.O, t~-X Z,5-~. City: !~57 Ltbe¥+7' Daytime Phone: ~/~/~.j Z¢~- ¢-/c/¢ ~ Project Description: State ~T-t~ Zip Other Phone: (~ ~j - 7~c~' 0 · Total Value of Project: $ ~ &~'/.)~ ,~ 0 (Exclude cost of land) · Permit Value of Project: $ ! ~. F__JDD. ~ ~ (Exclude cost of plumb., mech., elec. & land) Contact Person: "~-zz..,~,'~ 5'/~;'~/d Foundation Exception Used: 1 2 3 Phone: 0'(~) Z?'?' "' ~/¥.E~ Is project subject to: Iowa Architectural law? ................ Formal site plan review? ............... PIct plan review? Energy Code review? Historic preservation review? Flood plain regulations7 ................ Yes No [] [] [] [] [] [] [] [] [] [] [] [] TO BE COMPLETED BY STAFF: Site Zone: Lot Area: Fees/Escrows Required: Other: Staff Initials: