Loading...
HomeMy WebLinkAbout07-19-2007 Planning and Zoning Commission PLANNING AND ZONING COMMISSION Monday, July 16, 2007 - 5:15 PM Informal Meeting Iowa City City Hall Lobby Conference Room 410 E. Washington Street AGENDA: Thursday, July 19, 2007 -7:30 PM Formal Meeting Iowa City City Hall Emma J. Harvat Hall 410 E. Washington Street A. Call to Order B. Public Discussion of Any Item Not on the Agenda C. Rezoning Item: REl07-00008: Discussion of an application submitted by Three Bulls, LLC for a rezoning from Central Business Support (CB-5) zone to Central Business (CB-10) zone for approximately 2,035 square feet of property located at 301 S. Dubuque Street and rezoning an additional 9,890 square feet of adjacent property from Neighborhood Public/Central Business Support (P1/CB-5) zone to Central Business District (CB-10) zone. (45-day limitation period: July 19, 2007) C. Comprehensive Plan Item: Public Hearing on an amendment to the Northeast District Plan modifying the plan map for the Lindemann Hills Neighborhood to incorporate a large institutional use into the conceptual street pattern north of the public square along Lower West Branch Road. D. Annexation/Rezoning Item: ANN07-00002/REl07-00010: Discussion of an application for annexation of 14 acres of land owned by Henrietta Miller and 1.89 acres of land owned by the City of Iowa City located north of Lower West Branch Road, north of Brentwood Drive and Broadmoor Lane and the rezoning of 14 acres from County Residential (R) to Low Density Single Family Residential (RS-5) and approximately 1.89 acres from County Residential (R) to Neighborhood Public (P-1). E. Development Item: SUB07-00004/SUB07-00005: Discussion of an application from Tyler Rogers for a preliminary and final plat of North Fifty First Subdivision, a 3-lot, 3.00 acre residential subdivision located west of Kansas Avenue, south of IWV Road SW. (45-day limitation period: August 2,2007) F. Vacation Item: VAC07-00004 Discussion of an application submitted by University of Iowa to vacate a portion of Court Street west of Madison Street and Front Street south of Burlington Street. G. Consideration of the June 21, 2007 and July 12, 2007 Meeting Minutes H. Adjournment Informal Formal October 1 October 4 STAFF REPORT To: Planning & Zoning Commission Prepared by: Sarah Walz Item: REZ07-00008 Dubuque & Burlington Date: July 19, 2007 GENERAL INFORMATION: Applicant: Three Bulls, LLC 33 Hickory Heights Lane Iowa City, IA 52245 Contact Person: Swen Larson Phone: 319-631-5800 Requested Action: Rezoning from CB-5 to CB-1 0 Purpose: Development of a mixed-use residential/commercial building Location: 301 S. Dubuque Street and surrounding City-owned property Size: 2,035 sq. feet of private property + 9,890 sq. feet of public property Existing Land Use and Zoning: Commercial (CB-5) and Public/Commercial (P1/CB-5)) Surrounding Land Use and Zoning: North: Commercial (CB-10) South: Public/Commercial - P/CB-5 East: Residential/Commercial (CB-5) West: Undeveloped Commercial (CB-10) Comprehensive Plan: General Commercial - Near Southside Plan File Date: May 2, 2007 45 Day Limitation Period: June 7, 2007 (waived until July 19) BACKGROUND INFORMATION: The applicant, Three Bulls LLC, is requesting approval for rezoning from Central Business Support Zone (CB-5) to Central Business Zone (CB-10) zone for 2,035 square feet of property located at the Southwest corner of Dubuque and Burlington Streets. The property currently contains the Mod Pod building. The rezoning to CB-10 would allow construction of a proposed thirteen-story building that combines 3 floors of commercial along with residential uses above- approximately 38 residential units. Because the proposed project incorporates the surrounding 9,890 square feet (approx.) of City-owned property currently zoned Public/Commercial Business Support (P1/CB-5) zone, a CB-10 rezoning for this public property is also part of this 2 consideration. The total site size would be approximately .27 acres. Development of the public property included in this re-zoning application was considered as part of the Court Street Transportation Center project. Those plans showed development of a 4- 5 story mixed use commercial building as compatible with the CB-5 zone. However, because the City was unsuccessful in its effort to purchase the privately held property at 301 S. Dubuque, those plans were never fulfilled and the staff anticipated that private development would take place on this property at some point in the future. ANAL YSIS: Comprehensive Plan: The Near Southside Plan was adopted in 1992 as a guide for the redevelopment of the area generally bounded by Burlington Street on the north, Gilbert Street on the east, Madison Street on the west and the Iowa Interstate Railway on the south. Focused on fostering redevelopment of the area directly south of the downtown, while maintaining an economically healthy core in the established downtown, the Plan identifies the area between Court Street and Burlington Street as suitable for office and commercial development with upper story residential uses. The Near Southside Plan encourages higher-density residential development in the area south of Court Street. By allowing higher intensity uses (commercial and residential) south of the downtown, growth is directed away from the historic neighborhoods north of the Central Business District - a goal of the Comprehensive Plan. The Near Southside Plan further identifies the need for addressing the issues of parking, open space, pedestrian accessibility, traffic circulation, historic preservation and amenities. Convenient pedestrian accessibility is crucial to the success and vitality of downtown Iowa City. Protecting and enhancing the shopping convenience and pedestrian accessibility of the downtown area is a goal of the plan. If the area south of Burlington Street is to function as an extension of the downtown a strong physical and aesthetic connection between the downtown and the area south of Burlington Street is also critical. To achieve this goal the plan recommends attention to various aspects of development including public improvements in the streetscape. This includes improving pedestrian safety and accessibility along and across Burlington Street and careful attention to building and site design so as to avoid the creation of a fortress-like or blank streetscape. The City began implementing the Near Southside Plan in 1992 by adopting the CB-5 zone and applying it to the area generally between Court and Burlington Street. The relationship between the CB-10 zone north of Burlington Street and the CB-5 zone to its south was intended to create a hierarchy of taller buildings and greater intensity of development in the downtown core with a step down in height and intensity to the south. The CB-10 zone allows a floor area ratio (FAR) of 10 while the CB-5 zone has a floor area ratio of 3 with the potential FAR of up to 5 if the developer provides certain amenities and public benefits as part of the project. The CB-10 zone itself does not have a maximum height limit; however, the Airport Overlay Zone results in a height limit of approximately 12 to 14 stories depending on the ground elevation of the property. The CB-5 zone has a height limit of 75 feet or approximately 6 stories. The CB-10 does not require parking for either commercial or residential development, while the CB-5 zone requires parking spaces for residential development. Concerns about parking are discussed in more detail below. Recent changes to the Near Souths ide Plan and the CB-10 zoning policy: As part of the Hieronymus Square rezoning the City took a close look at the potential impacts of the CB-10 zone on the downtown core of Iowa City. Although the CB-10 zone allows an FAR of 10 - it was recognized that most of the downtown properties were already developed with a floor area ratio of 2 (Le. a 2 story building covering most of a property). There are a few exceptions, including 3 the Iowa State Bank Building and the Sheraton Hotel, which are built to an FAR of approximately 5, and the Jefferson Building and the Vogal House, both with FARs of approximately 6. However, the construction of the Plaza Towers with an approximate FAR of 4.75 prompted public concern about the redevelopment of large areas of downtown at such an intense level. Since the downtown core itself contains a number of historic buildings and buildings that already display the storefront features necessary for a successful and vibrant city center (and encouraged by the Comprehensive Plan), some questioned whether redevelopment of the downtown core to the height and intensity allowed by the current CB-10 zone would be desirable. A change in policy with regard to Near Southside development was initiated with the CB-10 rezoning of the Hieronymus Square Property at the southeast corner of Burlington and Capital Streets. The logic supporting that rezoning and the amendment to the Near Southside Plan to allow the extension of the CB-10 zone holds that much of the current CB-5 area south of Burlington Street-as well as the north side of Burlington Street, which is already zoned CB- 1 O-contains few buildings that have the characteristics envisioned for the downtown. It was decided that encouraging redevelopment of this area by extending the CB-10 zoning to just south of Burlington Street would reduce redevelopment pressure on the downtown core where the desirable pedestrian-oriented streetscape and buildings are already in place and that CB-1 0 zoning would be appropriate provided that adequate parking and pedestrian connections to the established downtown are provided. Another justification for amending the Near Southside Plan, and a condition of the Hieronymus rezoning, was the potential benefit of diversifying the mix of housing stock downtown. The success of Plaza Towers suggested that a market exists for a different sort of high-rise residential development downtown. Development of mixed-use buildings with a variety of residential sizes including larger condominiums, as proposed by Hieronymus, would help to further diversify the housing stock and land uses in downtown and help support the commercial development envisioned by the Comprehensive Plan for the downtown and the Near Southside. The CB-5 zone south of Burlington Street allows mixed use buildings, but the height limit prevents buildings taller than 6 stories and thus buildings with the views desired for the high- rise condominium market could not be built. The conditional zoning agreement for Hieronymus Square requires a mix of studio or 1, 2 and 3-bedroom units, with nor more than 30% of the units containing 3 bedroom, and no units were allowed more than 3 bedrooms. The amendment to the Near Southside Design Plan states that "Either CB-5 or CB-1 0 are appropriate between Court and Burlington Streets, based on the property providing a logical extension of the downtown and adequate services for the density proposed. If the conditions discussed below are addressed it appears that the proposed rezoning for 301 S. DUbuque Street and surrounding public property to CB-10 complies with the Comprehensive Plan as amended. Conditions for CB-10 rezoning south of Burlington Street: 1. Parking: The Comprehensive Plan notes that some downtown merchants and business owners feel the residential population burdens the parking system in the district to the detriment of businesses. The Plan discusses the need to establish a clear policy for housing, parking and redevelopment in the Downtown Planning District, which includes the established downtown and the Near Souths ide area. When the City completed its study of the redevelopment potential in the Near Southside, several measures were taken to address the demand and supply of parking for new commercial and residential development in this area, including the creation of the Near Southside Parking Facility District. Because residential parking demand is fundamentally different than the demand for short term commercial parking, policies and regulations were set in place to make 4 sure that any new residential development would pay its fair share of demand on City parking facilities. Development within the CB-5 zone is required to pay a fee for 75% of the required parking spaces for residential units. The fee is to be used to support the creation of new public parking facilities necessary to accommodate the resulting increased demand for off-street parking created by additional residential development. Currently the fee is $6,119 per parking space and represents less than 1/3 the cost of building a structured parking space. Because the CB-10 zone requires no residential parking, the fee would not normally apply to areas rezoned to CB-10. To insure adequate parking is provided and to treat residential development equitably with CB-5 properties that have paid or will pay the fee, staff recommended any properties south of Burlington Street rezoned to CB-1 0, be required to pay the parking impact fee as if they were in the CB-5 zone. This arrangement was a condition of the Hieronymus Square rezoning. If 301 S. Dubuque were treated the same as Hieronymus Square, all 1 and 2 bedroom residential units would require a minimum of one parking space and any 3-bedroom units would require a minimum of 2 parking spaces. If the building were developed with 38 units with the maximum of 11 units having 3 bedrooms, the building would be required to provide 49 parking spaces.1 A fee of $299,8312 would be paid to cover all 49 spaces since no parking can be provided on this small site. Subject to City Council approval a second parking facility is planned for construction in the Near Southside, so it is likely that any fees collected for residential units at 301 S. Dubuque (as well as Hieronymus Square) will be expended in the next 5 years. Court Street Transportation Center permits are currently sold out. All available permits have been issued to the University. It is the City's policy to make these permits available for development projects in the area as they occur. The University has been put on notice that when permits are needed for development that University permits will not be renewed. 2. Design: The Near Southside Design Plan was adopted in 1995 to provide more clear direction for implementing the Near Southside Plan. The Design Plan's vision for the Downtown Extension area states that redevelopment efforts should architecturally mirror the existing Downtown area. "New structures in this district and along Burlington Street reflect the scale, proportion, fayade repetition, setbacks, materials, roof lines, color, signage, awnings, and equipment screening elements of the adjacent Downtown. . . . This character can be further enhanced through implementation of design guidelines and review process to address each of these design elements within the Downtown Extension ." To implement this goal the zoning code provides Site Development Standards for the CB-5 and CB-10 zones focusing on street-level building facades in order to prevent fortress-like facades, monotonous streetscapes, and to enhance public safety by providing opportunities for views of the street from the interior of buildings. The standards are intended to create commercial spaces that are both attractive and functional by encouraging designs that address the pedestrian at street level--spaces that are both visually and physically accessible. The code also requires a 10-foot setback from the right-of-way line for the first story of buildings that abuts Burlington Street. This is to provide more space for pedestrian movement, and the placement of 1 With a maximum of one-third of the units having more than 2 bedrooms: 11 units would require 2 parking spaces each (22 spaces) + the remaining 27 units requiring 1 space each (27 spaces) = 49 parking spaces. 2 The parking impact fee is adjusted for inflation on an annual basis. 5 amenities within and adjacent to the right-of-way to provide a buffer between vehicular traffic and pedestrians along Burlington Street. The code allows building columns supporting upper stories to be located within this 10-foot setback, provided that an adequate pedestrian passageway is maintained. Due to concerns that a proposed building with upper floors cantilevered to the property line would overwhelm the pedestrian area and create a canyon effect along Burlington Street, the Planning and Zoning Commission recommended through the conditional zoning agreement that the Hieronymus building maintain the 10-foot setback for the entire height of the building, not just the first floor. To maintain consistency along the street, similar conditions should also apply to the development at 301 S. Dubuque Street. The applicant has provided a preliminary sketch of the proposed building, which has been reviewed by planning staff. (A final drawing will need to be reviewed by the Design Review Committee.) Staff believes that the general form of the building as shown in the submitted sketches meets these design requirements. The elevation for the first floor commercial space shows that the ground floor will be at grade for the entire length of the building and includes articulation through the use of linear columns to break up the plane of the building. Storefronts are recessed and include canopies over all entrances to the building. Because of its similar height and design, staff was initially concerned that the proposed building would appear to be an extension of the Hieronymus development. To address this concern the architect added three angled bays on the residential floors and broke up the roofline. To accommodate the bays, staff recommends allowing the extension of the bays 5-6 feet into the setback as allowed in the zoning code. Staff does not believe that the angled bays as proposed in the submitted plan, will create a canyon effect that is a concern along this portion of Burlington Street. 3. Traffic implications: Since Burlington Street is a high-volume arterial street, direct access is restricted. The concept plan submitted by the applicant indicates no on-site parking, rather all parking will be provided in the public ramp, which has access from Dubuque and Court Streets. The City is planning a landscaped median in Burlington Street to provide for safer pedestrian and vehicular traffic in this area. A number of improvements to the public right-of-way are included as part of the Hieronymus Square development, including landscaping along the south side of Burlington in order to provide separation between vehicle traffic and pedestrian space. Because the pedestrian walkway will be provided on private property within the required 10-foot setback, along Burlington Street, a public access easement along the entire 10-foot walkway will be necessary. SUMMARY In 2006, the Comprehensive Plan was amended to allow the extension of the CB-10 zone within the Near Souths ide Development Areas, between Burlington and Court Streets, so long as concerns with regard to parking, design, and traffic were addressed. The expansion of the CB- 10 development was intended to encourage a diversity of housing types in the downtown while at the same time providing for areas of additional commercial growth. In addition, allowing the CB-10 zoning to expand into this area will reduce pressure for high-rise development within the historic downtown core. Provided that property proposed for CB-1 0 zoning addresses issues of parking, design, and traffic issues in a manner that supports the downtown as a pedestrian accessible, economically vibrant commercial area, such a rezoning may be justified. Staff believes that the proposed development for 310 S. Dubuque Street and the surrounding City- owned property meets these goals. 6 RECOMMENDATION Staff recommends that REZ07-00008, a request to rezone approximately .27 acres of property from CB-5 and P1/CB-5 to CB-10 be approved granted subject to the following conditions: a. The building to be constructed on this property will be a mixed-use commercial and residential development with a minimum of one floor of commercial development above the ground floor. b. The property shall contain a mix of studio or 1 bedroom units, 2 and 3-bedroom units, and there shall be no dwelling units with more than 3 bedrooms. c. No more than 30% of the dwelling units shall contain 3 bedrooms. d. The building shall be a minimum height of 7 stories. e. A parking requirement will be calculated for all dwelling units within the development based on the parking requirements of the CB-5 zone, pursuant to Title 14, Chapter 5, Article A, of the Iowa City Code, entitled "Off Street Parking and Loading Standards." Prior to issuance of an occupancy permit for the building or buildings to be constructed on the property, payment of parking facility impact fees will be made to the City for dwelling units for which on-site parking is not provided. The amount of the fee for each required parking space not provided on-site shall be computed in the manner set forth in sections 14-7B-7(C) and 14-7B-7(F) of the City Code. Payment, deposit, use and refunds of fees shall be governed by sections 14-7B-8, 14-7B-9 and 14-7B-10 of the City Code. f. The building shall be set back a minimum of 10-foot from the Burlington Street right- of-way. This 10-foot setback applies to the upper floors of the building as well as the ground floor. Bays may project up to 6 feet into the setback. g. The applicant shall grant a public access easement across the entire 10-foot walkway/setback along Burlington Street to assure maintenance and snow removal. h. The applicant shall provide landscaping and streetscape improvements, including textured paving materials, plantings, and street furniture as approved by the City. This includes construction and installation of the streetside landscaping within the Burlington right-of-way. i. Substantial compliance with the site plan submitted. The design of the development must be approved by the Design Review Committee. The owner and Developer must demonstrate to the satisfaction of the Design Review Committee how the proposed street-level fa9ade will meet the following standards: · The plane of the building at the street-level must be broken into vertical modules that give the appearance of smaller, individual storefronts reflective of the pattern and character found in downtown Iowa City. Each module must be no greater than 50 feet and no less than 20 feet in width and must be distinguished from the abutting module(s) by a significant and visible change in building materials and a variation in the wall plane of at least 16 inches. Changes in material colors and textures and other architectural detailing should be used to enhance this effect. 7 -To create a human-scaled environment that is comfortable and attractive to pedestrians, awnings and/or canopies must be used to enhance the storefront modules. -Pedestrian entrances must be attractive and inviting features along the street-level and must be architecturally emphasized in a manner that is reflective of the pattern and character found in downtown Iowa City. ATTACHMENTS: 1. Location Map 2. Elevations, Drawings, and Diagrams Approved by: ~~ Robert Miklo, Senfor Planner, Department of Planning and Community Development ppdadminlstfrepltemplate. doc \__J l1 !l t: t3 ~ ~ L_ __^~ ~ ,-,~~ ~ ^" ~I ~ \.3 ,... c.. Ii I I I -==m"m --.Ii:: ~ ~ :E a: C]j en =:s Q UJ: co o o o o I I"- o N W a: of-' Cf) Q) ::J cr ::J .0 ::J o Cf) ~ o Cf) . . Z o ~ ~ U o ~ ~ ~ ~ cJ) /'--"', / \ ~~ , / '- / o C\J ,.- I- (j) Z 2i i CJ I I II ~ :=' '~,~ .c~~ ~ t c ~[' ~ ~~ ~ ]' a (/ --"'j - 1- ffi ~ a \ I ~ I tl. ' ,>> ,e{'r" . . 'r~'1 j (-') . \,_.., b , b 0 <.0 <0 II - ,.... 0 W C'1 -l <( 0 0 (f) i I I ---.....===c \ j ~ \ .n..... ~m..m \ r~ QO@ @(j) @ @~ @~ !@@ @(j) L. "',"1 8 _-n----.---.-----.-m-.......-n-.~..... /,,,/.-'" (/D. 0, : 81 I'-- :-----. 0 0 C\J - C'0 T""" >- ./ -' J''"'' =:l J Z :5 0.... W I- (j) '18 N01NIl8 f r i~ \ I I r1 r- r- " ----1 --i - ,.--- ----1 --i - ~ ~ f- - '-- r- - - r- - l- e- - iT I I I II I I I I I I II I I I I I I I I I I I II .L '-- r--, -' ~ - - IT-:- I - f- H-T- I - r- I ~ ~ t-r: '=='" -' ~ - '::: + ~ - H- I - - I '==, Il I I I I I I _I - II II " II I" F -<I Iff 11 II II II I Ii I ~ n II II II II II II I l- I l- I . II II II II II II III II II I" II II II III I II II I I ! I . I II II II II - n ... II II I g~ fT ;::pr [I II II II III 1 I s: , I / I I I I I I I I I I I J J I I ~ -- - - - - - - - ---- I I z 0 ~ ::> ill ....J ill t--= (f) z (/) 0 w l- I- Z <( U ....J w 0 cr:: ~ ::J <( (/) ca (/) ::J <( 0 (/) W ~ (/) <( ::J ::J 0 0 :::E (/) >- (/) Z 0 ::J ~ 0 w :::E >- :x: z 0 ~ w :x: 51 I- Z w :::E z Q. 0 0 ...J I- W Cl > z w ....J ...J Cl g 51 ~ ::J (/) lD ...J ...J ~ ::J ca co 0 ::J (") w (f) w C9 ~ :x: Z I- ~5 51 -N 00 ~Z/'- <{o QC9~ u..~o OZ..... ~~~ Uo..~ S OC/) Of- zo:: -0 So.. >-0.. <l:=> COC/) C/) UJ 0:: f-f- <l:Z UJ ~C> -Z 0..- 00 Z:::! <l:=> Uco -l <l: 0:: UJoo f-Z <l:- ~Z UJQ =>~ 0_ ~o:: O~ UJ 0:::0::: O=> -l~ UJOUJUJ ZUf-~ :S<i!<i!~C/) o..c::c::o::<i! -lUJUJOUJ -If-f-U> ~<l:c(UJUJ >~~OO::: I I I I C/) f- Z 00 UJO::: C/)u. C/)UJ UJO::: UO UJf- O::C/) Z o ~ ~W W> ---II- wO .W 1-0... en en zO::: OW 1-0... (90::: zw ::JZ 0:::0::: ::>0 [DC) f- Z UJ O::-l ~::f C/)O::: ZUJ <l:~ g:~ -l <l:f- c::Z UJUJ C/) ~aJ UJ ~-lf-O::: o..Z=> UJ~UJf- =>OUU OU<l:=> <l: ...,0::: 0..00f- 0f-<l:C/) ---I ~ I- ~ [D ::> CJ) (9 z >-z 1-0 -N C)o ~Z/'-- ><(0 QC9~ I..i...~c:i Oz...... >-z>- 1-<(---1 ----I::> C)o......., ~ FFl82.tOO I (1~0"l I " ; . $'~~EI.~IOO ~ I I (141'-()'] ~ . ~ 4 I $';~d,~;~ ~oo CONDO (1:l2'../)') I I I " I b I $':~Hf~~\./ -oJ ~oo CONDO (122'.q) I I ~ II $'~~~I ~1(Jr ~ ~OO (112'-<1'1 I I ~ , I I~ $'~~H~';'~~r.i .... ~DO CONDO I~ l!02'.()") I I ~ (/) I I(/) <( $ ~:~l~~__ ~oo CONDO I IV-O"l I I ~ I $ :~HEL;:~_~ ~oo (fl<"..(l") I I 15'..(1' EXISTING COUfIT ST, MMP ; ; r-~=WWALL $ ;:~~.~~'(Xi~ ~oo CONDO ~z.<n I b ~ TOPTIER,CT 51 RAVP $ :~H~L~~~ --: ~oo CONDO (62'..(YI I . ,,-:<:::JO~, " ~ ~~ $ :T:~I ~~l()/ --: ~DO CONDO ('?-<l'! II ~ ; / EXISTING WAll i $ :~jEt~,v;,IOO' --: ~oo CONDO 14}"Q') 1: , , IIi ;;:~t; , f ~ n '1~ ';"'1 \~,~'h I .' $ ~~:;~. --: ~ICE_ '1: OFFICE " ''''<n . '~i! ~ " ~{ ,,;~;, " , ~ 1" ~. $;::I:n~~.~ ~- OFFICE (1~'{l') ,I ; ~ em.; RETAIL rrc.66J.oo '.<n " , $ ~~~:;I~l BASfMfNT BASEMENT (-1241 I I "NI' CITY OF IOWA CITY PLANNING AND ZONING SUBMITTAL JULY 13, 2007 F.~,~j~;;; ~ (6J'.a"1 F}~f~~~~ (57-41 ~ ~ (n-o'j FrE~;~~ (29'-81 "~OtF'i"Fl~ FFE70233 (18'''' ~~~~~~~ ,..., BUILDING SECTION DUBUQUEST. 50'-0' ~ ~ ~ ~ ~ ~ ~ ~ ~ N f- Cf) Z 0 f- 9 C) @ ~ Z ~ --.J TENANT 0: ~ ~ 9 - '" 4,944 SF en N ~ 9 '" N ~ } --, I InIJ} I~ iJ a:: UJ f- Z UJ U Z o ~ f- a:: o a... (f) z Cf f- r..: (f) f- a:: ~ o u C9 z 1= (f) X UJ ,~ ~8 N C") b -' ,- (0 II (0 ,- - ,- Co W --.J <( o U) o r- --.J W > W --.J /'-- o o C\J C") --.Jr- ~:::J W~ O:J DUBUQUEST. Z68 C\J (V) b - I T""" II Co (0 T""" - T""" Co W --.J <( 0 Cf) 0 r- I I I I I I ~ \ \ \ \ \ \ L_ o a: UJ f- Z UJ o Z o ~ a: o 0... (/) Z ~ f- ~ (/) f- a: ::J o o CJ z f= (/) X UJ I- r- I Cf) I Z I I 0 I 0 I I- ~ C) Z \ TENANT \ ---1 \ - a: \ 6,098 SF \ ~ \ CO L_ 0 r- I I I I I I ~ \ \ \ \ \ \ L_ o !~ ~ .[i CY) C\J ---1 W >f"-.. Wo ---10 C\J WC'0 0"- ->- LL---1 LL~ OJ DUBUQUE 8T. ~8 50'-0" N "'[:8J""[:8J C') (:) - I ,.- II (0 Co ,.- - ,.- Co W ---l '=:t 0 <( , Lo 0 N Cf) 0 UNIT 9 af Ud} Lo - N 1,635 SF 0::: llJ f- Z C? llJ U '=:t Z N 0 ~ f- UNIT 0 0::: , 0 Lo Q.. 1,141 SF N Cf) f- z U) r!f z f- t---= 0 Cf) f-b f- 0::: C)6 ::> Z~ 0 u --.J <!) 0: z UNIT 0 . . i= ~ , Cf) Lo X CO 1 ,141 SF N llJ UNIT 1,896 SF o I Lo N o - 0 1~ t~ ~ (0 LO .;;t --.J W >J".... Wo --.JO I C\J OM OT""" Z~ O~ OJ ~ DUBUQUEST. 50'-0" t - p T~"'~: ~5'-6" -- -- - -, ~ ~ Lr - '=:-1<= 0 ~I\ Lh 1<= 15 '-0" , C\J ~~ UNIT - 1,453 SF (+ 345 sf 8th LEVEL) ~ - ~ II - Co - 7 - ~Z , V' '=:- C\J ~. a: -T~ UNIT ~ - " 928 SF 0 (+ 350 sf 8th LEVEL) 0 II - -" - r-- , c:: - ~ - ROO GA mE UNIT ,727 s - 928 SF (+ 350 sf 8th LEVEL) ~ - II - i""'" -:7 V -- k UNIT - 928 SF (+ 350 sf 8th LEVEL) - - - - - '7 - ~ c:: ~ UNIT - /' 677 SF (+212sf 1IIIIIIII 8th LEVEL) L/ I b - f- (j) Z o f-b C)o z~ .-J a: ~ co ~8' C\J C') b - I ,..... II (0 ,- Co ,..... - ,..... OJ W .....J <x:: 0 0 (/) :s: o ....J UJ (l) a: UJ r- z UJ u z o ~ r- a: o Cl.. en z ~ r- ~ en r- a: :::> o u " z i= en x UJ 2 (j) I f- a T"'"" f'-... .-J W >f'-... wa .-Ja IN OC'0 0"""" Z:::J O~ UJ DUBUQUEST. -t 50'-0" } I- if) z o I- 9 CD b Z ~ --.J 0: ::" OJ p- ~cg] cg]' 5'-6" n .. UNIT \: -- - ~ , ilj 8 - Li '" 439 SF (+ 515 sf 'r 9th LEVEL) - lo - '= 15'-0" N Ii UNIT UNIT " \\ - - 409 SF 345 SF (+ 928 sf (+ 1453 sf 9th LEVEL) 7th LEVEL) or - '=t ..... '= "7 N UNIT ~ , n UNIT :3 - - , 409 SF 350 SF w (+ 928 sf (+ 928 sf L.l.J 9th LEVEL) 7th LEVEL) ~ 0 "" - 9; 0; \: "7 C) LL \J 0 UNIT a: \f= UNIT- - - 409 SF 350 SF (+ 928 sf (+ 928 sf 9th LEVEL) 7th LEVEL) - - -\:: "7 - fF= UNIT UNIT - - 409 SF 350 SF (+ 928 sf (+ 928 sf 9th LEVEL) 7th LEVEL) ..". - "i - \: 7 UNIT UNIT - - 212 SF ~ 402 SF (+ 677 sf (+761 sf 7th LEVEL 9th LEVEL) LJ 0 ~8 N (V) b - I ..- (0 II ..- (0 ..- - ..- Co W -l <( 0 0 U) ~ o .-J UJ en a: UJ f- Z UJ o Z o ~ f- a: o a.. Cf) z ~ f- ~ Cf) f- a: => o o CJ z r= Cf) x UJ ~ if) I I- -r- -r- co --.J W >1"-- Wo --.JO IN OC'0 O~ Z~ 0::" OJ DUBUQUEST. 50'-0" 1/ J P H~ ~t 5'-6" - -- -- , n ' ~ '" UNIT ill 8 - IT - a: 515 SF (+ 439 sf 8th LEVEL) ~ - , Ln - C\J UNIT - I' \\ 928 SF ::.:: () w (+ 409 sf 8th LEVEL) _ID ro I -D ~ C\J ::.:: () w ~ 0 , n UNIT ~ - W " 928 SF --u..r (+ 409 sf 8th LEVEL) as 0 .-J - ~ '" c.9 !:!:: 0 a: F UNIT - 928 SF ::.:: () (+ 409 sf 8th LEVEL) j - -I - =z () w UNIT 0 F - 928 SF (+ 409 sf 8th LEVEL) - - .-J ~ - ::.:: "- UNIT () w - 0 761 SF (+ 402 sf 8th LEVEL) , b I- (J) Z o I-b C)6 Z~ --.J 0: :J CO ~8 N (V) b - I T""" II (0 Co T""" - T""" ro W ---1 <( 0 0 if) 3: o ...J W CD 0: W I- Z W () Z o ~ ~ o 0.. Cf) Z ~ I- ~ Cf) I- 0: ::J o () CJ z i= Cf) ~ L (J) I l- N .,..- C) --.J W >1"-- Wo --.JO IN 0(") 0""- Z~ O:J OJ ~ CJ) z o f-b (9 6 _I Z LO 0 ..- LO ~ 0: :::) CO , 1 ~ ti:i o l UNIT: _I 843 SF : 1 1 1 _____J --, 1 1 1 1 1 1 1 o 1 1 I UNIT: _I. 810 SF: 1 I _____J --, 1 1 UNIT: -I 806 SF 1 1 o 1 I 1 1 1 1 1 1 1 1 _____J DUBUQU 50'-0" E 81. ~8 ~ w CD u.. o o 0:: II o -' .- UNIT: _I 345 SF : 1 1 1 L___ 00 o r--- 1 1 1 1 1 I I UNIT: _I 697 SF L__ ~ W > W ~ W CJ) :::) o I f- Z wI'-- 0....0 o IN Oc0 0""'- Z~ 0:::) UJ ('I') ,....- UNIT r-- _I 562 SF I I I 1 1 1 1 1 1 L___ City of Iowa City MEMORANDUM July 19, 2007 To: Planning and Zoning Commission From: Karen Howard, Associate Planner Re: Comprehensive Plan Amendment for the Northeast District In addition to the amended plan map that we sent to you last week, we suggest adding the following paragraphs to the Northeast District Plan to provide some context for the changes to the map. The plan map for the Lindemann Hills Neighborhood was revised in 2007 to provide the opportunity for a large institutional use, a church, to locate north of the public square along Lower West Branch Road. The principles adopted with the original plan remain intact, including the public square as a neighborhood focal point, interconnected streets extending from the four corners of the public square, with sidewalks and trail connections that ensure good vehicular, pedestrian, and bicycle circulation between residences, the public square, and other important neighborhood destinations, such as neighborhood commercial areas and the linear open space along the stream corridors that flow north-south along both the eastern and western edges of the neighborhood. The revised map illustrates how this large institutional use can be integrated successfully into future residential neighborhoods that will surround the church. A trail connection across the center of this large property will insure a means of east-west travel through the neighborhood. Future annexation and development of property north of the church property should include a street to provide a second means of access for the church, which will help to disperse traffic. Open spaces within residential areas should be visible and accessible to the public. Single-loaded streets along park edges and conveniently located mid-block trail connections are strongly encouraged so that all neighborhood residents are within walking distance of parks and open space and so that the trail system can be used as a means of traveling around and through the neighborhood. This principle is particularly important for medium density development, such as townhouses and multi-family, where the amount of private open space is limited. Suggested locations for medium density residential uses, such as townhouses and multi- family are noted on the plan map, however, there may be other locations that may be suitable for these housing types, such as along single loaded streets across from parks, close to neighborhood commercial areas and along arterial street corridors. The remaining area is suitable for single family homes. Collector streets built with rear alleys for vehicular access will allow for smaller, more affordable home lots and increase traffic safety on this higher volume streets. As with the revised plan map sent to you last week, the text suggested above is a draft and can be modified based on your review and public input. 2